A wide variety of 3D printing technologies have been used for the fabrication of lab-on-a-chip (LOC) devices in recent years. Despite the large number of studies having examined the use of 3D printing technologies in microfluidic devices, the effect of the fabrication method on their performance has received little attention. In this paper, a comparison is shown between unibody-LOC micro-mixers, a particular type of monolithic design for 3D printed LOCs, fabricated in polyjet, stereolithography (SLA) and fused deposition modelling (FDM or FFF) platforms, paying particular attention to the inherent limitations of each fabrication platform and how these affect the performance of the manufactured devices.
The human body is one of the most complicated objects to model because of its complex features, non-rigidity, and the time required to take body measurements. Basic technologies available in this field range from small and low-cost scanners that must be moved around the body to large and high-cost scanners that can capture all sides of the body simultaneously. This paper presents an image-based scanning system which employs the structure-from-motion method. The design and development process of the scanner includes its physical structure, electronic components, and the algorithms used for extracting 3D data. In addition to the accuracy, which is one of the main parameters to consider when choosing a 3D scanner, the time and cost of the system are among the most important parameters for evaluating a scanner system in the field of human scanning. Because of the non-static nature of the human body, the scanning time is particularly important. On the other hand, a high-cost system may lead to limited use of such systems. The design developed in this paper, which utilizes 100 cameras, facilitates the acquisition of geometric data in a fraction of a second (0.001 s) and provides the capabilities of large, freestanding scanners at a price akin to that of smaller, mobile ones.
The need for accessible and inexpensive microfluidic devices requires new manufacturing methods and materials as a replacement for traditional soft lithography and polydimethylsiloxane (PDMS). Recently, with the advent of modern additive manufacturing (AM) techniques, 3D printing has attracted attention for its use in the fabrication of microfluidic devices and due to its automated, assembly-free 3D fabrication, rapidly decreasing cost, and fast-improving resolution and throughput. Here, fused filament fabrication (FFF) 3D printing was used to create microfluidic micromixers and enhance the mixing process, which has been identified as a challenge in microfluidic devices. A design of experiment (DoE) was performed on the effects of studied parameters in devices that were printed by FFF. The results of the colorimetric approach showed the effects of different parameters on the mixing process and on the enhancement of the mixing performance in printed devices. The presence of the geometrical features on the microchannels can act as ridges due to the nature of the FFF process. In comparison to passive and active methods, no complexity was added in the fabrication process, and the ridges are an inherent property of the FFF process.
17 June 2015 in Journal of Food Process Engineering
Discovery in human biology is pivoting toward high-dimensional computational analysis of 3D in vitro models, but this progress is limited by reliance on conventional cell culture techniques. Realism and data collection are hindered by the environmental instabilities and accessibility constraints of standard incubators. We introduce an automated, sealed recirculatory system that eliminates these barriers, enabling unconstrained instrument integration and infrastructure-independent scalability. By employing gas-tight sealing, a liquid-phase gas buffer and a nonporous plastic gas exchanger, our technology maintains biological stability without the compromises of open-air vessels. This design eliminates the need for CO2 incubators and prevents the evaporative drift that typically plagues conventional open-culture vessels. Operating on the benchtop outside the cell culture suite, we demonstrate that our system supports continuous, multi-week live imaging of vascular organoids while maintaining metabolic viability, structural fidelity and electrophysiological activity in brain organoids comparable to traditional in-incubator cultures.
Automation of organoid and cell culture processes is essential for achieving scalable and standardized experimentation in regenerative medicine and stem cell research. However, existing microfluidic platforms often rely on complex setups, limiting their integration within standard incubator environments. To address these challenges, we developed a compact, scalable multi-well platform featuring 3D-printed, servo-actuated disposable microvalves for fully automated media and drug exchange. This design eliminates the need for external pressure sources and control channels, providing a simplified and cost-effective solution for organoid culture. The platform integrates an internet-connected microscopy module with a motorized XYZ stage, allowing continuous, real-time imaging of individual wells directly within the incubator. It supports precise and reliable fluid handling under physiological conditions, improving throughput, reproducibility, and accessibility. We validate the platform through bench-top testing and in both mouse and human organoid models. Morphological analysis, immunohistochemistry (IHC), and qPCR demonstrate comparable viability, growth, and gene expression profiles between automated and manual culture conditions. These results establish a robust and scalable framework for fully automated organoid culture, offering a simplified and accessible alternative to conventional microfluidic systems with broad applications in regenerative medicine, drug discovery, and scalable biological screening. Abstract Figure: