The line impedance stabilization network (LISN) is mostly used in electromagnetic compatibility (EMC) for conducted and radiated radio frequency emission and susceptibility tests. The input impedance is one of the most important parameters in LISN calibration. To measure the input impedance, an adapter is required to connect the vector network analyzer to the equipment under test port of the LISN. For EMC test laboratories, it is of best interest to perform this calibration with high accuracy. Until now, the impact of the adapter used has not been clearly demonstrated theoretically. This paper explains the magnitude and phase impedance errors caused by the adapter. Theoretical and practical methods for the elimination of generated error are given. We present the design of two sets of adapters and their associated modeling, a method for removing their impact from the measurement, the theoretical error on magnitude and phase input impedance, and the uncertainties related to the impedance measurement.
31 July 2018 in IEEE Transactions on Instrumentation and Measurement
Usually high wideband ac current and harmonics measurements are accurately achieved in industry and laboratories by using high accuracy shunts or standard shunts. For particular applications, such as power and transient measurements, it is mandatory to evaluate the shunt impedance phase and magnitude according to the frequency bandwidth of interest before to measure the current with such sensors. High electrical current shunt beyond 1 A is calibrated in magnitude up to 100 kHz and in phase angle up to 200 kHz only by a few National Metrology Institutes. The existing traceable measurement methods to characterize these sensors are limited in frequency to 100 kHz, with expanded uncertainties of the ac-dc difference (magnitude) and the phase angle of more than 5 × 10 -6 and 62 μrad at 100 kHz, respectively. A new traceable calibration method to measure and characterize current shunts at high frequencies is presented in this paper. This measurement method is based on the use of a vector network analyzer. The measurements are presented up to 60 MHz, but theoretically, the presented method does not exhibit a specific frequency limitation. Only the characteristics of the shunt under study can impose limitation in practice. While uncertainties are higher than those provided by the existing methods, the method presented in this paper is the only method able to perform in one step a broadband and simultaneous measurement of the magnitude and phase of current shunts up to few megahertz with acceptable uncertainties.
Electrical current shunts used as resistance standards in metrology laboratories are characterized by a broadband operating frequency bandwidth and are commonly calibrated up to 100 kHz. The use of a current shunt requires the preliminary knowledge of its magnitude deviation from DC and phase angle according to the frequency. The best magnitude performances published so far are limited to \pmb2 μΩ/Ω at 100 kHz. In this paper, we present an innovative shunt design for current measurements at 10 A up to 1 MHz. The relative deviation from DC is less than \pmb0.2 μΩ/Ω and \pmb20 μΩ/Ω in magnitude at 100 kHz and 1 MHz respectively.
24 December 2018 in IEEE Transactions on Instrumentation and Measurement
Electrical current shunts are widely used as a resistance standard in metrology laboratories and precision instruments with the aim of measuring a high level of alternative and direct currents (ac and dc) with high accuracy. These ac current sensors are characterized by a broadband operating frequency bandwidth and are commonly calibrated up to 100 kHz. The use of a current shunt requires the preliminary knowledge of its magnitude deviation from dc and phase angle according to the frequency. The determination of these parameters is challenging at high frequencies and for high levels of current: typically beyond 100 kHz and 1 zA. For a current level of 10 A, existing current shunts exhibit a strong variation in magnitude and phase. The best magnitude performances of 10-A current shunt standards published so far are limited to 2 μ Ω /Ω at 100 kHz. In this paper, we detail the theoretical basis of innovate shunts for current measurements from 50 mA to 10 A up to 1 MHz. The electrical modeling is valid from 50 mA to 10 A: only the Rdc value must be changed to get the electromagnetic response of any shunt standards designed for this range of current levels. For a 10-A shunt standard, the relative deviation from dc obtained by calculation is less than 0.2 and 20 μ Ω /Ω in magnitude at 100 kHz and 1 MHz, respectively. The design as well as the electromagnetic modeling of the shunt is profoundly described in this paper.
This paper presents the evolution of LNE’s impedance bridge (Wheatstone bridge) used to calibrate AC resistors defined in the two terminal-pair configuration. A new automated Wheatstone bridge, based on four resistances, was developed to operate in the full complex plane for resistances ranging from 400 Ω to 2 MΩ and for frequencies up to 20 kHz. A commercial dual precision arbitrary waveform generator supplies the bridge and PXI modules achieve the balance. Phase and frequency synchronization solutions between the arbitrary waveform generator source and the PXI modules were used. The choice of these instruments allows the bridge to be easily automated and to benefit from recent progress in the development of digital-analog converters, in particular those with high frequency sampling rates and resolution. The bridge is mainly dedicated to realize the periodic calibration of LNE’s standard resistors, used for routine customer calibrations. The traceability of LNE’s standard resistors is ensured, firstly, by the calibration of a 1 kΩ resistor by comparison to a calculable resistor up to 20 kHz. Then, this resistor is used as a reference element to ensure the traceability of all LNE’s standard resistors using the new bridge. The validation was done by comparing the results obtained, for some resistors with very low drift, with those obtained during calibrations performed in 1983, 1995 and 2009. For resistors of 1 kΩ in a 1:1 ratio, the expanded uncertainty of series resistance variation and argument are, respectively, less than 1.3 µΩ Ω−1 (k = 1) and 1.2 µrad (k = 1), up to 20 kHz.
For this study, a substitution principle-based impedance bridge has been developed to calibrate AC resistors in a four-terminal-pair (4TP) configuration. The calibration is performed in the full complex plane for resistances ranging from 100 mΩ to 400 Ω and frequencies of between 50 Hz and 20 kHz. The automated bridge is based on four resistors associated with two high-impedance stages. The balancing of the bridge is achieved by means of PXI modules. The bridge is automatically balanced via a simplex top-down algorithm. The new bridge is primarily used for the measurement chain of AC standard resistors defined in a 4TP configuration at LNE, which are used for routine customer calibrations. The traceability of LNE’s standard resistors when defined in a 4TP configuration is ensured by a measurement chain from a 1 kΩ reference resistor using the new bridge. The reference resistor was calibrated previously via comparison with a calculable resistor up to 20 kHz. The bridge was validated via comparison with calibration results obtained in 1983 and 2009. For a resistor of 1 Ω at 1 kHz, the uncertainty of the series resistance variation and the phase shift are less than 6 µΩ/Ω (k = 1) and 6 µrad (k = 1), respectively.