Miguel Martinez-Mondragon

Dr. Miguel Martinez-Mondragon

Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos, Zacatenco, Mexico City, Ciudad de México, Mexico
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2024 in Materials
Verified
Journal Article
Open access
PDF file
Miguel Martinez-MondragonMiguel Martinez-Mondragon
Miguel Martinez-Mondragon
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
MGMiguel Angel García
Miguel Angel García
ACAldo Saul Laguna Canales
Aldo Saul Laguna Canales
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
The use of titanium as a biomaterial for the treatment of dental implants has been successful and has become the most viable and common option. However, in the last three decades, new alternatives have emerged, such as polymers that could replace metallic materials. The aim of this research work is to demonstrate the structural effects caused by the fatigue phenomenon and the comparison with polymeric materials that may be biomechanically viable by reducing the stress shielding effect at the bone–implant interface. A numerical simulation was performed using the finite element method. Variables such as Young’s modulus, Poisson’s coefficient, density, yield strength, ultimate strength, and the S-N curve were included. Prior to the simulation, a representative digital model of both a dental implant and the bone was developed. A maximum load of 550 N was applied, and the analysis was considered linear, homogeneous, and isotropic. The results obtained allowed us to observe the mechanical behavior of the dental implant by means of displacements and von Mises forces. They also show the critical areas where the implant tends to fail due to fatigue. Finally, this type of non-destructive analysis proves to be versatile, avoids experimentation on people and/or animals, and reduces costs, and the iteration is unlimited in evaluating various structural parameters (geometry, materials, properties, etc.).

2 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DADaniel Maya Anaya
Daniel Maya Anaya
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
Miguel Martinez-MondragonMiguel Martinez-Mondragon
Miguel Martinez-Mondragon
JGJESUS MANUEL GERMAN-CARCAÑO
JESUS MANUEL GERMAN-CARCAÑO
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
Numerical analysis computational programs are applied to the research of biological tissues, which have complex forms. Continuous technological advance has facilitated the development of biomodels to evaluate biological tissues of different human body systems using computerized axial tomography to produce complex three-dimensional models that represent the morphological and physiological characteristics of the real tissues. Biomodels are applied to numerical analysis using the Finite Element Method and provide a perspective of the mechanical behavior in the system. In this study, a numerical evaluation was performed by developing a biomodel of the humerus, radius, and ulna (the elbow joint, composed of cortical bone, trabecular bone, and cartilage). Also introduced to the biomodel were the ligaments of the capsule joint, collateral ligaments of the ulna, and collateral ligaments of the radius. The biomodel was imported into a computer program to perform a numerical analysis considering the mechanical properties of cortical and trabecular bone (including elasticity modulus, shear modulus, Poisson relation, and density). The embedding conditions were defined to restrict displacements and rotations in the proximal zone of the humerus, applying a compression load to the other end of the biomodel at the distal area of the radius and ulna. The results are the direct consequence of how boundary conditions and external agents are applied to the structure to be analyzed, and the data obtained show how the behavior of the force applied through the component produces stresses and strains as a whole, as well as for each of the components. These stresses and strains can indicate zones with structural problems and the detection areas causing pain (assisting in a better diagnosis).

7 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
Miguel Martinez-MondragonMiguel Martinez-Mondragon
Miguel Martinez-Mondragon
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
DADaniel Maya Anaya
Daniel Maya Anaya
Jacobo Martínez-ReyesJacobo Martínez-Reyes
Jacobo Martínez-Reyes
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
Dental implants have become an alternative to replace the teeth of people suffering from edentulous and meet the physiological and morphological characteristics (recovering 95% of the chewing function). The evolution and innovation of biomaterials for dental implants have had a trajectory that dates back to prehistory, where dental pieces were replaced by ivory or seashells, to the present day, where they are replaced by metallic materials such as titanium or ceramics such as zirconium or fiberglass. The numerical evaluation focuses on comparing the stress distribution and general displacement between different dental implants and a healthy tooth when applying a force of 850 N. For the analysis, a model of the anatomical structure was developed of a healthy tooth considering three essential parts of the tooth (enamel, dentin, and pulp). The tooth biomodel was established through computed tomography. Three dental implant models were considered by changing the geometry of the abutment. A structural simulation was carried out by applying the finite element method (FEM). In addition, the material considered for the analyses was zirconium oxide (ZrO2), which was compared against titanium alloy (Ti6Al4V). The analyses were considered with linear, isotropic, and homogeneous properties. The variables included in the biomodeling were the modulus of elasticity, Poisson’s ratio, density, and elastic limit. The results obtained from the study indicated a significant difference in the biomechanical behavior of the von Mises forces and the displacement between the healthy tooth and the titanium and zirconium implant models. However, the difference between the titanium implant and the zirconium implant is minimal because one is more rigid, and the other is more tenacious.

18 July 2023 in Fluids
Verified
Journal Article
Open access
PDF file
ACAldo Saul Laguna Canales
Aldo Saul Laguna Canales
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
Miguel Martinez-MondragonMiguel Martinez-Mondragon
Miguel Martinez-Mondragon
MGMiguel Angel García
Miguel Angel García
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
In motorsports, the correct design of every device that constitutes a vehicle is a significant task for engineers because the car’s efficiency on the track depends on making it competitive. However, the physical integrity of the pilot is also at stake, since a bad vehicle design can cause serious mishaps. To achieve the correct development of a front wing for a single-seater vehicle, it is necessary to adequately simulate the forces that are generated on a car to evaluate its performance, which depends on the aerodynamic forces of the front wing that are present due to its geometry. This work provided a new design and evaluation through the numerical analysis of three new front wings for single-seater vehicles that comply with the regulations issued by the International Automobile Federation (FIA) for the 2022 season. Additionally, a 3D-printed front wing prototype was developed to be evaluated in an experimental study to corroborate the results obtained through computer simulations. A wind tunnel experiment test was performed to validate the numerically simulated data. Also, we developed a numerical simulation and characterization of three front wings already used in Formula One from a previous season (the end of the 2021 season). This work defined how these devices perform, and in the same way, it identified how their evolution over time has provided them with substantial benefits and greater efficiency. All the numerical simulations were carried out by applying the Finite Volume Method, allowing us to obtain the values of the aerodynamic forces that act on the front wing. Also, it was possible to establish a comparison between the three newly designed proposals from the most aerodynamic advantages to produce a prototype and perform an experimental test. The results of the experimental test showed similarity to those of the numerical analyses, making it clear that the methodology followed during the development of the work was correct. In addition, the mechanical designs carried out to develop the front wing can be considered ideal, because the results showed that the front wing could be competitive, and applying it caused a downforce to be favored that prevented the car from being thrown off the track. Additionally, the results indicate this is an effective proposal for use in a single-seater vehicle and that the design methodology delivers optimal results.

3 October 2024 in Fluids
Verified
Journal Article
Open access
PDF file
ACAldo Saul Laguna Canales
Aldo Saul Laguna Canales
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
Miguel Martinez-MondragonMiguel Martinez-Mondragon
Miguel Martinez-Mondragon
MGMiguel Angel García
Miguel Angel García
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
The last change in the technical regulations of Formula One that came into force in 2022 brought with it significant changes in the aerodynamics of the vehicle; among these, those made to the front wing stand out since the wing was changed to a more straightforward shape with fewer parts but with no less efficiency. The reduction in its components suggests that if one part were to suffer damage or break down, the efficiency of the entire front wing would be affected; however, from 2022 to date, there have been occasions in which the cars have continued running on the track despite losing some of the endplates. This research seeks to understand the endplates’ impact on the front wing through a series of CFD simulations using the k-ω SST turbulence model. To determine efficiency, the aerodynamic forces generated on the vehicle’s front wing, suspension, and front wheels were compared in two different operating situations using a model with the front wing in good condition and another in which the endplates were removed. The first case study simulated a straight line at a maximum speed where the Downforce is reduced by 2.716% while the Drag and Yaw increase by 7.092% and 96.332%, respectively, when the model does not have endplates. On the other hand, the second case study was the passage through a curve with a decrease of 17.707% in Downforce, 6.532% in Drag, and 22.200% in Yaw.