Anchor cables often break in various forms. Tensile failure can be resisted by using high-strength materials, while there is no good solution for shear failure. A new supporting structure called Anchor Cable and C-shaped tube that can bear the transverse shear force was invented and a preliminary introduction to the mechanism of the structure is given. Field investigations and in-situ stress tests were carried out on the panel 3210 in the Nanguan Mine. The failure modes of the surrounding rock and cables and the in-situ stress test results show that the working face is obviously affected by the horizontal stress. Thus, a new full-section anchor cable and C-shaped tube support scheme were proposed. The results of FLAC3D show that the new scheme is excellent in controlling the surface convergence and plastic zone extension. The rationality of the scheme was verified by two-and-a-half months of monitoring. Compared with the original scheme, the amount of surface displacement was at least 20% smaller, and the time for the displacement to reach equilibrium was at least 27.4% shorter. The surface of the roadway is flat without supporting material damaging. The new scheme is worth popularizing in similar working conditions.
Deep roadway deformation due to soft rock, rock dip, and horizontal tectonic stress is uneven and asymmetrical primarily in large loose zones. Traditional anchor support is influenced by the yield strength and shear strength of the anchors and has a limited prestress capacity or shear resistance. When the roadway roof is laminated rock or when the roadway passes through layered rock or rock interfaces, interlayer sliding commonly occurs, which can easily lead to anchor cables being sheared off. The tape tunnel in the Zhengling Mine passes through several rock strata and requires anchors to achieve a high shear resistance and prestress. To solve these problems, an anchor cable and C-shaped tube that can bear lateral shear forces were developed, and a full-section anchor cable and C-shaped tube support system were created based on extruded arch theory. Numerical results from FLAC3D show that the new scheme effectively controls surface convergence and plastic zone extension. Field tests have demonstrated that the amount of surface displacement was at least 42 smaller in the new support scheme. The extruded arch formed by the highly prestressed anchor cable and concrete spray layer can effectively control the bulking load within the loose zone, and the ACC effectively resists interlayer shear.
The free section of prestressed anchor cable is a weak part of support. A new supporting structure named Anchor Cable and C‐Shaped Tube, which can bear transverse shear force, solves the problem that rock bolt and anchor cable are prone to shear failure in the free section and also solves the contradiction between high preload and low shear bearing capacity of support materials. Double‐shear tests of Anchor Cable and C‐Shaped Tube with smooth joint planes were carried out. Double‐shear tests were carried out on the anchor cables with the diameter of 21.6 mm and the same type of Anchor Cable and C‐Shaped Tube under different preload conditions. The influence of the preload on the shear performance of supporting materials and the enhancement effect of Anchor Cable and C‐Shaped Tube supporting structure on the shear performance of anchor cables were analyzed. The test results confirm that Anchor Cable and C‐Shaped Tube can improve the transverse shear resistance of the supporting material and increase the axial ultimate bearing capacity of the anchor cable during the shearing process. It is found that, during the double‐shear test, the fracture form of the supporting materials is tensile fracture, and when it is sheared, Anchor Cable and C‐Shaped Tube can reduce the stress concentration of the interaction between the joint surface and the surrounding rock and reduce the damage to the surrounding rock.
Fractured rock masses are extremely common in geological engineering. In order to improve the stability of surrounding rock under dynamic conditions, new grouting materials and their reinforcement characteristics were studied. In this paper, split Hopkinson pressure bar (SHPB) tests were employed to analyze the dynamic mechanical and failure characteristics of grouted fractured rock with nano-grouting material (nano-grouted fractured rock). Simultaneously, high-speed camera tests were utilized to examine the macroscopic dynamic deformation and failure processes. The following was found: (1) Under a relatively low impact air pressure of 0.1 MPa, the mechanical properties of nano-grouted fractured rock are considerably better than those of traditional cement-based grouted rock. However, when the impact air pressure is increased to 0.3 MPa, the superiority of nano-grouting material diminishes, the possible cause of which is explained from the microscopic point of view. This means the nano-grouting material is more suitable for low-engineering-disturbance conditions (e.g., shield construction). (2) Both for the nano- and superfine cement grouting material, the impact fractures initially emerge at the two ends of the original grouted fracture and form a pair of parallel lines. (3) In comparison with 0.1 MPa, the impact pressure of 0.3 MPa leads to more severe damage to the rock specimen. These findings contribute to a deeper understanding of the behavior of nano-grouted fractured rock under dynamic loading and provide valuable insights for relevant engineering applications in the field of rock mechanics and grouting technology.
Metallurgical equipment foundations exposed to prolonged 300–500 °C environments are subject to explosion risks, necessitating materials that are resistant to thermo-shock-coupled loads. This study investigated the real-time dynamic compressive behavior of high-performance concrete (HPC) reinforced with steel fibers (SFs), polypropylene fibers (PPFs), polyvinyl alcohol fibers (PVAFs), and their hybrid systems under thermo-shock coupling using real-time high-temperature (200–500 °C) SHPB tests. The results revealed temperature-dependent dynamic responses: SFs exhibited a V-shaped trend in compressive strength evolution (minimum at 400 °C), while PPFs/PVAFs showed inverted V-shaped trends (peaking at 300 °C). Hybrid systems demonstrated superior performance: SF-PVAF achieved stable dynamic strength at 200–400 °C (dynamic increase factor, DIF ≈ 1.65) due to synergistic toughening via SF bridging and PVAF melt-induced pore energy absorption. Microstructural analysis confirmed that organic fiber pores and SF crack-bridging collaboratively optimized failure modes, reducing brittle fracture. A temperature-adaptive design strategy is proposed: SF-PVAF hybrids are prioritized for temperatures of 200–400 °C, while SF-PPF combinations are recommended for 400–500 °C environments, providing critical guidance for explosion-resistant HPC in extreme thermal–industrial settings.