This paper presents a hybrid control strategy which combines the nearest level control technique with PWM control technique on a cascaded H-Bridge Multilevel Inverters (MLI). MLIs have become very popular due to its several advantages in the application areas like industrial drives and grid-connected renewable energy generation systems. With the reduced number of switches, driver circuits, conduction losses, switching losses, voltage stresses, size, and cost of the system, MLI has outperformed its two-level counterpart in terms of power quality issues. Reduction in the Harmonics and consequently the Total Harmonic Distortion (THD) in the output voltage has added to the benefits of MLI. Topological advancements in MLI require a satisfactory output voltage control strategy. In this work, a hybrid control strategy for a smooth and wider range of control of output voltage is proposed. The hybridized scheme enhances the control range of the voltage considerably. Moreover, the THD is also reduced compared to the conventional sinusoidal PWM scheme. A thorough analysis of the scheme has also been presented in the paper. SIMULINK/ MATLAB environment is used for testing the simulation model of the proposed control scheme. This hybridized controlling technique is also simulated for thermal modelling on PLECS software and power loss analysis is performed. The mathematical and simulation analyses are validated on an experimental prototype using a TMS320F28335 DSP controller card. The hybrid scheme has also been tested for a fault tolerant model of the cascaded H-bridge inverter. The performance of the hybrid scheme under different fault condition has also been shown to work satisfactorily.
This paper presents the Archimedes optimization algorithm to eliminate selective harmonics in a cascaded H-bridge (CHB) multilevel inverter (MLI). The foremost objective of the selective harmonic elimination (SHE) is to eliminate lower order harmonics by finding the optimal switching angle combination which minimizes the objective function containing Total Harmonic Distortion (THD) and other specific harmonic terms. Consequently, the THD is also reduced. In this study, a recently proposed metaheuristic technique named the Archimedes optimization algorithm (AOA) is used to determine the optimal angles corresponding to the 5, 7 and 9 level CHB-MLI. AOA involves equations related to a physical law, the Archimedes Principle. It is based on the idea of a buoyant force acting upward on a body or object that is partially or completely submerged in a fluid, and the upward force is related to the weight of the fluid displaced. This optimization technique has been implemented on CHB-MLI to generate various level outputs, simulated on MATLAB™ R2021a version environment software. The simulation results reveal that AOA is a high-performance optimization technique in terms of convergence speed and exploitation-exploration balance and is well-suited to the solution of the SHE problem. Furthermore, the laboratory validated the simulation result on a hardware setup using DSP-TMS320F28379D.
Multilevel inverters (MLIs) are capable of producing high-quality output voltage and handling large amounts of power. This reduces the size of the filter while also simplifying the circuitry. As a result, they have a wide range of applications in industries, particularly in smart grids. The input voltage boosting feature is required to use the MLI with renewable energy. Moreover, many components are required to get higher output voltage levels that add weight and cost to the circuit. Numerous MLI topologies have been identified to minimize the losses, device count, and device ratings. A seven-level modified H-bridge inverter with a reduced component count, and reduced THD is presented in this paper. Two DC sources with six IGBTs have been used to generate a seven-level output voltage, and the Aquila Optimizer (AO) has been implemented to get the regulated output. MATLAB/Simulink environment has been used for designing the simulation model. Furthermore, the simulation result has been validated in the laboratory on a hardware setup using the DSP-TMS320F28335 Launchpad. With the reduced number of switching devices as well as the dc supply, the size of the inverter is compacted and becomes more economical.
In order to commercialize & utilize the PV energy properly, connect it to the grid is a more viable option. Therefore, the study of grid-connected solar PV generation system has gained wide attention. Optimizing output power from a solar photovoltaic module and simultaneous reduction in the harmonics in the line current is of special attention because the efficiency of the solar PV cell is quite low. The conventional line-commutated inverter (commonly used in grid-connected inverter) introduces line current of square-shaped which contains the higher-order harmonics and causes heating of the core of the transformer. The thyristors/SCR based switches have low switching losses and their power handling capability and reliability increases in comparison to the MOSFET/IGBT switches. Nevertheless, for PWM applications, the traditional thyristor-based forced commutated inverters are not appropriate due to the issue of commutation circuits. In this work, a three-phase cascaded full bridge inverter (Rectifier operating in inversion mode) topology has been utilized to produce the seven levels in the input grid current, which is closer to a sinusoidal wave and hence has lower total harmonic distortion (THD). The modular nature of cascaded bridge type configuration is suitable for grid connected solar PV inverter. The results of the proposed scheme have been verified successfully in the MATLAB Simulink environment. The performance of the cascaded configuration is tested for THD in line current, power factor and power transfer capability (PV to the grid). The enhanced performance is obtained by applying a metaheuristic algorithm and meticulous selection of performance parameter.