Marco Antonio Reyna

Dr. Marco Antonio Reyna

Universidad Autónoma de Baja California, Mexicali, Baja California, Mexico
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Relevant to mobile health, the design of a portable electrocardiograph (ECG) device using AD823X microchips as the analog front-end is presented. Starting with the evaluation board of the chip, open-source hardware and software components were integrated into a breadboard prototype. This required modifying the microchip with the breadboard-friendly Arduino Nano board in addition to a data logger and a Bluetooth breakout board. The digitized ECG signal can be transmitted by serial cable, via Bluetooth to a PC, or to an Android smartphone system for visualization. The data logging shield provides gigabytes of storage, as the signal is recorded to a microSD card adapter. A menu incorporates the device’s several operating modes. Simulation and testing assessed the system stability and performance parameters in terms of not losing any sample data throughout the length of the recording and finding the maximum sampling frequency; and validation determined and resolved problems that arose in open-source development. Ultimately, a custom printed circuit board was produced requiring advanced manufacturing options of 2.5 mils trace widths for the small package components. The fabricated device did not degrade the AD823X noise performance, and an ECG waveform with negligible distortion was obtained. The maximum number of samples/second was 2380 Hz in serial cable transmission, whereas in microSD recording mode, a continuous ECG signal for up to 36 h at 500 Hz was verified. A low-cost, high-quality portable ECG for long-term monitoring prototype that reasonably complies with electrical safety regulations and medical equipment design was realized.

DMDalia M. Muñoz-Pizza
Dalia M. Muñoz-Pizza
MARIANA VILLADA-CANELAMARIANA VILLADA-CANELA
MARIANA VILLADA-CANELA
MRMarco Antonio Reyna
Marco Antonio Reyna
JSJosé Luis Texcalac Sangrador
José Luis Texcalac Sangrador
JSJesus Serrano-Lomelin
Jesus Serrano-Lomelin
AVAlvaro Osornio Vargas
Alvaro Osornio Vargas
Air pollution in developing countries is a growing concern. It is associated with urbanization and social and economic structures. The understanding of how social factors can influence the perception and the potential impact of air pollution have not been addressed sufficiently. This paper addresses the social vulnerability and exposure to PM10 association and its influence on the air quality perception of residents in Mexicali, a Mexico–US border city. This study used individual variables and population census data, as well as statistical and spatial analyses. A cluster of socially vulnerable populations with high exposure to coarse particulate matter (PM10) was found in the city’s peripheral areas. The spatial distribution of the local perception of air quality varied by the exposure zones of the estimated PM10 concentrations. Respondents living in very high exposure areas perceive air quality as “poor,” contrarily to a worse perception in areas of intermediate and lower exposure to PM10. Proximity to stationary sources of pollution was associated with a poor perception of air quality. Results also indicate that low household income and poor air quality perceived at the place of residence negatively influences the perceived changes in the air quality over time. The knowledge of chronic health effects related to air pollution was scarce in the sampled population, especially in the areas with very high exposure and high social vulnerability. These findings can serve as a support in local air quality management.

Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
MGMaria Luisa Gonzalez
Maria Luisa Gonzalez
Interoperability is defined as the ability of a system or device to communicate between different technologies and software applications. This allows the exchange and use of data in an efficient, precise, and robust way. The present article gives researchers and healthcare information systems developers a qualitative and quantitative synthesis of the state of knowledge related to data formats and data standards proposed for mHealth devices interoperability in healthcare information systems that retrieve and store ECG data. We carry out a scoping review to answer to following questions: (1) What digital data formats or data standards have been proposed for the interoperability of electrocardiograph data between traditional healthcare information systems and mobile healthcare information systems? (2) What are the advantages and disadvantages of these data formats or data standards? The scoping review was conducted in four databases in accordance with the JBI methodology for scoping reviews, and in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). A total of 4018 studies were identified of which 30 studies met the inclusion criteria. Based on our findings, we identify four standards and nine formats for capturing and storing streaming ECG data in mobile health applications. The standards used were HL7, SCP-ECG, x73-PHD, and PDF/A. Formats include CSV, PDF-ECG, and seven XML-based formats. These are ECG-XML, HL7-XML, mPCG-XML, mECGML, JSON, SaECG, and CDA R2.

14 November 2019 in Proceedings
Verified
Conference Paper
Open access
PDF file
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
This paper presents the design of a portable electrocardiograph (ECG) device using the AD8232 microchip as the analog front-end (AFE). Starting with the manufacturer’s evaluation board of the AFE chip for testing circuit configurations, open-source hardware and software components were integrated into a breadboard prototype. Ultimately, a custom printed circuit board (PCB) was produced. The prototype required to accommodate the microchip on a SMD-to-DIP adapter for testing with the breadboard-friendly Arduino microcontroller alongside a data logger and a Bluetooth breakout board. The analog ECG signal from the AFE output was digitized using one channel of the 10-bit analog-to-digital Converter (ADC) of the ATmega328 microcontroller contained in the Arduino Nano board. The digitized ECG signal can be transmitted not only by serial cable using the Arduino functions, but also via Bluetooth to a PC or to an Android smartphone system when the HC-06 shield is used. The data logging shield provides gigabytes of storage, and the signal is recorded to a micro SD card adapter along with the date and time stamp data of the sample capture (real-time clock provided). In addition to hardware and software development, a simulation was used in the analog circuit design with SPICE Multisim software and the related macromodel library to assess system stability. Besides the analog filters in the AFE stage, digital filtering by means of simple difference equations was investigated. A menu was incorporated to choose from the several modes of operation of the device. The ECG test signals were obtained from a patient simulator (SimCube) and real patients. A portable ECG system for monitoring applications that complies with electrical safety regulations and medical equipment design was realized.

24 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SESharon Ezrre
Sharon Ezrre
MRMarco Antonio Reyna
Marco Antonio Reyna
RARosa Anguiano
Rosa Anguiano
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
HMHeriberto Marquez
Heriberto Marquez
Lab-on-a-Chip (LoC) devices are described as versatile, fast, accurate, and low-cost platforms for the handling, detection, characterization, and analysis of a wide range of suspended particles in water-based environments. However, for gas-based applications, particularly in atmospheric aerosols science, LoC platforms are rarely developed. This review summarizes emerging LoC devices for the classification, measurement, and identification of airborne particles, especially those known as Particulate Matter (PM), which are linked to increased morbidity and mortality levels from cardiovascular and respiratory diseases. For these devices, their operating principles and performance parameters are introduced and compared while highlighting their advantages and disadvantages. Discussing the current applications will allow us to identify challenges and determine future directions for developing more robust LoC devices to monitor and analyze airborne PM.

15 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MRMaría-Isabel Rocha-Gaso
María-Isabel Rocha-Gaso
Luis Jesús Villarreal-GómezLuis Jesús Villarreal-Gómez
Luis Jesús Villarreal-Gómez
Denis BEYSSENDenis BEYSSEN
Denis BEYSSEN
FSFrédéric Sarry
Frédéric Sarry
MRMarco Antonio Reyna
Marco Antonio Reyna
CICarlos Ibarra-Cerdeña
Carlos Ibarra-Cerdeña
Chagas disease (CD), which mostly affects those living in deprived areas, has become one of Latin America’s main public health problems. Effective prevention of the disease requires early diagnosis, initiation of therapy, and regular blood monitoring of the infected individual. However, the majority of the Trypanosoma cruzi infections go undiagnosed because of mild symptoms, limited access to medical attention and to a high variability in the sensitivity and specificity of diagnostic tests. Consequently, more affordable and accessible detection technologies capable of providing early diagnosis and T. cruzi load measurements in settings where CD is most prevalent are needed to enable enhanced intervention strategies. This work analyzes the potential contribution of biosensing technologies, reviewing examples that have been tested and contrasted with traditional methods, both serological and parasitological (i.e., molecular detection by PCR), and discusses some emerging biosensing technologies that have been applied for this public health issue. Even if biosensing technologies still require further research efforts to develop portable systems, we arrive at the conclusion that biosensors could improve the accuracy of CD diagnosis and the follow-up of patients’ treatments in terms of the rapidity of results, small sample volume, high integration, ease of use, real-time and low cost detection when compared with current conventional technologies.