Nowadays, increased human activity, industrialization, and urbanization result in the production of enormous quantities of wastewater. Generally, physicochemical and biological methods are employed to treat industrial effluent and wastewater and have demonstrated high efficacy in removing pollutants. However, some industrial effluent and wastewater contain contaminants that are extremely difficult to remove using standard physicochemical and biological processes. Previously, electrochemical and hybrid advanced oxidation processes (AOP) were considered a viable and promising alternative for achieving an adequate effluent treatment strategy in such instances. These processes rely on the production of hydroxyl radicals, which are highly reactive oxidants that efficiently break down contaminants found in wastewater and industrial effluent. This review focuses on the removal of contaminants from industrial effluents and wastewater through the integration of electrochemical and advanced oxidation techniques. These processes include electrooxidation, electrocoagulation/electroflocculation, electroflotation, photo‐Fenton, ozone‐photo‐Fenton, sono‐photo‐Fenton, photo‐electro‐Fenton, ozone/electrocoagulation, sono‐electrocoagulation, and peroxi/photo/electrocoagulation. The data acquired from over 150 published articles, most of which were laboratory experiments, demonstrated that the hybrid process is more effective in removing contaminants from industrial effluent and wastewater than standalone processes.
During the last two decades, there has been an increase in interest the use of electrochemical and advanced oxidation technologies for treatment of industrial wastewater. Efficacy of several techniques for treating distilling industry wastewater (DIW), UV light, H2O2, combination of UV and H2O2, direct current (DC) and alternating current (AC)‐electro‐Fenton (EF), and UV combined with DC/AC+EF (UV+DC/AC+EF) processes were all examined. The findings revealed that compared to the UV, H2O2, UV/H2O2, DC/AC+EF, and UV+DC+EF technologies, the UV+AC+EF process resulted total color of 100 % and COD of 100 % elimination efficiency with low energy use 4 kWhr m−3. A response surface methodology (RSM) approach that relies on central composite design (CCD) was used to optimize the UV+AC+EF technology‘s parameters for treating DIW. Optimal conditions were obtained by utilizing mathematical and statistical methods in order to maximize COD elimination (89.50 %) and minimize energy consumption (2.775 kWhr m−3). The parameters for this experiment were as follows: UV power: 32 W, H2O2: 320 mg L−1, COD: 2400 mg L−1, CD: 0.2 A dm−2, and duration: 111 min. The combined efficiency of removing % COD using the UV, AC+EF, and UV+AC+EF processes was used to determine the synergistic effect, which was 13.65 %. As a consequence of this, treating industrial wastewater with a hybrid UV+AC+EF technique is significantly more successful.
Distillery industrial wastewater (DIW) was tested for color and COD removal percentages using an electrochemical and advanced oxidation processes (AOPs). Specifically, the study compared direct/alternating–current–electrocoagulation (DC‐EC/AC‐EC), sono (US), and direct/alternating current–electrocoagulation coupled with sono (US) (DC‐EC/US and AC‐EC/US) processes. Also evaluated were the effects of these procedures on the power needed to treat DIW. Experimental results showed that compared to single processes such as DC‐EC, AC‐EC, US, hybrid DC‐EC/US, and the hybrid AC‐EC/US process achieved a total color elimination efficiency of 100 % and a COD elimination efficiency of 100 % while using a lower power consumption of 4.76 kWhrm−3. The effects of important operational factors such treatment duration, cycle of pulse duty, sonication power, current density, chemical oxygen demand, electrode spacing, electrode pairing, pH, concentration of electrolyte on the % removal of COD and power usage of DIW were investigated using hybrid AC‐EC/US process. When using a Fe/Fe electrode combination, the effectiveness of COD removal was shown to be enhanced by increasing the treatment duration, current, US power, and decreasing the COD concentration, electrode spacing. The study also provided the results of an investigation into the synergistic index between AC‐EC and US process and operational cost. Based on its ability to efficiently and effectively remove contaminants from wastewater and industrial effluent, the AC‐EC/US approach stands out among the other methods.
Regional information on stream discharge is needed in order to improve flood estimates based on the limited data availability. Regional flood estimation is fundamental for designing hydraulic structures and managing flood plains and water resource projects. It is essential for estimating flood risks during recurrent periods due to suitable distributions. Regional flood frequency analysis is crucial for evaluating design flows in ungauged basins, and can complement existing time series in gauged sites and transfer them to ungauged catchments. Hence, this study aims to perform a regional flood frequency analysis of the Genale–Dawa River Basin of Ethiopia using the index flood and L-moments approach for sustainable water resource management. Three homogeneous hydrological regions were defined and delineated based on homogeneity tests from data of 16 stream-gauged sites, named Region-A, Region-B, and Region-C. The discordancy index of regional data for L-moment statistics was identified using MATLAB. All regions showed promising results of L-moment statistics with discordance measures (discordance index less than 3) and homogeneity tests (combined coefficient of variation (CC) less than 0.3). L-moment ratio diagrams were used to select best fit probability distributions for areas. Generalized extreme value, log-Pearson type III, and generalized Pareto distributions were identified as suitable distributions for Region-A, Region-B, and Region-C, respectively, for accurately modeling flood flow in the basin. Regional flood frequency curves were constructed, and peak flood was predicted for different return periods. Statistical analysis of the gauged sites revealed an acceptable method of regionalization of the basin. This study confirms that the robustness of the regional L-moments algorithm depends on particular criteria used to measure the performance of estimators. The identified regions should be tested with other physical catchment features to enhance flood quantile estimates at gauged and ungauged sites. Henceforth, this study’s findings can be further extended into flood hazard, risk, and inundation mapping of identified regions of the study area. Furthermore, this study’s approach can be used as a reference for similar investigations of other river basins.
In recent years, there has been a rise in the use of electrochemical and advanced oxidation methods to treat the industrial wastewater. The efficiency of several approaches for treating industrial wastewater, including hydrogen peroxide (H 2 O 2 ), electro–Fenton (EF) and pulsed–electro–Fenton (PEF) processes were all investigated. In evaluation to the H 2 O 2 , EF, and PEF technologies, the results showed that the PEF process produced 100 % total color and 98 % chemcial oxygen demand (COD) removal efficiency with a low consumption of power of 3.4 kWhrm −3 . The experimental parameters comprised the following: COD – 2500 mg L −1 , pH – 3, H 2 O 2 – 300 mg L −1 , distance between electrode – 0.75 cm, current – 0.40 A, cycle of pulse duty – 0.75, combination of electrode – Fe/Fe, stirring speed – 500 rpm and treatment duration (TD) – 125 min. It was demonstrated that increasing the TD, current, and H 2 O 2 while lowering the COD content improved the COD elimination efficiency while employing a iron (Fe/Fe) electrode combination with wastewater pH of 3. The efficiency of the EF process has been reduced in comparison to the PEF process because of the development of an impermeable oxide layer on the cathode and the oxidation–induced corrosion on the anode. Consequently, experimental results have indicated that the PEF could be a more promising technology than the EF method for eliminating pollutants from wastewater with reduced power consumption and process efficiency.