Daniel Cuevas-González

Dr. Daniel Cuevas-González

Universidad Autónoma de Baja California
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
MGMaria Luisa Gonzalez
Maria Luisa Gonzalez
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Marcela D. RodríguezMarcela D. Rodríguez
Marcela D. Rodríguez
APAlfredo Padilla-Lopez
Alfredo Padilla-Lopez
GGGilberto Galindo
Gilberto Galindo
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
In recent years, wearable devices have been increasingly used to monitor people’s health. This has helped healthcare professionals provide timely interventions to support their patients. In this study, we investigated how wearables help people manage stress. We conducted a scoping review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) standard to address this question. We searched studies in Scopus, IEEE Explore, and Pubmed databases. We included studies reporting user evaluations of wearable-based strategies, reporting their impact on health or usability outcomes. A total of 6259 studies were identified, of which 40 met the inclusion criteria. Based on our findings, we identified that 21 studies report using commercial wearable devices; the most common are smartwatches and smart bands. Thirty-one studies report significant stress reduction using different interventions and interaction modalities. Finally, we identified that the interventions are designed with the following aims: (1) to self-regulate during stress episodes, (2) to support self-regulation therapies for long-term goals, and (3) to provide stress awareness for prevention, consisting of people’s ability to recall, recognize and understand their stress.

21 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Relevant to mobile health, the design of a portable electrocardiograph (ECG) device using AD823X microchips as the analog front-end is presented. Starting with the evaluation board of the chip, open-source hardware and software components were integrated into a breadboard prototype. This required modifying the microchip with the breadboard-friendly Arduino Nano board in addition to a data logger and a Bluetooth breakout board. The digitized ECG signal can be transmitted by serial cable, via Bluetooth to a PC, or to an Android smartphone system for visualization. The data logging shield provides gigabytes of storage, as the signal is recorded to a microSD card adapter. A menu incorporates the device’s several operating modes. Simulation and testing assessed the system stability and performance parameters in terms of not losing any sample data throughout the length of the recording and finding the maximum sampling frequency; and validation determined and resolved problems that arose in open-source development. Ultimately, a custom printed circuit board was produced requiring advanced manufacturing options of 2.5 mils trace widths for the small package components. The fabricated device did not degrade the AD823X noise performance, and an ECG waveform with negligible distortion was obtained. The maximum number of samples/second was 2380 Hz in serial cable transmission, whereas in microSD recording mode, a continuous ECG signal for up to 36 h at 500 Hz was verified. A low-cost, high-quality portable ECG for long-term monitoring prototype that reasonably complies with electrical safety regulations and medical equipment design was realized.

Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
MGMaria Luisa Gonzalez
Maria Luisa Gonzalez
Interoperability is defined as the ability of a system or device to communicate between different technologies and software applications. This allows the exchange and use of data in an efficient, precise, and robust way. The present article gives researchers and healthcare information systems developers a qualitative and quantitative synthesis of the state of knowledge related to data formats and data standards proposed for mHealth devices interoperability in healthcare information systems that retrieve and store ECG data. We carry out a scoping review to answer to following questions: (1) What digital data formats or data standards have been proposed for the interoperability of electrocardiograph data between traditional healthcare information systems and mobile healthcare information systems? (2) What are the advantages and disadvantages of these data formats or data standards? The scoping review was conducted in four databases in accordance with the JBI methodology for scoping reviews, and in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). A total of 4018 studies were identified of which 30 studies met the inclusion criteria. Based on our findings, we identify four standards and nine formats for capturing and storing streaming ECG data in mobile health applications. The standards used were HL7, SCP-ECG, x73-PHD, and PDF/A. Formats include CSV, PDF-ECG, and seven XML-based formats. These are ECG-XML, HL7-XML, mPCG-XML, mECGML, JSON, SaECG, and CDA R2.

14 November 2019 in Proceedings
Verified
Conference Paper
Open access
PDF file
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
This paper presents the design of a portable electrocardiograph (ECG) device using the AD8232 microchip as the analog front-end (AFE). Starting with the manufacturer’s evaluation board of the AFE chip for testing circuit configurations, open-source hardware and software components were integrated into a breadboard prototype. Ultimately, a custom printed circuit board (PCB) was produced. The prototype required to accommodate the microchip on a SMD-to-DIP adapter for testing with the breadboard-friendly Arduino microcontroller alongside a data logger and a Bluetooth breakout board. The analog ECG signal from the AFE output was digitized using one channel of the 10-bit analog-to-digital Converter (ADC) of the ATmega328 microcontroller contained in the Arduino Nano board. The digitized ECG signal can be transmitted not only by serial cable using the Arduino functions, but also via Bluetooth to a PC or to an Android smartphone system when the HC-06 shield is used. The data logging shield provides gigabytes of storage, and the signal is recorded to a micro SD card adapter along with the date and time stamp data of the sample capture (real-time clock provided). In addition to hardware and software development, a simulation was used in the analog circuit design with SPICE Multisim software and the related macromodel library to assess system stability. Besides the analog filters in the AFE stage, digital filtering by means of simple difference equations was investigated. A menu was incorporated to choose from the several modes of operation of the device. The ECG test signals were obtained from a patient simulator (SimCube) and real patients. A portable ECG system for monitoring applications that complies with electrical safety regulations and medical equipment design was realized.

23 April 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
AVAlvaro Osornio Vargas
Alvaro Osornio Vargas
Air pollution is caused by the presence of polluting elements. Ozone (O3), carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), sulfur dioxide (SO2), and particulate matter (PM) are the most controlled gasses because they can be released into the atmosphere naturally or as a result of human activity, which affects air quality and causes disease and premature death in exposed people. Depending on the substance being measured, ambient air monitors have different types of air quality sensors. In recent years, there has been a growing interest in designing drones as mobile sensors for monitoring air pollution. Therefore, the objective of this paper is to provide a comprehensive patent review to gain insight into the proprietary technologies currently used in drones used to monitor outdoor air pollution. Patent searches were conducted using three different patent search engines: Google Patents, WIPO’s Patentscope, and the United States Patent and Trademark Office (USPTO). The analysis of each patent consists of extracting data that supply information regarding the type of drone, sensor, or equipment for measuring PM, the lack or presence of a cyclone separator, and the ability to process the turbulence generated by the drone’s propellers. A total of 1473 patent documents were retrieved using the search engine. However, only 13 met the inclusion criteria, including patent documents reporting drone designs for outdoor air pollution monitoring. Therefore, was found that most patents fall under class G01N (measurement; testing) according to the International Patents Classification, where the most common sensors and devices are infrared or visible light cameras, cleaning devices, and GPS tracking devices. The most common tasks performed by drones are air pollution monitoring, assessment, and control. These categories cover different aspects of the air pollution management cycle and are essential to effectively address this environmental problem.

25 March 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
MRM. O. Rivera-García
M. O. Rivera-García
MRMarco Antonio Reyna
Marco Antonio Reyna
MCMario Camarillo
Mario Camarillo
MRM. A. Reyna-Vargas
M. A. Reyna-Vargas
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
AVAlvaro Osornio Vargas
Alvaro Osornio Vargas
Currently, air pollution is a critical public health problem, which means that the daily measurement of urban air quality can be enriched if measured in a personalized way. Personal environmental monitoring devices can guide the population to take action. They can track their daily activities, avoiding situations that could affect their health, allowing them to precisely know the air quality they breathe in real-time in various microenvironments. In this work, we present a review of cyclonic separation technology patents, such as pre-separators in monitoring devices. We focused on the state-of-the-art commercially available personal monitoring devices, the classification of kinds of patents, and a review of cyclone patents and gas–particle separation behaviors. The World Intellectual Property Organization IP’s portal and Google Patents search engine were used, using international patent classification plus mesh terms involving a cyclone in an air particulate monitor after predefining inclusion and exclusion criteria such as gas–air cyclones, high efficiency, and fine particle separation. Twenty-nine patents were analyzed according to the main characteristics (e.g., cut point, flow rate, and cyclone improvement) available in the patent document. The wide range of cyclones indicates a maximum flow rate of between 0.5 and 4.5 Lpm and a lower cyclone cut point of 0.8 μm. This review includes a discussion of the most relevant features of the patent documents (flow rate, particle cut point, some cyclone improvements, and technology detection). This paper aims to give an overview of the use of cyclones as pre-separators for personal air monitoring devices and to acknowledge the patented improvements of new inventors or developers.