Nisrine NASERI

Dr. Nisrine NASERI

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
Imad AboudrarImad Aboudrar
Imad Aboudrar
SHSoumia El Hani
Soumia El Hani
MHMohamed Saleck Heyine
Mohamed Saleck Heyine
NNNisrine NASERI
Nisrine NASERI
This work presents linear and nonlinear control strategies applied to a grid‐connected multiple‐source renewable energy system (wind and photovoltaic), in order to extract the maximum power and to enhance the control of the active and reactive powers. A new robust control strategy known as the active disturbance rejection control (ADRC) is proposed and applied to the hybrid renewable energy system (HRES), and it is based on the extended state observer (ESO) which allows us to estimate the internal and external disturbances such as modeling errors and parameter variations. The studied system consists of two conversion chains which are linked via a common DC bus and interconnected to the grid through a voltage source inverter (VSI); the first chain consists of a PV system and a DC‐DC boost converter, and the second chain consists of a direct‐driven wind turbine, permanent magnetic synchronous generator (PMSG), and of a AC/DC rectifier converter. The extraction of maximum power from the PV system and the wind energy conversion system is ensured by using the voltage based perturb and observe (VPO) and the optimal torque control (OTC) MPPT techniques, respectively. The ADRC technique is utilized to control the active and reactive powers by acting on the grid currents. In order to verify and validate the effectiveness of the proposed control strategy, a detailed model of the studied system is designed and evaluated under the MATLAB/Simulink software. The simulation results prove the effectiveness of the MPPT techniques in terms of maximum power extraction during the variation in the environmental conditions. Additionally, the regulation of active and reactive powers is ensured by ADRC, and the system is operating at a unity power factor. Moreover, it is demonstrated that the suggested strategy is efficient in terms of fast tracking and robustness to internal and external disturbances compared to the classical PI controller.

14 June 2022 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
NNNisrine NASERI
Nisrine NASERI
SHSoumia El Hani
Soumia El Hani
KHKhadija El Harouri
Khadija El Harouri
HMHamza Mediouni
Hamza Mediouni

14 August 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
Imad AboudrarImad Aboudrar
Imad Aboudrar
SHSoumia El Hani
Soumia El Hani
HMHamza Mediouni
Hamza Mediouni
NNNisrine NASERI
Nisrine NASERI
ADAmina Daghouri
Amina Daghouri
Low voltage ride-through is considered as one of the key technologies for the operation of grid-connected photovoltaic power generation systems. At present, the most used control methods are based mainly on PI controllers, and their robustness results are still unsatisfactory. In contrast, this article introduces a new robust control strategy that uses the compensation effect of “total disturbance” before affecting the system; this control strategy is called Active Disturbance Rejection Control (ADRC) method. In addition, most of the controllers use the standard SRF PLL to achieve the phase lock and grid synchronization. However, when the grid voltage is distorted or other unbalanced, it is necessary to use the positive sequence voltage component of the fundamental wave as a reference, but the component of the negative sequence cannot be effectively filtered because of its narrow bandwidth, and then, accurate phase lock cannot be achieved, which may cause a failure. In this purpose, a Double Second Order Generalized Integrator based Frequency Locked Loop (DSOGI-FLL) is proposed and used to improve the system operating performance and non-off-line capability. In order to confirm the robustness of the proposed control strategies, a multiple simulations tests were done by utilizing the Matlab/Simulink software. The results have demonstrated the superiority of the proposed methods and their robustness to symmetrical and unsymmetrical faults.

1 December 2018
Verified
Conference Paper
Closed access
NNNisrine NASERI
Nisrine NASERI
SHSoumia El Hani
Soumia El Hani
Ahmed AghmadiAhmed Aghmadi
Ahmed Aghmadi
KHKhadija El Harouri
Khadija El Harouri
MHMohamed Salek Heyine
Mohamed Salek Heyine
HMHamza Mediouni
Hamza Mediouni
In the last few decades, due to pollution increasing, scientists try to optimize and encourage renewable energies unit production. Fuel cell is a energy of the future that provides a safe, efficient and clean electrical energy. This paper presents the Proton Exchange Membrane Fuel Cell (PEMFC) static and dynamic model with the Perturb and Observe Maximum Power Point Tracker (P&O MPPT) method. Many advantages are considered to fuel cell, like low emissions, high efficiency, noiselessness and no vibration. The equivalent electrical circuit of the PEM fuel cell unit is developed and implemented in the software MATLAB/Simulink.

4 April 2023 in Designs
Verified
Journal Article
Open access
PDF file
KHKhadija El Harouri
Khadija El Harouri
SHSoumia El Hani
Soumia El Hani
NNNisrine NASERI
Nisrine NASERI
Elhoussin ElbouchikhiElhoussin Elbouchikhi
Elhoussin Elbouchikhi
Mohamed BenbouzidMohamed Benbouzid
Mohamed Benbouzid
SSSondes Skander-Mustapha
Sondes Skander-Mustapha
Electric vehicles (EV) and photovoltaic (PV) systems are increasingly becoming environmentally friendly and more affordable solutions for consumers. This article discusses the integration of PV and EV in a residential system to meet the requirements of residential loads taking into account the PV supplied power, availability and the state of charge (SOC) of EVs. A hybrid control model has been proposed to control the residential system. The combined PI-Fuzzy logic controller is employed to control the buck-boost bi-directional converter. The DC-AC grid-side converter is controlled by the ADRC controller. The effectiveness of PI-Fuzzy logic controller in reducing voltage and current ripples and ADRC controller in rejecting disturbances is demonstrated in each case. A rule-based energy management strategy has been proposed to control the flow of energy between the components of the residential system. The suggested energy management system (EMS) covers every scenario that might occur. Whether the EV is linked to the home or not, and also takes into account the owner using the EV in an emergency situation. The EV operates in two modes, Home-to-Vehicle (H2V) mode and Vehicle-to-Home (V2H) mode, depending on the power produced by the PV and the conditions related to the EV. All possible scenarios are tested and validated. The simulation results show that the proposed EMS is a reliable solution that can reduce the power grid intervention.

28 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
NNNisrine NASERI
Nisrine NASERI
SHSoumia El Hani
Soumia El Hani
Mohamed MachmoumMohamed Machmoum
Mohamed Machmoum
Elhoussin ElbouchikhiElhoussin Elbouchikhi
Elhoussin Elbouchikhi
ADAmina DAGHOURI
Amina DAGHOURI
Investing in green hydrogen systems has become a global objective to achieve the net-zero emission goal. Therefore, it is seen as the primary force behind efforts to restructure the world’s energy, lessen our reliance on gas, attain carbon neutrality, and combat climate change. This paper proposes a power management for a net zero emission PV microgrid-based decentralized green hydrogen system. The hybrid microgrid combines a fuel cell, battery, PV, electrolyzer, and compressed hydrogen storage (CHSU) unit aimed at power sharing between the total components of the islanded DC microgrid and minimizing the equivalent hydrogen consumption (EHC) by the fuel cell and the battery. In order to minimize the EHC and maintain the battery SOC, an optimization-based approach known as the Equivalent Consumption Minimization Strategy (ECMS) is used. A rule-based management is used to manage the power consumed by the electrolyzer and the CHSU by the PV system in case of excess power. The battery is controlled by an inverse droop control to regulate the dc bus voltage and the output power of the PV system is maximized by the fuzzy logic controller-based MPPT. As the hybrid microgrid works in the islanded mode, a two-level hierarchical control is applied in order to generate the voltage and the frequency references. The suggested energy management approach establishes the operating point for each system component in order to enhance the system’s efficiency. It allows the hybrid system to use less hydrogen while managing energy more efficiently.