In this study, we presented a simple highly sensitive sensor based on commercially available solid-core photonic crystal fiber (PCF) and surface plasmon resonance (SPR) for measuring the refractive index (RI) of analytes. The numerical simulation based on the finite element method (FEM) has been examined to compute the optical properties such as confinement loss, power spectrum, and transmission intensity of the sensor. The most sensitive and inert plasmonic materials (gold and silver) have been assumed to be coated inside the fiber with the range of analyte RI from 1.32 to 1.40. The performance of the proposed sensor has been evaluated by tracing the several optical features like wavelength sensitivity, amplitude sensitivity, resolution of the sensor, and figure of merit. As a result, the comparative study between silver and gold elements has been carried out in which the maximum sensitivity received was 1.15 μm/RIU and 1.10 μm/RIU, respectively. Whereas, on the base of power spectrum, the obtained sensitivity was 513 μm/RIU for the gold layer. Moreover, the effect of other structural parameters (air holes and plasmonic layer thickness) on the sensing performance has been taken into an account. According to the simulation analysis and results, this sensor would have a great potential in various sensing applications of biomedical and liquid refractive index.
A unique highly sensitive photonic crystal fiber, to the best of our knowledge, is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained simultaneously by examining the linear fitting curve and the movement of transmission peaks. The obtained sensitivity for temperature is 7.1 nm/°C with an exposure range of 25°C to 100°C. In contrast, the magnetic field sensitivity is 12 nm/Oe with a detection range of 160–200 Oe. In addition, the resolutions are and 5.53 Oe for temperature and magnetic field, respectively. Our inspected sensor is used to detect extremely low and high values of magnetic fields. The investigated structure is presented with simplification, compactness, easy implementation, and high sensitivity, which is expected to be a good foundation for the advancement of optical sensing devices in the future applications of industries, security, small grids, and environmental systems.
<!-- *** Custom HTML *** --> A magnetic field sensor based on the magnetic fluid injected into all the cladding air holes of the solid core photonic crystal fiber (PCF) is proposed. The 8.5 cm length of the PCF filled with magnetic fluid relates to single mode fiber to compose a Mach–Zehnder interferometer. The sensor relies on the tunable refractive index of the magnetic fluid and the characteristics of the PCF. A series of magnetic field strength is applied to this sensing structure. From the experimental results, the sensitivity of the magnetic field sensor is obtained as 7.055 × 10 − 4 dB / nT while a small change in wavelength shift is found. Due to a simple and easy fabrication technique, high sensitivity, and compactness, we are confident that the proposed sensor will find potential applications in measuring the magnetic field.
A temperature-sensor is presented based on the solid core photonic crystal fiber (PCF) infiltrated with the magnetic fluid (MF) in all or some parts of the cladding air holes with the help of the syringe injection technique. The 8.5-cm length of the proposed PCF sensor is used. A Mach–Zehnder interferometer modal is used for the detection process. The applied temperature is given in a range from 25.6°C to 100.1°C. The calculated outcome justifies that a very clear interference spectrum is obtained between the change of the refractive index of the MF and the temperature. From the experimental outputs, the temperature sensitivity of the intended PCF is −0.38 nm / ° C, and at high temperature, it achieves 0.176 nm / ° C. The MF has great sensitivity at high temperature. This proposed sensing system may find potential applications in medical science and industry.
A highly sensitive temperature probe based on a liquid cladding elliptical micro/nanofiber is proposed, which exploits a fiber loop mirror with an output port probe for remote and highly-sensitive measurements based on evanescent field coupling. The thermo-optical effective liquid cladding avoids the influence of other environmental parameters (except for temperature), while protecting the micro/nanofibers from external disturbance and contamination. This renders the sensing probe only sensitive to temperature changes, making it suitable for real-world temperature measurements. An isopropanol cladding elliptical microfiber with a diameter of 3.4 µm demonstrated a sensitivity of −16.38 nm/°C for a remote temperature measurement.