PHONSIT SANTIPRAPAN

Dr. PHONSIT SANTIPRAPAN

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
PHONSIT SANTIPRAPANPHONSIT SANTIPRAPAN
PHONSIT SANTIPRAPAN
KAKongpan Areerak
Kongpan Areerak
KAK-L. Areerak
K-L. Areerak
KAK-N. Areerak
K-N. Areerak
Load changing behavior effects the performance of a compensating current control for an active power filter. Thus, in this paper, adaptive proportional-resonant controller is proposed. A fuzzy logic algorithm is applied as the adaptive gain mechanism for the proportional-resonant controller. The new design technique for the proposed controller is fully presented in this paper. The criterion for designing the adaptive proportional-resonant controller follows the root locus technique and the modulation index analysis of the switching technique. The overall control strategy is implemented using an eZdspTM F28335 board. For testing in the laboratory, balanced and unbalanced nonlinear loads are considered. Experimental results confirm that the adaptive proportional-resonant controller designed by the new approach can provide good performance compared with the PI and PR controllers. Moreover, the proposed controller can still mitigate the harmonics even if the nonlinear loads are suddenly changed.

5 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
CPCHAKRIT PANPEAN
CHAKRIT PANPEAN
KAKongpol Areerak
Kongpol Areerak
PHONSIT SANTIPRAPANPHONSIT SANTIPRAPAN
PHONSIT SANTIPRAPAN
KAKongpan Areerak
Kongpan Areerak
SYSeang Shen Yeoh
Seang Shen Yeoh
An electric multiple unit (EMU) high-speed train is the dynamic load that degrades the power quality in an electric railway system. Therefore, a power quality improvement system using an active power filter (APF) must be considered. Due to the oscillating load current in the dynamic load condition, a fast and accurate harmonic current-tracking performance is required. As such, this paper proposes the design of a model predictive control (MPC) since the minimization of cost function in the MPC process can suitably determine APF switching states. The design technique of MPC is based on the APF mathematical model. This controller was designed to compensate the time delay in the digital control. Moreover, the synchronous detection (SD) method applied the reference current calculations, as shown in this paper. To verify the proposed MPC, the overall control of APF was implemented on a eZdsp F28335 board by using the hardware-in-the-loop technique. The testing results indicated that the proposed MPC can provide a fast and accurate harmonic current-tracking response compared with the proportional-integral controller. In the load changing condition, the MPC was still effective in providing a good result after compensation. The percentage of total harmonic distortion, the percentage current unbalance factor, and the power factor would also be kept within the IEEE Standard 519 and IEEE Standard 1459.

1 October 2020 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
PHONSIT SANTIPRAPANPHONSIT SANTIPRAPAN
PHONSIT SANTIPRAPAN
ABApidet Booranawong
Apidet Booranawong
KAKongpol Areerak
Kongpol Areerak
HSHiroshi Saito
Hiroshi Saito
Load changing behaviour significantly affects the compensating current control performance of active power filters (APFs). Owing to this effect, harmonic currents at the source can significantly degrade the power quality of the system. This work proposes an adaptive repetitive controller based on a fuzzy logic algorithm to improve current control performance. In addition, a new design approach to fuzzy membership functions is also proposed. The design concept for the adaptive repetitive controller follows a stability analysis of the compensating current control and a mathematical model of the APF. In experimental testing, a power system was implemented with the proposed controller using the processor ‐ in ‐ the ‐ loop technique on an eZdsp™ F28335 board and the MATLAB / Simulink programme. The experimental results indicated that the proposed adaptive repetitive controller would provide better harmonic current‐tracking performance compared with conventional repetitive controllers. Also, the APF used in conjunction with the proposed controller would efficiently mitigate harmonic currents even where non‐linear loads changed. Moreover, the percentage of total harmonic distortion would be maintained within the IEEE standard 519–2014.

8 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
KCKrittapas Chaiyaphun
Krittapas Chaiyaphun
PHONSIT SANTIPRAPANPHONSIT SANTIPRAPAN
PHONSIT SANTIPRAPAN
KAKongpol Areerak
Kongpol Areerak
The distorted supply voltage degrades the control performance of a unified power quality conditioner (UPQC). This problem causes incorrect calculations in the harmonic identification and reference signal generation processes. This paper proposes a modified harmonic identification of the UPQC. The reference compensating current calculation for the shunt active power filter (shunt APF) is developed using the sliding window with the Fourier analysis (SWFA) method. In addition, the variable power angle control (PAC) is applied to operate the reference signal generation of the series APF and the shunt APF of the UPQC. Under the distorted voltage and nonlinear load conditions, the proposed approach can provide accurate reference compensating signals and successfully share the load reactive power compensation between the shunt APF and the series APF. In this work, a three-phase, three-wire power system with linear and nonlinear loads was implemented. The proposed method was validated using the processor-in-the-loop technique on an eZdsp™ F28335 board and the MATLAB/Simulink program. The testing results indicated that SWFA has excellent filtering performance and enhances harmonic identification compared to the operation without any filter or with low pass filters (LPF). With the proposed approach, the percentage of total harmonic distortion of voltage and current could be maintained within the IEEE519-2022 standard, and the magnitude of the RMS voltage across the load was in the recommended range specified by ANSI C84.1-2016.

1 March 2017
Verified
Conference Paper
Closed access
PHONSIT SANTIPRAPANPHONSIT SANTIPRAPAN
PHONSIT SANTIPRAPAN
KAKongpol Areerak
Kongpol Areerak
KAKongpan Areerak
Kongpan Areerak
This paper presents the design approach of the proportional plus resonant control for active power filter in three-phase four-wire system. The hardware implementation is used to test the harmonic elimination using an active power filter. The experimental results confirm that the proportional plus resonant controller can provide good performance in dynamic load condition.

14 August 2025 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
NKNatthawut Kongchoo
Natthawut Kongchoo
CPChakrit Panpean
Chakrit Panpean
SUSasiya Udomsuk
Sasiya Udomsuk
WWWarit Wichakool
Warit Wichakool
MSMongkol Saejia
Mongkol Saejia
PHONSIT SANTIPRAPANPHONSIT SANTIPRAPAN
PHONSIT SANTIPRAPAN