Recently, the number of electric vehicles (EVs) is increasing due to the decline of oil resources and the rising of greenhouse gas emissions. However, EVs have not received full acceptance by consumers due to the limitations of the stored energy and charging problems. The dynamic or in-motion charging solution has become a suitable choice to solve the battery-related issues. Many researchers and vehicle manufacturers are working to develop an efficient charging system for EVs. In order to improve the efficiency of the dynamic wireless power transfer (DWPT), the electromagnetic coupling coefficient between the two parts of the coupler must be maximized. This paper was dedicated to find the optimal topology of a magnetic coupler with the best coupling factor while taking in consideration the displacement and the misalignment of the EV. The article is introduced by developing a methodology for characterizing the electrical parameters of couplers, followed by a comparative study of different forms of coils suitable for dynamic charging of electric vehicles. The particularity of the proposed study concerned the overall dimensions, or the areas occupied by the windings of the coils remaining the same for all the chosen shapes and corresponding to the surface that is actually available under the EV. Simulation and experimental tests were carried out to validate the proposed study.
The current charging technology for electric vehicles consists of plugging the cable from the AC utility to charge the batteries. This requires heavy gauge cables to connect to electric vehicles, which can be difficult to handle, presents tripping hazards, and is prone to vandalism. In addition to these inconveniences, electric vehicles must be immobilized for hours before being fully charged. Dynamic wireless power transfer has been studied worldwide as a promising technology. It is safe and convenient and allows electric vehicles to charge while moving. To improve the efficiency of a dynamic wireless power transfer system, the magnetic coupling coefficient must be maximized between the primary pad, which is integrated into the road, and the secondary pad installed in the electric vehicle. This article presents a parametric optimization of the ferrite structure used for a 3 kW dynamic wireless power transfer prototype. Different ferrite configurations are compared while studying the effect of the parameter values on their magnetic coupling coefficient. Finally, the proposed structure was validated during the experimental test, and its coupling coefficient was improved by 26% compared to the original structure.
26 October 2017 in IEEE Antennas and Wireless Propagation Letters
This paper focuses on the HF (High Frequency) wireless power transfer (WPT) by electromagnetic induction and its dependence on the lateral misalignment and tilt of the small receiving coil relative to the transmitting coil. We combine two structures, the TLA (Twisted Loop Antenna) and sub-coils of a DDC (Distributed Diameter Coil) for transmitting designs. Our system is then referred as TLA-DDC. The radius of the sub-coils is parametrically varied for different distances between the coils and performed in two positions for each distance (coaxial position when the receiving coil is parallel to the plane of the transmitting coil, and center position for the perpendicular orientation of both coils). Then, using different radii for the transmitting DDC TLA when the receiving coil is moved onto its surface allows obtaining a greater value of efficiency at different positions: up to 2.4 times for the peak value and 1.5 for the average value for receiving coil in parallel plane. The efficiency of the magnetic coupling is determined by means of power efficiency with a comparison between the DDC TLA antennae and a standard coil antenna corresponding to the same inductance value.
Electrical current shunts are widely used as a resistance standard in metrology laboratories and precision instruments with the aim of measuring a high level of alternative and direct currents (ac and dc) with high accuracy. These ac current sensors are characterized by a broadband operating frequency bandwidth and are commonly calibrated up to 100 kHz. The use of a current shunt requires the preliminary knowledge of its magnitude deviation from dc and phase angle according to the frequency. The determination of these parameters is challenging at high frequencies and for high levels of current: typically beyond 100 kHz and 1 zA. For a current level of 10 A, existing current shunts exhibit a strong variation in magnitude and phase. The best magnitude performances of 10-A current shunt standards published so far are limited to 2 μ Ω /Ω at 100 kHz. In this paper, we detail the theoretical basis of innovate shunts for current measurements from 50 mA to 10 A up to 1 MHz. The electrical modeling is valid from 50 mA to 10 A: only the Rdc value must be changed to get the electromagnetic response of any shunt standards designed for this range of current levels. For a 10-A shunt standard, the relative deviation from dc obtained by calculation is less than 0.2 and 20 μ Ω /Ω in magnitude at 100 kHz and 1 MHz, respectively. The design as well as the electromagnetic modeling of the shunt is profoundly described in this paper.
1 January 2018 in Progress in Electromagnetics Research C