Md Akhtar Hossain

Dr. Md Akhtar Hossain

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2016
Verified
Book Chapter
Closed access
PDF file
MHMd Akhtar Hossain
Md Akhtar Hossain
YTY.Z. Totoev
Y.Z. Totoev
MMM.J. Masia
M.J. Masia
This chapter focuses on the experimental investigation of frictional capacities of three different brick surfaces at realistic boundary conditions and loading regime. It explores the experimental findings of the topological Semi Interlocking Masonry (SIM) unit during static and dynamic loading. The chapter describes the experimental results on the friction behavior of mortar-less SIM joints under dynamic and cyclic loading. Mortar-less joints of SIM could be dry or could have some non-adhesive gap filler for improving SIM's water penetration and thermal insulation. In seismic areas SIM can be used in the form of mortar-less engineered panels, which have significant energy dissipation capacity due to the sliding friction between bricks induced during an earthquake. To increase ductility, often masonry is combined with more ductile materials like ductile reinforced concrete frame with masonry panels. According to his system, units in masonry infill panels are capable of relative sliding in-plane of a wall and interlocked to prevent relative sliding out-of-plane of a wall.

1 November 2020 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
MRMahfuzur Rahman
Mahfuzur Rahman
LJLaila Tul Zannat Jyoti
Laila Tul Zannat Jyoti
SPSnahashish Paul
Snahashish Paul
AIAl- Ishmam
Al- Ishmam
MHMd Akhtar Hossain
Md Akhtar Hossain
Super Absorbent Polymer (SAP) is a favorable admixture which can influence various properties of cementitious materials. It mainly improves the water retaining properties of cement-based construction materials. In this paper, an experimental program was carried out to determine the mechanical and thermal performance of cement plaster containing SAP. Firstly, the absorption capacity of SAP was determined in different loading conditions and chloride solutions. Thereafter, the optimum dosage of SAP for cement plaster was also determined from five different proportions of SAP (0.05, 0.1, 0.3, 0.5 and 1% of cement mass) based on the compressive strength test results. The mortar incorporating 0.05% SAP of cement mass was selected as the optimum dosage, which yielded the highest compressive strength. Two slabs of 1í—1í—25 mm with 0.05% SAP and two slabs of 1í—1í—25 mm without SAP were cast to determine the thermal performance of the cement mortar with and without SAP. For this purpose, a wooden chamber of 2í—1í—1 m was constructed and the slab was placed in the middle of this chamber to carry out the thermal performance test of cement mortar. The slabs with 0.05% SAP showed promising results for acting as a thermal barrier in buildings compared to slabs without SAP. Doi: 10.28991/cej-2020-03091614 Full Text: PDF

1 September 2020 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
PDF file
MHMd Akhtar Hossain
Md Akhtar Hossain
YTYuri Z. Totoev
Yuri Z. Totoev
MMMark John Masia
Mark John Masia
An innovative masonry building system, the semi-interlocking masonry (SIM) building system, is being developed in the Centre for Infrastructure Performance and Reliability at The University of Newcastle, Australia. The major motivation in developing the system was to improve the seismic performance of masonry infill panels in framed construction. In seismic areas, SIM can be used as framed mortarless engineered panels, which have significant energy dissipation capacity due to friction on sliding bed joints between units induced during an earthquake. The mortarless joints of SIM can be laid dry or, to improve thermal insulation and water resistance of SIM panels, can have some nonadhesive joint filler. This study focuses on the frictional behavior of three different mortarless SIM bed joint surfaces (dry surface, surface with linseed oil–based putty, and surface with rubber foam tape) for two different types of SIM units (topological and mechanical SIM units). The investigation aims to replicate realistic boundary conditions and loading regime using a modified couplet shear test setup. The constant precompression potentially induced in a masonry infill panel was applied by the static gravity load. Tests were designed to simulate relative sliding of SIM units during earthquakes over the service life of a panel: 160 sliding cycles of ±1.0-mm relative displacement applied dynamically (100  mm/min ). In addition, one cycle of ±10.0-mm displacement was also applied statically (10  mm/min ) for comparison to dynamic frictional behavior. The load-displacement history was recorded. The paper expands significantly from the previously published conference paper and reports the results of this testing program in terms of the friction coefficient (based on Mohr-Coulomb failure criterion) and the energy dissipation characteristics for each type of joint (only for topological SIM unit).


9 April 2025 in Buildings
Verified
Journal Article
Open access
PDF file
CLChee Yin Lam
Chee Yin Lam
MMMark John Masia
Mark John Masia
Igor A ChavesIgor A Chaves
Igor A Chaves
MHMd Akhtar Hossain
Md Akhtar Hossain
JVJohn Vazey
John Vazey
Experimental modal analysis has proven effective in damage identification of civil structures but has not been extensively applied to multi-leaf masonry structures, particularly in the context of wall tie inspection. This paper investigates the applicability of non-destructive, vibration-based damage identification methods to a one-storey masonry veneer wall to detect wall tie deterioration based on changes in modal parameters. An impact hammer was used to collect vibration data from eight different wall tie deterioration test cases by disconnecting the wall ties at various locations. The downshift of natural frequencies was recorded for all deterioration test cases, and a reduction of up to 38% was observed when the top row of wall ties was disconnected, highlighting the importance of wall ties to the overall stiffness of the masonry veneer wall system. In terms of damage localisation accuracy, the parameter-based method performed the best by successfully identifying seven out of eight damaged scenarios without additional noise. The findings show that the detection of wall tie deterioration using non-destructive, vibration-based damage identification methods is viable, providing an alternative wall tie inspection method with significant benefits to infrastructure management, thereby enhancing safety, efficiency, and sustainability in maintaining and preserving masonry veneer walls.

1 March 2025 in Journal of Structural Engineering
Verified
Journal Article
Closed access
LGLewis J. Gooch
Lewis J. Gooch
MMMark John Masia
Mark John Masia
MSMark G. Stewart
Mark G. Stewart
MHMd Akhtar Hossain
Md Akhtar Hossain