Instrument transformers (ITs) play a key role in electrical power systems, facilitating the accurate monitoring and measurement of electrical quantities. They are essential for measurement, protection, and metering in transmission and distribution grids and accurately reducing the grid voltage and current for low-voltage input instrumentation. With the increase in renewable energy sources, electronic converters, and electric vehicles connected to power grids, ITs now face challenging distorted conditions that differ from the nominal ones. The study presented in this paper is a collaborative work between national metrology institutes and universities that analyzes IT performance in measuring distorted voltages and currents in medium-voltage grids under realistic conditions. Both current and voltage measuring transformers are examined, considering influence quantities like the temperature, mechanical vibration, burden, adjacent phases, and proximity effects. The study provides detailed insights into measurement setups and procedures, and it quantifies potential errors arising from IT behavior in measuring distorted signals in the presence of the various considered influence quantities and their combinations. The main findings reveal that the temperature has the most evident impact on the inductive voltage transformer performance, as well as the burden, causing significant changes in ratio error and phase displacement at the lower temperatures. As for low-power ITs, establishing a priori the effects of adjacent phases and proximity on the frequency responses of low-power ITs is a complex matter, because of their different characteristics and construction solutions.
Instrument transformers are largely used to measure voltages and currents in public electricity networks. Their performance is essential for Power Quality measurements. Tests and procedures to estimate the effect of single influence factors are performed according to current standards. However, the instrument transformers are exposed simultaneously to more than one factor. The standardized procedures for their characterization with combined influence factors are under construction in Europe. The work in this paper is focused on the development of a new set-up for the determination of the accuracy and frequency response of medium-voltage transformers within the combined influence factors of temperatures and vibrations. The test set-up includes a platform for the combination of temperature and vibrations, a generating system for harmonics up to 9 kHz superposed with 35 kV, 50 Hz voltage and a reference measuring system. The results of several tests carried out on a 35 kV/100 V/50 Hz voltage transformer in the presence of these influence factors are discussed in this paper. They show that the accuracy and frequency response of the voltage transformers are more influenced by temperature than by vibrations.
The phenomenon of high-frequency distortion (HFD) in the electric grids, at both low-voltage (LV) and medium-voltage (MV) levels, is gaining increasing interest within the scientific and technical community due to its growing occurrence and the associated impact. These disturbances are mainly injected into the grid by new installed devices, essential for achieving decentralized generation based on renewable sources. In fact, these generation systems are connected to the grid through power converters, whose switching frequencies are significantly increasing, leading to a corresponding rise in the frequency of the injected disturbances. HFD represents a quite recent issue, but numerous scientific papers have been published in recent years on this topic. Furthermore, various international standards have also covered it, to provide guidance on instrumentation and related algorithms and indices for the measurement of these phenomena. When measuring HFD in MV grids, it is necessary to use instrument transformers (ITs) to scale voltages and currents to levels fitting with the input stages of power quality (PQ) instruments. In this respect, the recently released Edition 2 of the IEC 61869-1 standard extends the concept of the IT accuracy class up to 500 kHz; however, the IEC 61869 standard family provides guidelines on how to test ITs only at power frequency. This paper provides an extensive review of literature, standards, and the main outputs of European research projects focusing on HFD and ITs. This preliminary study of the state-of-the-art represents an essential starting point for defining significant waveforms to test ITs and, more generally, to achieve a comprehensive understanding of HFD. In this framework, this paper provides a summary of the most common ranges of amplitude and frequency variations of actual HFD found in real grids, the currently adopted measurement methods, and the normative open challenges to be addressed.
This paper presents the development and characterization of a reference high-voltage sensing chain for the calibration and conformity assessment of instrument transformers with Class 0.1-WB3, in the extended frequency range up to 150 kHz, according to IEC 61869. The sensing chain, composed of a high-voltage divider, precision attenuators and high-pass filters, has been specifically developed and characterized. The chain features two parallel measurement paths: the first path, comprising the high-voltage divider and attenuator, is optimized for measuring the fundamental frequency superimposed with high-amplitude harmonics; the second path, consisting of the high-voltage divider followed by a high-pass filter, is dedicated to measuring very-low-level superimposed harmonic components by enhancing the signal-to-noise ratio. These two paths are integrated with a digitizer to form a complete and modular measurement chain. The expanded uncertainty of measurement has been thoroughly evaluated and confirms the chain’s ability to support assessment of instrument transformers with Class 0.1-WB3 compliance. Additionally, the chain architecture enables a future extension up to 500 kHz, addressing the growing need to evaluate instrument transformers under high-frequency power quality disturbances and improving the sensing capability in this field.
This paper presents the evolution of LNE’s impedance bridge (Wheatstone bridge) used to calibrate AC resistors defined in the two terminal-pair configuration. A new automated Wheatstone bridge, based on four resistances, was developed to operate in the full complex plane for resistances ranging from 400 Ω to 2 MΩ and for frequencies up to 20 kHz. A commercial dual precision arbitrary waveform generator supplies the bridge and PXI modules achieve the balance. Phase and frequency synchronization solutions between the arbitrary waveform generator source and the PXI modules were used. The choice of these instruments allows the bridge to be easily automated and to benefit from recent progress in the development of digital-analog converters, in particular those with high frequency sampling rates and resolution. The bridge is mainly dedicated to realize the periodic calibration of LNE’s standard resistors, used for routine customer calibrations. The traceability of LNE’s standard resistors is ensured, firstly, by the calibration of a 1 kΩ resistor by comparison to a calculable resistor up to 20 kHz. Then, this resistor is used as a reference element to ensure the traceability of all LNE’s standard resistors using the new bridge. The validation was done by comparing the results obtained, for some resistors with very low drift, with those obtained during calibrations performed in 1983, 1995 and 2009. For resistors of 1 kΩ in a 1:1 ratio, the expanded uncertainty of series resistance variation and argument are, respectively, less than 1.3 µΩ Ω−1 (k = 1) and 1.2 µrad (k = 1), up to 20 kHz.
For this study, a substitution principle-based impedance bridge has been developed to calibrate AC resistors in a four-terminal-pair (4TP) configuration. The calibration is performed in the full complex plane for resistances ranging from 100 mΩ to 400 Ω and frequencies of between 50 Hz and 20 kHz. The automated bridge is based on four resistors associated with two high-impedance stages. The balancing of the bridge is achieved by means of PXI modules. The bridge is automatically balanced via a simplex top-down algorithm. The new bridge is primarily used for the measurement chain of AC standard resistors defined in a 4TP configuration at LNE, which are used for routine customer calibrations. The traceability of LNE’s standard resistors when defined in a 4TP configuration is ensured by a measurement chain from a 1 kΩ reference resistor using the new bridge. The reference resistor was calibrated previously via comparison with a calculable resistor up to 20 kHz. The bridge was validated via comparison with calibration results obtained in 1983 and 2009. For a resistor of 1 Ω at 1 kHz, the uncertainty of the series resistance variation and the phase shift are less than 6 µΩ/Ω (k = 1) and 6 µrad (k = 1), respectively.