Premraj Saini

Mr. Premraj Saini

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2025 in Journal of Human Sport and Exercise
Verified
Journal Article
Open access
PDF file
SKSandeep Kumar
Sandeep Kumar
PPPunam Pradhan
Punam Pradhan
TMTadang Minu
Tadang Minu
Premraj SainiPremraj Saini
Premraj Saini
TBTim S. Babu
Tim S. Babu
Rohit Kumar ThapaRohit Kumar Thapa
Rohit Kumar Thapa
The hook punch is a fundamental technique in boxing, requiring coordinated activation of upper- and lower-limb muscles to generate maximal force and speed. While previous studies have analysed muscle activation in straight punches, research on hook punches remains limited. This study aimed to examine the peak activation (PA) and average rectified value (ARV) of seven upper- and lower-body muscles during four distinct hook punch techniques and compare activation patterns between Southpaw (SP) and Orthodox (OD) stance boxers. Twelve elite male boxers (SP: n = 8, OD: n = 4) participated in this study. Surface electromyography recorded PA and ARV of the biceps brachii (BB), triceps brachii (TB), anterior deltoid (AD), latissimus dorsi (LD), biceps femoris (BF), rectus femoris (RF), and medial gastrocnemius (MG) during four hook punch techniques: lead-arm hook to the head (LAHH), lead-arm hook to the body (LAHB), rear-arm hook to the head (RAHH), and rear-arm hook to the body (RAHB). The independent t-test and Wilcoxon test compared stance groups, while the paired t-test was used to determine intra-technique differences. No significant differences in PA or ARV were found between SP and OD, except for RF activation during LAHB (p = .038). Significant intra-technique differences were observed in LD, RF, and MG activation. In conclusion, no differences in muscle activation were observed between SP and OD stances, except for the rectus femoris during the LABH. Between punch techniques, variation in muscle activation was observed, implying differences in strategies used.

10 December 2025 in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Verified
Journal Article
Closed access
Premraj SainiPremraj Saini
Premraj Saini
ASAnugrah Suresh
Anugrah Suresh
SNSandy Nair
Sandy Nair
Badicu GeorgianBadicu Georgian
Badicu Georgian
Rodrigo Ramirez-CampilloRodrigo Ramirez-Campillo
Rodrigo Ramirez-Campillo
Rohit Kumar ThapaRohit Kumar Thapa
Rohit Kumar Thapa
The aim of this study was to investigate the validity and test-retest reliability of an IMU ( Output V2 ) compared to a force plate (Kistler, Winterthur, Switzerland) for measuring countermovement jump (CMJ) and drop jump (DJ) performance metrics. In a randomized crossover study design, male athletes ( n = 17; age: 22.3 ± 2.3 years) performed three CMJ and DJ maximal effort trials, with the force plate and the IMU concurrently recording jump performance data. The intraclass correlation coefficient (ICC (consistency)), Cronbach’s alpha, coefficient of variation (CV), and standard error of measurement (SEM) were calculated to determine test-retest reliability. Validity (i.e., between-instruments comparison) was assessed using unpaired t -test, Pearson correlation, ICC (absolute agreement), concordance correlation coefficient (CCC), and Bland-Altman plots. Test-retest reliability of IMU was good to excellent for both tools (ICC lower limit ≥ 0.857, Cronbach’s α ≥ 0.977, CV ≤ 2.3%, relative SEM ≤ 2.72%). Compared to the force plate, the IMU measured similar (between-instruments p > 0.05) CMJ height, DJ height, reactive strength index, and DJ contact time, with almost perfect Pearson correlations ( r ≥ 0.983), substantial CCC ( ρ c ≥ 0.952), and good to excellent ICC values (≥0.860). Bland–Altman plots showed negligible bias and strong agreement. The IMU Output V2 was found to be valid and reliable when compared to a force plate for measuring CMJ and DJ performance metrics. The Output V2 IMU’s cost-effectiveness, portability, and ease of use via mobile devices make it a practical alternative for field assessments.

1 June 2026 in Human Movement
Verified
Journal Article
Closed access
AKAvinash Kharel
Avinash Kharel
MHMadin Hina
Madin Hina
JBJateen Baruah
Jateen Baruah
Premraj SainiPremraj Saini
Premraj Saini
Michal WilkMichal Wilk
Michal Wilk
Rohit Kumar ThapaRohit Kumar Thapa
Rohit Kumar Thapa
Purpose: Post-activation performance enhancement (PAPE) is a phenomenon that can improve short-term performance in combat sports like judo. However, the optimal rest interval between conditioning activities and judo performance has not been determined, especially for young female judokas. This study examined the acute effects of two different rest intervals (3-min vs. 8-min) on judo-specific performance. Methods: Fifteen female judokas (age: 14.6 ± 1.8 years) participated in a randomised crossover study involving four conditions: a controlled condition with a judo-specific warm-up and experimental conditions including ballistic jumps combined with the judo-specific warm-ups, each followed by 3-min or 8-min rest intervals before performing the Special Judo Fitness Test (SJFT). Countermovement jump (CMJ) height, heart rate (HR), handgrip strength, and rating of perceived exertion (RPE) were assessed post-SJFT. Results: No significant differences in SJFT performance were observed across conditions (p > 0.05). However, immediate (p = 0.018; Hedge’s g = 0.77) and maximum HR (p = 0.021; Hedge’s g = 0.60) were significantly higher in the 3-min experimental condition, indicating increased cardiovascular strain. Right-hand grip strength was also significantly higher in the 3-min experimental condition (p = 0.043; Hedge’s g = 0.45). No significant differences were observed in CMJ height, left handgrip strength, or RPE (p > 0.05). Conclusions: Neither 3-min nor 8-min rest interval enhanced judo-specific performance following ballistic conditioning activities in young female judokas. Moreover, shorter rest periods may impose greater cardiovascular demands. Future research should explore alternative conditioning activity protocols and individualised recovery strategies to optimise PAPE responses in female judokas.

1 January 2026 in Women in Sport and Physical Activity Journal
Verified
Journal Article
Closed access
TBTim S. Babu
Tim S. Babu
Premraj SainiPremraj Saini
Premraj Saini
SRShiny Raizada
Shiny Raizada
Danny LumDanny Lum
Danny Lum
Rohit Kumar ThapaRohit Kumar Thapa
Rohit Kumar Thapa
Contrast training (CT) involves pairing two biomechanically similar exercises with different loads and velocities within a set. While most studies paired dynamic resistance exercise with plyometric exercise within a contrast set, isometric exercise may also be a viable option as the primary exercise, specifically for individuals who are new to resistance training. Therefore, this study aimed to compare the effects of a 4-week isometric CT intervention on jump kinetics and kinematics and isometric strength of nonresistance-trained females. Using a within-subject research design, 12 female participants (age: 20.6 ± 1.3 years) participated in a control period followed by a 4-week isometric CT intervention. Precontrol, postcontrol, and postintervention period data were collected for countermovement jump, 10/5 repeated hop test for reactive strength index, isometric mid-thigh pull, and isometric squats. Statistical analyses revealed that compared with control condition, the isometric CT intervention significantly improved countermovement jump height ( p = .016–.048; g = 0.65–1.03), flight time ( p = .021; g = 0.70), absolute peak power ( p = .026; g = 0.73), relative peak power ( p = .025; g = 0.49), peak velocity ( p = .022; g = 0.84), 10/5 repeated hop test average reactive strength index ( p = .002; g = 1.56), peak reactive strength index ( p < .001; g = 1.64), average ground contact time ( p = .036; g = 0.21), average flight time ( p = .024; g = 1.24), average jump height ( p = .003; g = 1.24), and isometric squats peak force ( p = .025; g = 0.47). These findings indicate that pairing isometric and plyometric exercises in CT improves dynamic as well as isometric performance in nonresistance-trained female participants. Practically, isometric CT may be a useful entry-level training strategy for female participants to improve jump and isometric strength qualities.

24 September 2026 in Isokinetics and Exercise Science
Verified
Journal Article
Open access
Premraj SainiPremraj Saini
Premraj Saini
TBTim S Babu
Tim S Babu
ABAmritashish Bagchi
Amritashish Bagchi
Rohit Kumar ThapaRohit Kumar Thapa
Rohit Kumar Thapa
Background: Maximal effort conditioning activities, such as pushing isometric muscle action (PIMA) based push-ups, may acutely improve ballistic performance via the post-activation performance enhancement (PAPE) mechanism. The primary aim was to examine the effects of PIMA-based push-ups as a conditioning activity on medicine ball chest throw (MBCT) distance. The secondary aims were to determine the relationship between net peak force (NPF) produced during the PIMA push-up and MBCT distance, and assess the reliability of NPF measurement. Methods: Eighteen male athletes were randomly assigned to a control (general warm-up) or an experimental condition (general warm-up + PIMA-based push-ups [3 × 5 s with 1-min rest]) in a crossover design. MBCT performance was assessed after 1 and 3-min of recovery following each condition. Results: A significant main effect of condition ( p = 0.006) and time ( p < 0.001), and an interaction effect ( p = 0.042) were observed. MBCT distance was greater in the experimental condition at 3 min compared with all other conditions ( p ≤ 0.004), whereas no difference was observed at 1 min. A moderate correlation was found between NPF and MBCT distance at 1 min ( r = 0.477, p = 0.045), but not at 3 min ( p > 0.05). NPF showed excellent reliability (lower-bound intraclass correlation coefficient of 0.937, coefficient of variation of 9.7%). Conclusion: PIMA-based push-ups may be used as a conditioning activity to potentiate upper-body muscle power (specifically for MBCT), and both exercises may be paired as an upper-body contrast-training exercise during complex-contrast training sessions. However, long-term adaptations of such a combination in a complex-contrast training format require further investigation.

20 July 2026 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
Rohit Kumar ThapaRohit Kumar Thapa
Rohit Kumar Thapa
TBTIM S BABU
TIM S BABU
Premraj SainiPremraj Saini
Premraj Saini
ABAmritashish Bagchi
Amritashish Bagchi
Thapa, RK, Babu, TS, Saini, P, and Bagchi, A. Acute effects of complex-contrast exercise performed with two different intracontrast rest intervals on muscle activation, heart rate, and countermovement jump performance: a randomized crossover study. J Strength Cond Res XX(X): 000–000, 2026—This study compared the acute effects of complex-contrast training (CT) exercise sets performed with 2 different intracontrast rest intervals (ICRI; i.e., the rest period between resistance and ballistic exercise within CT) on muscle activation, heart rate, and countermovement jump (CMJ) performance. Eleven male subjects (age: 20.9 ± 1.6 years, height: 172.4 ± 6.2 cm, body mass: 66.2 ± 7.6 kg, relative back squat strength: 1.3 ± 0.2 kg·kg −1 ) completed 2 experimental CT sessions (with 85% of 1 repetition maximum back squat and CMJ as a contrast pair of exercise) using either 30-second or 4-minute ICRI in a randomized, crossover manner. Neuromuscular function was assessed pre- and post-CT using maximal voluntary isometric knee extension. Muscle activation (using surface electromyography) of rectus femoris, vastus lateralis, and vastus medialis was recorded during squats and CMJs across 3 CT sets and during the knee extension test. Countermovement jump kinetics and kinematics were assessed using force platforms. No differences between ICRI conditions were observed in peak force ( p = 0.319; ηp 2 = 0.05) or muscle activation ( p = 0.203–0.722; ηp 2 = 0.12–0.67) during the knee extension test, nor during squats or CMJs ( p = 0.060–0.773; ηp 2 = 0.02–0.50). Similarly, most CMJ kinetic and kinematic variables did not differ between conditions ( p = 0.287–0.992; ηp 2 < 0.01–0.28). However, CMJ peak relative force at set 3 ( p = 0.001, g = 1.26) and post-CT exercise heart rate ( p = 0.044, g = 0.67) differed between ICRI conditions, with the 4-minute ICRI maintaining peak relative force and eliciting a lower heart rate. These findings suggest that shorter ICRI does not exacerbate acute neuromuscular fatigue or impair CMJ performance but may increase cardiovascular strain. Therefore, shorter ICRI may be used to increase training session density when time is limited, while acknowledging the associated physiological stress.