Nadia Muhammad Hussain

Ms. Nadia Muhammad Hussain

Ollscoil na Gaillimhe – University of Galway, Galway, Ireland
+3
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NHNadia Muhammad Hussain
Nadia Muhammad Hussain
Ateeq Ur RehmanAteeq Ur Rehman
Ateeq Ur Rehman
Mohamed Tahar Ben OthmanMohamed Tahar Ben Othman
Mohamed Tahar Ben Othman
JZJunaid Zafar
Junaid Zafar
HZHaroon Zafar
Haroon Zafar
Habib HamamHabib Hamam
Habib Hamam
Artificial intelligence is serving as an impetus in digital health, clinical support, and health informatics for an informed patient’s outcome. Previous studies only consider classification accuracies of cardiotocographic (CTG) datasets and disregard computational time, which is a relevant parameter in a clinical environment. This paper proposes a modified deep neural algorithm to classify untapped pathological and suspicious CTG recordings with the desired time complexity. In our newly developed classification algorithm, AlexNet architecture is merged with support vector machines (SVMs) at the fully connected layers to reduce time complexity. We used an open-source UCI (Machine Learning Repository) dataset of cardiotocographic (CTG) recordings. We divided 2126 CTG recordings into 3 classes (Normal, Pathological, and Suspected), including 23 attributes that were dynamically programmed and fed to our algorithm. We employed a deep transfer learning (TL) mechanism to transfer prelearned features to our model. To reduce time complexity, we implemented a strategy wherein layers in the convolutional base were partially trained to leave others in the frozen states. We used an ADAM optimizer for the optimization of hyperparameters. The presented algorithm also outperforms the leading architectures (RCNNs, ResNet, DenseNet, and GoogleNet) with respect to real-time accuracies, sensitivities, and specificities of 99.72%, 96.67%, and 99.6%, respectively, making it a viable candidate for clinical settings after real-time validation.

19 January 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
NHNadia Muhammad Hussain
Nadia Muhammad Hussain
MOMartin O’hAlloran
Martin O’hAlloran
BMBarry McDermott
Barry McDermott
MEMuhammad Adnan Elahi
Muhammad Adnan Elahi
Intrapartum fetal hypoxia is related to long-term morbidity and mortality of the fetus and the mother. Fetal surveillance is extremely important to minimize the adverse outcomes arising from fetal hypoxia during labour. Several methods have been used in current clinical practice to monitor fetal well-being. For instance, biophysical technologies including cardiotocography, ST-analysis adjunct to cardiotocography, and Doppler ultrasound are used for intrapartum fetal monitoring. However, these technologies result in a high false-positive rate and increased obstetric interventions during labour. Alternatively, biochemical-based technologies including fetal scalp blood sampling and fetal pulse oximetry are used to identify metabolic acidosis and oxygen deprivation resulting from fetal hypoxia. These technologies neither improve clinical outcomes nor reduce unnecessary interventions during labour. Also, there is a need to link the physiological changes during fetal hypoxia to fetal monitoring technologies. The objective of this article is to assess the clinical background of fetal hypoxia and to review existing monitoring technologies for the detection and monitoring of fetal hypoxia. A comprehensive review has been made to predict fetal hypoxia using computational and machine-learning algorithms. The detection of more specific biomarkers or new sensing technologies is also reviewed which may help in the enhancement of the reliability of continuous fetal monitoring and may result in the accurate detection of intrapartum fetal hypoxia.

4 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
NHNadia Muhammad Hussain
Nadia Muhammad Hussain
Bilal AminBilal Amin
Bilal Amin
MOMartin Ohalloran
Martin Ohalloran
AEAdnan Elahi
Adnan Elahi
Asphyxia, a leading cause of illness and death in newborns, can be improved by early detection and management. Arterial blood gas (ABG) analysis is commonly used to diagnose and manage asphyxia, but it is invasive and carries risks. Dermal interstitial fluid (ISF) is an alternative physiological fluid that can provide valuable information about a person’s health. ISF is more sensitive to severe hypoxia and metabolic disorders compared to blood, making it an attractive option for minimally invasive asphyxia detection using biosensors. However, obtaining ISF samples from humans is challenging due to ethical concerns and sampling difficulties. To address this, researchers are developing ISF-mimicking solutions as substitutes for early testing and evaluation of biosensors. This paper focuses on the development of these solutions for bench-based testing and validation of continuous asphyxia-monitoring biosensors. With an understanding of the factors influencing system quality and performance, these solutions can aid in the design of biosensors for in vivo monitoring of dermal ISF. Monitoring interstitial fluid pH levels can provide valuable insights into the severity and progression of asphyxia, aiding in accurate diagnosis and informed treatment decisions. In this study, buffer solutions were prepared to mimic the pH of ISF, and their electrical properties were analyzed. The results suggest that certain buffers can effectively mimic metabolic acidosis associated with asphyxia (pH < 7.30), while others can mimic metabolic alkalosis (pH > 7.45). Overall, this research contributes to the development of ISF-mimicking solutions and lays the groundwork for biosensor systems that monitor dermal ISF in real time.

24 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NHNadia Muhammad Hussain
Nadia Muhammad Hussain
Bilal AminBilal Amin
Bilal Amin
BMBarry McDermott
Barry McDermott
EDEoghan Dunne
Eoghan Dunne
MOMartin Ohalloran
Martin Ohalloran
AEAdnan Elahi
Adnan Elahi
Birth asphyxia is a potential cause of death that is also associated with acute and chronic morbidities. The traditional and immediate approach for monitoring birth asphyxia (i.e., arterial blood gas analysis) is highly invasive and intermittent. Additionally, alternative noninvasive approaches such as pulse oximeters can be problematic, due to the possibility of false and erroneous measurements. Therefore, further research is needed to explore alternative noninvasive and accurate monitoring methods for asphyxiated neonates. This study aims to investigate the prominent ECG features based on pH estimation that could potentially be used to explore the noninvasive, accurate, and continuous monitoring of asphyxiated neonates. The dataset used contained 274 segments of ECG and pH values recorded simultaneously. After preprocessing the data, principal component analysis and the Pan–Tompkins algorithm were used for each segment to determine the most significant ECG cycle and to compute the ECG features. Descriptive statistics were performed to describe the main properties of the processed dataset. A Kruskal–Wallis nonparametric test was then used to analyze differences between the asphyxiated and non-asphyxiated groups. Finally, a Dunn–Šidák post hoc test was used for individual comparison among the mean ranks of all groups. The findings of this study showed that ECG features (T/QRS, T Amplitude, Tslope, Tslope/T, Tslope/|T|, HR, QT, and QTc) based on pH estimation differed significantly (p < 0.05) in asphyxiated neonates. All these key ECG features were also found to be significantly different between the two groups.

1 September 2026 in IEEE Sensors Journal
Verified
Journal Article
Open access
VSV. Saroli
V. Saroli
AAA. Addabbo
A. Addabbo
NHNadia Muhammad Hussain
Nadia Muhammad Hussain
SMS. Maji
S. Maji
Emiliano SchenaEmiliano Schena
Emiliano Schena
Carlo MassaroniCarlo Massaroni
Carlo Massaroni

6 May 2022 in Authorea
Verified
Preprint
Open access
PDF file
MOMartin O'Halloran
Martin O'Halloran
NHNadia Muhammad Hussain
Nadia Muhammad Hussain
BMBarry McDermott
Barry McDermott
MEMuhammad Adnan Elahi
Muhammad Adnan Elahi
Birth asphyxia a potential cause of death is also associated with acute, and chronic morbidities. The traditional and immediate approach to monitor birth asphyxia (i.e., arterial blood gas analysis) is highly invasive and intermittent. Additionally, alternative non-invasive approaches such as pulse oximeter can be problematic, due to the possibility of false and erroneous measurements. Therefore, further research is needed to explore alternative non-invasive and accurate monitoring methods for asphyxiated neonates. This study aims to investigate prominent ECG features based on pH estimation that could potentially be used to explore non-invasive, accurate, and continuous monitoring of asphyxiated neonates. The dataset contains 274 segments of ECG and pH values recorded simultaneously. After pre-processing of data, principal component analysis and Pan-Tompkins algorithm are used for each segment, to determine the most significant ECG cycle, and to compute the ECG features. Descriptive statistics are performed to describe the main properties of the dataset. The Kruskal-Wallis nonparametric test is then used to analyse differences between the two groups. Finally, Dunn–Šidák post-hoc test is utilised for individual comparison among mean ranks of all groups. This study showed that ECG features (mainly QT, QTc, and Tslope/ T) based on pH estimation differed significantly in asphyxiated neonates.