Nandita Saha

Ms. Nandita Saha

Berlin Ultra High Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine, Berlin, Germany
+2
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Heart Rhythm
Verified
Journal Article
Open access
PLPhilipp Lacour
Philipp Lacour
PDPhi Long Dang
Phi Long Dang
FHFrank R. Heinzel
Frank R. Heinzel
APAbdul Shokor Parwani
Abdul Shokor Parwani
FBFelix Bähr
Felix Bähr
FBFlorian Blaschke
Florian Blaschke
Recent case reports and small studies have reported activation of the magnet-sensitive switches in cardiovascular implantable electronic devices (CIEDs) by the new iPhone 12 series, initiating asynchronous pacing in pacemakers and suspension of antitachycardia therapies in implantable cardioverter-defibrillators (ICDs). The purpose of this prospective single-center observational study was to quantify the risk of magnetic field interactions of the iPhone 12 with CIEDs. A representative model of each CIED series from all manufacturers was tested ex vivo. Incidence and minimum distance necessary for magnet mode triggering were analyzed in 164 CIED patients with either the front or the back of the phone facing the device. The magnetic field of the iPhone 12 was analyzed using a 3-axis Hall probe. Ex vivo, magnetic interference occurred in 84.6% with the back compared to 46.2% with the front of the iPhone 12 facing the CIED. In vivo, activation of the magnet-sensitive switch occurred in 30 CIED patients (18.3%; 21 pacemaker, 9 ICD) when the iPhone 12 was placed in close proximity over the CIED pocket and the back of the phone was facing the skin. Multiple binary logistic regression analysis identified implantation depth (95% confidence interval 0.02-0.24) as an independent predictor of magnet-sensitive switch activation. Magnetic field interactions occur only in close proximity and with precise alignment of the iPhone 12 and CIEDs. It is important to advise CIED patients to not put the iPhone 12 directly on the skin above the CIED. Further recommendations are not necessary.

14 April 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Nandita SahaNandita Saha
Nandita Saha
Andre KuehneAndre Kuehne
Andre Kuehne
JMJason Millward
Jason Millward
TEThomas Wilhelm Eigentler
Thomas Wilhelm Eigentler
LSLudger Starke
Ludger Starke
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
Thermal Magnetic Resonance (ThermalMR) is a theranostic concept that combines diagnostic magnetic resonance imaging (MRI) with targeted thermal therapy in the hyperthermia (HT) range using a radiofrequency (RF) applicator in an integrated system. ThermalMR adds a therapeutic dimension to a diagnostic MRI device. Focused, targeted RF heating of deep-seated brain tumors, accurate non-invasive temperature monitoring and high-resolution MRI are specific requirements of ThermalMR that can be addressed with novel concepts in RF applicator design. This work examines hybrid RF applicator arrays combining loop and self-grounded bow-tie (SGBT) dipole antennas for ThermalMR of brain tumors, at magnetic field strengths of 7.0 T, 9.4 T and 10.5 T. These high-density RF arrays improve the feasible transmission channel count, and provide additional degrees of freedom for RF shimming not afforded by using dipole antennas only, for superior thermal therapy and MRI diagnostics. These improvements are especially relevant for ThermalMR theranostics of deep-seated brain tumors because of the small surface area of the head. ThermalMR RF applicators with the hybrid loop+SGBT dipole design outperformed applicators using dipole-only and loop-only designs, with superior MRI performance and targeted RF heating. Array variants with a horse-shoe configuration covering an arc (270°) around the head avoiding the eyes performed better than designs with 360° coverage, with a 1.3 °C higher temperature rise inside the tumor while sparing healthy tissue. Our EMF and temperature simulations performed on a virtual patient with a clinically realistic intracranial tumor provide a technical foundation for implementation of advanced RF applicators tailored for ThermalMR theranostics of brain tumors.

1 November 2011
Verified
Conference Paper
Closed access
Shuvashis DeyShuvashis Dey
Shuvashis Dey
Nandita SahaNandita Saha
Nandita Saha
Akram AlomainyAkram Alomainy
Akram Alomainy
In this paper the design of textile antennas for materials with three different substrate permittivity ε r = 3, 2.2, 1.25 are realized. Different substrates having different permittivity affect the antenna performance in various ways. Here, Microstrip Patch Antenna is designed for narrow band WBAN (Wearable Body Area Network) at the frequency level of 2.45GHz. In this case, Dacron fabric, woven fiberglass fabric and Fleece fabric are used as antenna substrates and woven copper threads are used as the conductive part of the antenna patch. This paper demonstrates the effects of antenna bending at five different angles. Here, resonance frequency fluctuations due to impedance matching as well as effects of radiation pattern deformation due to bending at different angles are focused.

21 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BNBIlguun Nurzed
BIlguun Nurzed
Nandita SahaNandita Saha
Nandita Saha
JMJason Millward
Jason Millward
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
The literature reports highlight the transmission field (B1+) uniformity and efficiency constraints of cardiac magnetic resonance imaging (MRI) at ultrahigh magnetic fields (UHF). This simulation study proposes a 3D Metamaterial (MM) to address these challenges. The study proposes a 3D MM consisting of unit cells (UC) with split ring resonator (SRR) layers immersed in dielectric material glycerol. Implementing the proposed MM design aims to reduce the effective thickness and weight of the dielectric material while shaping B1+ and improving the penetration depth. The latter is dictated by the chosen array size, where small local UC arrays can focus B1+ and larger UC arrays can increase the field of view, at the cost of a lower penetration depth. Designing RF antennas that can effectively transmit at 21.0 T while maintaining patient safety and comfort is challenging. Using Self-Grounded Bow-Tie (SGBT) antennas in conjunction with the proposed MM demonstrated enhanced B1+ efficiency and uniformity across the human heart without signal voids. The study employed dynamic parallel transmission with tailored kT points to homogenize the 3D flip angle over the whole heart. This proof-of-concept study provides the technical foundation for human cardiac MRI at 21.0 T. Such numerical simulations are mandatory precursors for the realization of whole-body human UHF MR instruments.

20 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Nandita SahaNandita Saha
Nandita Saha
JMJason Millward
Jason Millward
CHCarl Julius Jacob Herrmann
Carl Julius Jacob Herrmann
Faezeh RahimiFaezeh Rahimi
Faezeh Rahimi
HHHaopeng Han
Haopeng Han
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
Case reports indicate that magnets in smartphones could be a source of electromagnetic interference (EMI) for active implantable medical devices (AIMD), which could lead to device malfunction, compromising patient safety. Recognizing this challenge, we implemented a high-fidelity 3D magnetic field mapping (spatial resolution 1 mm) setup using a three-axis Hall probe and teslameter, controlled by a robot (COSI Measure). With this setup, we examined the stray magnetic field of an iPhone 13 Pro, iPhone 12, and MagSafe charger to identify sources of magnetic fields for the accurate risk assessment of potential interferences with AIMDs. Our measurements revealed that the stray fields of the annular array of magnets, the wide-angle camera, and the speaker of the smartphones exceeded the 1 mT limit defined by ISO 14117:2019. Our data-driven safety recommendation is that an iPhone 13 Pro should be kept at least 25 mm away from an AIMD to protect it from unwanted EMI interactions. Our study addresses safety concerns due to potential device–device interactions between smartphones and AIMDs and will help to define data-driven safety guidelines. We encourage vendors of electronic consumer products (ECP) to provide information on the magnetic fields of their products and advocate for the inclusion of smartphones in the risk assessment of EMI with AIMDs.

2 February 2026 in Advanced Materials
Verified
Journal Article
Open access
Nandita SahaNandita Saha
Nandita Saha
BNBIlguun Nurzed
BIlguun Nurzed
MBMostafa Berangi
Mostafa Berangi
Andre KuehneAndre Kuehne
Andre Kuehne
HWHelmar Waiczies
Helmar Waiczies
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
A metamaterial‐integrated radio frequency antenna (MTMA), implemented in planar and bend configurations, enables high‐resolution MRI of the eye, orbit, and occipital brain at 7.0 T. Its dual‐layer co‐planar architecture integrates a two‐channel transceive loop with a metamaterial layer composed of subwavelength epsilon‐negative unit cells. These unit cells were custom‐designed based on classical split‐ring resonators for operation at 7.0 T. Electromagnetic simulations, including human voxel models, guided the design and characterization of the MTMA's electromagnetic behavior. Both MTMA configurations were benchmarked against conventional loop coil arrays in phantoms and in vivo for experimental validation, demonstrating enhanced transmit (B 1 + ) efficiency and receive sensitivity enabled by the metamaterial layer through resonant near‐field coupling. MRI safety was verified through SAR simulations, bio‐thermal modeling, Magnetic Resonance thermometry, and fiber‐optic sensors, confirming compliance with safety guidelines. The Bend‐MTMA enabled in vivo human MRI of the eye and orbit in healthy volunteers, including B 1 + mapping, and provided diagnostic T 1 ‐ and T 2 ‐weighted imaging in volunteers with retinal pathology and sinus cysts, demonstrating clinical applicability. The Planar‐MTMA enabled occipital lobe MRI in human volunteers, achieving superior signal coverage and transmit performance. The modular unit cell design enables tuning across MRI magnetic field strengths, establishing a clinically translatable metamaterial‐integrated antenna platform for ocular and neurological imaging.