Historically, in the city of Tunja there has been a phenomenon of occupation of the natural channels of rainwater, altering the hydrology of the natural basins. Currently, the city is experiencing considerable and accelerated urban development towards the Northeast, which has resulted in overflows in the drainage system and floods that have affected residents. The current drainage system is not capable of registering the flow of water that leaves the urban sector due to a lack of instrumentation. In this study, precipitation and water flow equipment was installed in the northeastern district of the city, also known as Barrio Santa Ines. The basin was separated into 56 different sub-basins with physical and drainage parameters calculated for each sub-basin. The associated parameters were calibrated to the initial hydrological losses and roughness. A validated and calibrated urban drainage model was created in the program SWMM 5.1, allowing for the temporal hydrodynamic modelling of the system to be obtained. The model reproduces the real evolution of the system and was used in order to make predictions according to a maximum precipitation design event. This model resulted in the detection of two areas that are vulnerable to flooding. The identification of different sub-basins and the desegregation of the hydrodynamic model resulted in a reduction in the uncertainty of the evolution of water flow in the system.
12 December 2022 in Environmental Research, Engineering and Management
Floods are one of the causes of ground movement and displacement, and due to rapid urbanization and urban growth may occur more frequently than before. The characteristics of an urban drainage system can define the occurrence and extent of flooding, where catchment elements have a determining role. This document presents the numerical investigation of the hydraulic inlet efficiency and the discharge coefficient of seven types of grate inlets. The FLOW-3D® simulator is used to test the gratings at a full scale, under flow rates of Q = 24, 34.1, 44, 100, 200 and 300 L/s, preserving the configuration of the experimental prototype with longitudinal slopes of 1.0%, 1.5% and 2.0% and a fixed cross slope, for a total of 126 models. Based on the results, hydraulic inlet efficiency curves and discharge coefficients are constructed for each type and a longitudinal slope condition. The results are adjusted with empirical formulations proposed in other investigations, serving to verify the results of physical testing of prototypes.
Objective: This research aimed to design a drainage quality hydrodynamic model of the northeastern sector of Tunja (Santa Inés neighborhood), Boyacá, Colombia, which was validated and calibrated by means of the mean square error method, where a comparison between the values observed in the field and the simulation results in the model was determined in order to observe and analyze the effect of precipitation on pollutants before entering the treatment plant. Methodology: For this study, rainfall and water flow equipment were installed in the district. A validated and calibrated urban drainage model was created on the SWMM 5.1 software, which allowed a temporal hydrodynamic modeling of the system. In addition, samples were taken to determine the quality of the water arriving at the treatment plant and evaluate the transportation of pollutants, as well as the possibility of hydrogen sulfide generation in the study area. Results: The results obtained with the model show that all pollutants generate drag in their concentrations. An excess of these values is observed within the total flow, which demonstrates the relevance of accumulation, washing, and transport processes, in light of the pollutant remnants causing the flow to decrease before the pollutant load. Conclusions: Our sampling indicates that it is necessary to analyze the coliforms present in wastewater discharges, as well as the sulfate, nitrite, and nitrate values in the case of a specific discharge. The entity in charge of discharge control must be then informed.
In rivers, longitudinal walls are protective structures that are directly supported on the riverbank are frequently used as hydraulic prevent the current from eroding the bank and causing scouring. However, these structures have the potential to block flow and produce erosive processes that progressively worsen scour in their area, leading to faulting and other problems. The current study used Flow-3D software to understand the scour process at the base of longitudinal walls in rivers with a well-graded granular bed. Experimental data from a physical model replicating a river with a longitudinal wall and a well-graded granular bed were used to validate the model. The investigation examined the average flow velocity and its effects on scour behavior along the longitudinal wall using the Flow-3D program. The findings showed that the Flow-3D model could improve the evaluation of debugging processes, because it provided a useful answer that closely matched the experimental data derived from the physical model. Validation with a 0.07 m mesh demonstrated that the Flow-3D model could faithfully simulate the scour process along the longitudinal wall. Overall, the findings of this study suggest that the Flow-3D software can be a useful tool for predicting the scouring process in rivers with well-graded granular beds and longitudinal walls. This is particularly important for engineers and researchers who are interested in designing and optimizing hydraulic structures to mitigate the effects of scouring, because it provided a useful answer that closely matched the experimental data derived from the physical model
1 November 2019 in Journal of Physics: Conference Series
Depositing the solid waste generated by wastewater treatment in landfills presents an environmental problem due to the leaching of nitrogen and subsequent eutrophication and contamination of aquafers. Glass is a material with a wide array of uses which is often disposed of after completing its use. This study evaluates an alternative to the production of bricks by replacing clay for recycled glass and sludge ash in proportions of 10% and 20%. The physical properties of the fabricated bricks (compressive strength, water absorption, and the initial rate of absorption) were then measured. The temperature used in the firing process was 950 °C. The fabricated bricks utilizing the proposed mixtures complied with the Colombian technical code for structural and non-structural brick exceeding 20 MPa. This alternative method of brick fabrication reduces the environmental impact of glass and solid waste on the ecosystem and reduce freshwater contamination. It will also solve the issue of the sludge waste produced by wastewater treatment plants.
The present study evaluates the electrochemical behaviour of reinforcing steel embedded in an alkali-activated eco-cellular geopolymer concrete designed for applications in environments with high chloride exposure. The material was formulated using a ternary precursor composed of fluid catalytic cracking residue (FCC), Class F fly ash, and ground granulated blast furnace slag (BFS), activated with an alkaline solution and combined with preformed foam to generate a microstructure characterised by predominantly closed porosity and low capillary connectivity. The electrochemical response of the system was assessed through open circuit potential (OCP) measurements, Tafel polarisation curves, electrochemical impedance spectroscopy (EIS), and potentiodynamic tests under accelerated exposure to NaCl solutions. The results demonstrate a markedly improved electrochemical performance, evidenced by shifts in OCP towards more noble values, reductions of 45–65% in corrosion current density (Icorr), and increases of up to fourfold in charge transfer resistance (Rct), together with the development of broader and more stable passive regions. This behaviour is attributed to the synergistic interaction between the formation of dense N-(C)-A-S-H (sodium/calcium–aluminosilicate hydrate) and C-(A)-S-H (calcium–aluminosilicate hydrate) gels, the eco-cellular architecture with low capillary connectivity, and the stable high alkalinity of the activated matrix, which collectively restrict ionic transport and promote the passive stability of the reinforcing steel—defined here by noble OCP values, low Icorr, high Rct, and sustained passive domains in polarisation curves. Overall, the findings position the developed eco-cellular geopolymer concrete as a sustainable, high-performance alternative for infrastructure exposed to chloride-rich environments.