Maximiliano Bueno-Lopez

Dr. Maximiliano Bueno-Lopez

University of Cauca, Popayán, Cauca, Colombia
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
EBEfrain Bernal
Efrain Bernal
MBMaximiliano Bueno-Lopez
Maximiliano Bueno-Lopez
JXJian Xie
Jian Xie
KSKai Strunz
Kai Strunz

27 November 2020 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
MRMiguel Angel Rodriguez
Miguel Angel Rodriguez
JSJohn Felipe Sotomonte
John Felipe Sotomonte
JQJenny Alexandra Cifuentes Quintero
Jenny Alexandra Cifuentes Quintero
MBMaximiliano Bueno-Lopez
Maximiliano Bueno-Lopez

2 November 2018 in Frontiers in Integrative Neuroscience
Verified
Journal Article
Open access
PDF file
PGPablo Andres Muñoz Gutiérrez
Pablo Andres Muñoz Gutiérrez
EGEduardo Giraldo
Eduardo Giraldo
MBMaximiliano Bueno-Lopez
Maximiliano Bueno-Lopez
MMMarta Molinas
Marta Molinas
The localization of active brain sources from Electroencephalogram (EEG) is a useful method in clinical applications, such as the study of localized epilepsy, evoked-related-potentials, and attention deficit/hyperactivity disorder. The distributed-source model is a common method to estimate neural activity in the brain. The location and amplitude of each active source are estimated by solving the inverse problem by regularization or using Bayesian methods with spatio-temporal constraints. Frequency and spatio-temporal constraints improve the quality of the reconstructed neural activity. However, separation into frequency bands is beneficial when the relevant information is in specific sub-bands. We improved frequency-band identification and preserved good temporal resolution using EEG pre-processing techniques with good frequency band separation and temporal resolution properties. The identified frequency bands were included as constraints in the solution of the inverse problem by decomposing the EEG signals into frequency bands through various methods that offer good frequency and temporal resolution, such as empirical mode decomposition (EMD) and wavelet transform (WT). We present a comparative analysis of the accuracy of brain-source reconstruction using these techniques. The accuracy of the spatial reconstruction was assessed using the Wasserstein metric for real and simulated signals. We approached the mode-mixing problem, inherent to EMD, by exploring three variants of EMD: masking EMD, Ensemble-EMD (EEMD), and multivariate EMD (MEMD). The results of the spatio-temporal brain source reconstruction using these techniques show that masking EMD and MEMD can largely mitigate the mode-mixing problem and achieve a good spatio-temporal reconstruction of the active sources. Masking EMD and EEMD achieved better reconstruction than standard EMD, Multiple Sparse Priors, or wavelet packet decomposition when EMD was used as a pre-processing tool for the spatial reconstruction (averaged over time) of the brain sources. The spatial resolution obtained using all three EMD variants was substantially better than the use of EMD alone, as the mode-mixing problem was mitigated, particularly with masking EMD and EEMD. These findings encourage further exploration into the use of EMD-based pre-processing, the mode-mixing problem, and its impact on the accuracy of brain source activity reconstruction.

28 February 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
ASAndres Soler
Andres Soler
PMPablo A. Muñoz-Gutiérrez
Pablo A. Muñoz-Gutiérrez
MBMaximiliano Bueno-Lopez
Maximiliano Bueno-Lopez
EGEduardo Giraldo
Eduardo Giraldo
MMMarta Molinas
Marta Molinas
Several approaches can be used to estimate neural activity. The main differences between them concern the a priori information used and its sensitivity to high noise levels. Empirical mode decomposition (EMD) has been recently applied to electroencephalography EEG-based neural activity reconstruction to provide a priori time-frequency information to improve the estimation of neural activity. EMD has the specific ability to identify independent oscillatory modes in non-stationary signals with multiple oscillatory components. However, attempts to use EMD in EEG analysis have not yet provided optimal reconstructions, due to the intrinsic mode-mixing problem of EMD. Several studies have used single-channel analysis, whereas others have used multiple-channel analysis for other applications. Here, we present the results of multiple-channel analysis using multivariate empirical mode decomposition (MEMD) to reduce the mode-mixing problem and provide useful a priori time-frequency information for the reconstruction of neuronal activity using several low-density EEG electrode montages. The methods were evaluated using real and synthetic EEG data, in which the reconstructions were performed using the multiple sparse priors (MSP) algorithm with EEG electrode montages of 32, 16, and 8 electrodes. The quality of the source reconstruction was assessed using the Wasserstein metric. A comparison of the solutions without pre-processing and those after applying MEMD showed the source reconstructions to be improved using MEMD as a priori information for the low-density montages of 8 and 16 electrodes. The mean source reconstruction error on a real EEG dataset was reduced by 59.42 and 66.04% for the 8 and 16 electrode montages, respectively, and that on a simulated EEG with three active sources, by 87.31 and 31.45% for the same electrode montages.

9 August 2023 in Entropy
Verified
Journal Article
Open access
PDF file
ARAngel H. Rangel-Rodriguez
Angel H. Rangel-Rodriguez
David Granados-liebermanDavid Granados-lieberman
David Granados-lieberman
Juan P. Amezquita-SanchezJuan P. Amezquita-Sanchez
Juan P. Amezquita-Sanchez
MBMaximiliano Bueno-Lopez
Maximiliano Bueno-Lopez
Martin Valtierra-RodriguezMartin Valtierra-Rodriguez
Martin Valtierra-Rodriguez
Currently, renewable energies, including wind energy, have been experiencing significant growth. Wind energy is transformed into electric energy through the use of wind turbines (WTs), which are located outdoors, making them susceptible to harsh weather conditions. These conditions can cause different types of damage to WTs, degrading their lifetime and efficiency, and, consequently, raising their operating costs. Therefore, condition monitoring and the detection of early damages are crucial. One of the failures that can occur in WTs is the occurrence of cracks in their blades. These cracks can lead to the further deterioration of the blade if they are not detected in time, resulting in increased repair costs. To effectively schedule maintenance, it is necessary not only to detect the presence of a crack, but also to assess its level of severity. This work studies the vibration signals caused by cracks in a WT blade, for which four conditions (healthy, light, intermediate, and severe cracks) are analyzed under three wind velocities. In general, as the proposed method is based on machine learning, the vibration signal analysis consists of three stages. Firstly, for feature extraction, statistical and harmonic indices are obtained; then, the one-way analysis of variance (ANOVA) is used for the feature selection stage; and, finally, the k-nearest neighbors algorithm is used for automatic classification. Neural networks, decision trees, and support vector machines are also used for comparison purposes. Promising results are obtained with an accuracy higher than 99.5%.

1 September 2019
Verified
Conference Paper
Closed access
MRMiguel Angel Rodriguez
Miguel Angel Rodriguez
JSJohn Felipe Sotomonte
John Felipe Sotomonte
JCJenny Cifuentes
Jenny Cifuentes
MBMaximiliano Bueno-Lopez
Maximiliano Bueno-Lopez
Disturbances in power quality have increased due to the use of electronic equipment, causing deviations in current and voltage waveforms, which can cause many failures and damage to equipment used in different demand points. Therefore, an efficient disturbance detection method is required in order to provide relevant information regarding its ocurrence. However, there are many difficulties detecting disturbances throughout traditional data extraction methods. These methods have not been able to perform the detection process with the efficiency, speed and accuracy required for this type of work, due to the non-stationary and non-linear behavior of these disturbances. In this study, the Hilbert-Huang Transform and the Multilayer Perceptron Neural Network model are implemented in order to detect and classify disturbances in power quality. Eight common types of disturbances were analyzed based on the parameters stated in the IEEE 1159 standard. By means of instantaneous frequencies and intrinsic mode functions of each disturbance, the neural network is trained for the classification of these disturbances. The implemented method reached a precision percentage of 94.6, demonstrating the versatility and great potential that this method provides when detecting disturbances in power quality.