Pedro Castro-Martins

Dr. Pedro Castro-Martins

ISEP-School of Engineering, Polytechnic Institute of Porto, Porto, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in Heliyon
Verified
Journal Article
Open access
Pedro Castro-MartinsPedro Castro-Martins
Pedro Castro-Martins
MMM. Arcelina Marques
M. Arcelina Marques
LCLuís Coelho
Luís Coelho
MVMário Vaz
Mário Vaz
João Santos BaptistaJoão Santos Baptista
João Santos Baptista
Loss of cutaneous protective sensation and high plantar pressures increase the risk for diabetic foot patients. Trauma and ulceration are imminent threats, making assessment and monitoring essential. This systematic review aims to identify systems and technologies for measuring in-shoe plantar pressures, focusing on the at-risk diabetic foot population. A systematic search was conducted across four electronic databases (Scopus, Web of Science, PubMed, Oxford Journals) using PRISMA methodology, covering articles published in English from 1979 to 2024. Only studies addressing systems or sensors exclusively measuring plantar pressures inside the shoe were included. A total of 87 studies using commercially available devices and 45 articles proposing new systems or sensors were reviewed. The prevailing market offerings consist mainly of instrumented insoles. Emerging technologies under development often feature configurations with four, six or eight resistive sensors strategically placed within removable insoles. Despite some variability due to the inherent heterogeneity of human gait, these devices assess plantar pressure, although they present significant differences between them in measurement results. Individuals with diabetic foot conditions appears exhibit elevated plantar pressures, with reported peak pressures reaching approximately 1000 kPa. The results also showed significant differences between the diabetic and non-diabetic groups. Instrumented insoles, particularly those incorporating resistive sensor technology, dominate the field. Systems employing eight sensors at critical locations represent a pragmatic approach, although market options extend to systems with up to 960 sensors. Differences between devices can be a critical factor in measurement and highlights the importance of individualized patient assessment using consistent measurement devices.

14 February 2024 in Heliyon
Verified
Journal Article
Open access
Pedro Castro-MartinsPedro Castro-Martins
Pedro Castro-Martins
MMM. Arcelina Marques
M. Arcelina Marques
LCLuís Coelho
Luís Coelho
MVMário Vaz
Mário Vaz
JCJosé Torres Costa
José Torres Costa
The development of ulcers in the plantar region of the diabetic foot originates mainly from sites subjected to high pressure. The monitoring of these events using maximum allowable pressure thresholds is a fundamental procedure in the prevention of ulceration and its recurrence. The aim of this review was to identify data in the literature that reveal an objective threshold of plantar pressure in the diabetic foot, where pressure is classified as promoting ulceration. The aim is not to determine the best and only pressure threshold for ulceration, but rather to clarify the threshold values most used in clinical practice and research, also considering the devices used and possible applications for offloading plantar pressure. A systematic review. The search was performed in three electronic databases, by the PRISMA methodology, for studies that used a pressure threshold to minimize the risk of ulceration in the diabetic foot. The selected studies were subjected to eligibility criteria. Twenty-six studies were included in this review. Seven thresholds were identified, five of which are intended for the inside of the shoe: a threshold of average peak pressure of 200 kPa; 25 % and 40-80 % reduction from initial baseline pressure; 32-35 mm Hg for a capillary perfusion pressure; and a matrix of thresholds based on patient risk, shoe size and foot region. Two other thresholds are intended for the barefoot, 450 and 750 kPa. The threshold of 200 kPa of pressure inside the shoe is the most agreed upon among the studies. Regarding the prevention of ulceration and its recurrence, the efficacy of the proposed threshold matrix and the threshold of reducing baseline pressure by 40-80 % has not yet been evaluated, and the evidence for the remaining thresholds still needs further studies. Some heterogeneity was found in the studies, especially regarding the measurement systems used, the number of regions of interest and the number of steps to be considered for the threshold. Even so, this review reveals the way forward to obtain a threshold indicative of an effective steppingstone in the prevention of diabetic foot ulcer.

10 July 2022
Verified
Conference Paper
Closed access
Pedro Castro-MartinsPedro Castro-Martins
Pedro Castro-Martins
CSCarolina Silva
Carolina Silva
JOJULIANA OLIVEIRA
JULIANA OLIVEIRA
MMM. Arcelina Marques
M. Arcelina Marques
The search for more practical and economically advantageous solutions to produce flexible and printable pressure sensors, is giving rise to new approaches with promising results. The production of conductive and piezoresistive inks for application on flexible and stretchable substrates is a sign of this evolution. In this paper, we propose to analyze the results of some calibration tests, performed with pressure-sensitive piezoresistive sensors screen-printed on PET and textile substrates. The results showed that these sensors generally follow a trend with a strong approximation to the linear model. The textile sensor is the most linear (R2 = 0.99), and PET sensor (S1) has a higher sensitivity (40.4 mV/kPa) than the other sensors. Results obtained are, in general, within the expected behavior for the piezoresistive ink used and allowed for comparing between sensors printed in PET and textile substrates. A positive factor to consider lies in the possibility of using the screen-printing technology on different substrates, preferably in textile fabric.

31 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Pedro Castro-MartinsPedro Castro-Martins
Pedro Castro-Martins
Luis Pinto-CoelhoLuis Pinto-Coelho
Luis Pinto-Coelho
Raul CampilhoRaul Campilho
Raul Campilho
Diabetic foot is a serious complication that poses significant risks for diabetic patients. The resulting reduction in protective sensitivity in the plantar region requires early detection to prevent ulceration and ultimately amputation. The primary method employed for evaluating this sensitivity loss is the 10 gf Semmes–Weinstein monofilament test, commonly used as a first-line procedure. However, the lack of calibration in existing devices often introduces decision errors due to unreliable feedback. In this article, the mechanical behavior of a monofilament was analytically modeled, seeking to promote awareness of the impact of different factors on clinical decisions. Furthermore, a new device for the automation of the metrological evaluation of the monofilament is described. Specific testing methodologies, used for the proposed equipment, are also described, creating a solid base for the establishment of future calibration guidelines. The obtained results showed that the tested monofilaments had a very high error compared to the 10 gf declared by the manufacturers. To improve the precision and reliability of assessing the sensitivity loss, the frequent metrological calibration of the monofilament is crucial. The integration of automated verification, simulation capabilities, and precise measurements shows great promise for diabetic patients, reducing the likelihood of adverse outcomes.

19 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Pedro Castro-MartinsPedro Castro-Martins
Pedro Castro-Martins
MMM. Arcelina Marques
M. Arcelina Marques
Luis Pinto-CoelhoLuis Pinto-Coelho
Luis Pinto-Coelho
PFPedro Fonseca
Pedro Fonseca
Mário VazMário Vaz
Mário Vaz
Plantar pressure monitoring is decisive in injury prevention, especially in at-risk populations such as people with diabetic foot. In this context, innovative solutions such as pneumatic insoles can be essential in plantar pressure management. This study describes the development of a variable pressure system that promotes the monitoring, stabilization, and offloading of plantar pressure through a pneumatic insole. This research was also intended to evaluate its ability to redistribute plantar pressure, reduce peak pressure in both static and dynamic conditions, and validate its pressure measurements by comparing the results with those obtained from a pedar® insole. Tests were carried out under both static and dynamic conditions, before and after the pressure stabilization process by air cells and the subsequent pressure offloading. During the validation process, methods were used to evaluate the agreement between measurements obtained by the two systems. The results of the static test showed that pressure stabilization reduced pressure on the heel by 32.43%, distributing it to the metatarsals and toes. After heel pressure offloading, the reduction reached 42.72%. In the dynamic test, despite natural dispersion of the measurements, a trend to reduce the peak pressure in the heel, metatarsals, and toes was observed. Agreement analysis recorded 96.32% in the static test and 94.02% in the dynamic test. The pneumatic insole proved effective in redistributing and reducing plantar pressure, with more evident effects in the static test. Its agreement with the pedar® system reinforces its reliability as a tool for measuring and managing plantar pressure, representing a promising solution for preventing plantar lesions.

19 October 2021
Verified
Book Chapter
Closed access
PDF file
Pedro Castro-MartinsPedro Castro-Martins
Pedro Castro-Martins
LCL. Coelho
L. Coelho
The loss of protective sensitivity in the diabetic foot requires an early diagnosis due to the imminent possibility of ulceration and amputation of the affected limb. In screening for loss of protective sensitivity, the 10 gf Semmes-Weinstein monofilament (SWM) is the most widely used first-line instrument. However, this decisive instrument lacks calibration and quality control. In this paper we present a study to objectively evaluate the SWM performance using a specific measuring equipment. We conducted a metrological verification of three monofilaments using an automated method under controlled conditions. The obtained results revealed that the SWM compression force depends on the number of repeated uses, the ambient temperature, and the displacement speed and contact with the patient’s skin. In fact, all the SWMs showed dependence on external factors and evidenced relative errors between 14 % and 167 %, values that can be considered critical to discriminate the pathology and its evolution.