Abdullahi Mas'ud

Dr. Abdullahi Mas'ud

Jubail Industrial College
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
SHSHAIKH MANIRUL HAQUE
SHAIKH MANIRUL HAQUE
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
Yunusa UmarYunusa Umar
Yunusa Umar
Abdullahi Mas'udAbdullahi Mas'ud
Abdullahi Mas'ud
Firdaus Muhammad SukkiFirdaus Muhammad Sukki
Firdaus Muhammad Sukki
NBNurul Aini Bani
Nurul Aini Bani
In this paper, the applications of thermoplastic, thermoset polymers, and a brief description of the functions of each subsystem are reviewed. The synthetic route and characteristics of polymeric materials are presented. The mechanical properties of polymers such as impact behavior, tensile test, bending test, and thermal properties like mold stress-relief distortion, generic thermal indices, relative thermal capability, and relative thermal index are mentioned. Furthermore, this paper covers the electrical behavior of polymers, mainly their dielectric strength. Different techniques for evaluating polymers’ suitability applied for electrical insulation are covered, such as partial discharge and high current arc resistance to ignition. The polymeric materials and processes used for manufacturing cables at different voltage ranges are described, and their applications to high voltage DC systems (HVDC) are discussed. The evolution and limitations of polymeric materials for electrical application and their advantages and future trends are mentioned. However, to reduce the high cost of filler networks and improve their technical properties, new techniques need to be developed. To overcome limitations associated with the accuracy of the techniques used for quantifying residual stresses in polymers, new techniques such as indentation are used with higher force at the stressed location.

1 November 2015 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
Abdullahi Mas'udAbdullahi Mas'ud
Abdullahi Mas'ud
AWAsan Vernyuy Wirba
Asan Vernyuy Wirba
Firdaus Muhammad SukkiFirdaus Muhammad Sukki
Firdaus Muhammad Sukki
IMIbrahim Abubakar Mas’uD
Ibrahim Abubakar Mas’uD
AMAbu Bakar Munir
Abu Bakar Munir
NYNorhidayah Md Yunus
Norhidayah Md Yunus

25 July 2016 in Energies
Verified
Journal Article
Open access
PDF file
Abdullahi Mas'udAbdullahi Mas'ud
Abdullahi Mas'ud
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
Firdaus Muhammad SukkiFirdaus Muhammad Sukki
Firdaus Muhammad Sukki
HIHazlee Azil Illias
Hazlee Azil Illias
AMAbu Bakar Munir
Abu Bakar Munir
In order to investigate how artificial neural networks (ANNs) have been applied for partial discharge (PD) pattern recognition, this paper reviews recent progress made on ANN development for PD classification by a literature survey. Contributions from several authors have been presented and discussed. High recognition rate has been recorded for several PD faults, but there are still many factors that hinder correct recognition of PD by the ANN, such as high-amplitude noise or wide spectral content typical from industrial environments, trial and error approaches in determining an optimum ANN, multiple PD sources acting simultaneously, lack of comprehensive and up to date databank of PD faults, and the appropriate selection of the characteristics that allow a correct recognition of the type of source which are currently being addressed by researchers. Several suggestions for improvement are proposed by the authors include: (1) determining the optimum weights in training the ANN; (2) using PD data captured over long stressing period in training the ANN; (3) ANN recognizing different PD degradation levels; (4) using the same resolution sizes of the PD patterns when training and testing the ANN with different PD dataset; (5) understanding the characteristics of multiple concurrent PD faults and effectively recognizing them; and (6) developing techniques in order to shorten the training time for the ANN as applied for PD recognition Finally, this paper critically assesses the suitability of ANNs for both online and offline PD detections outlining the advantages to the practitioners in the field. It is possible for the ANNs to determine the stage of degradation of the PD, thereby giving an indication of the seriousness of the fault.

1 April 2015 in Renewable Energy
Verified
Journal Article
Open access
AWAsan Vernyuy Wirba
Asan Vernyuy Wirba
Abdullahi Mas'udAbdullahi Mas'ud
Abdullahi Mas'ud
Firdaus Muhammad SukkiFirdaus Muhammad Sukki
Firdaus Muhammad Sukki
SASalman Ahmad
Salman Ahmad
RTRazman Mat Tahar
Razman Mat Tahar
EKErshadul Karim
Ershadul Karim
This paper aims at discussing the renewable energy potentials in delivering parts of the energy needs in Cameroon. The country has an enormous renewable energy potential. The lack of clear renewable energy policy in the mix is an issue that needs to be addressed urgently by the Cameroonian government policy makers. The absence of commitment and enthusiasm from the government is weakening the sector potentiality to be developed either by private sector investments and also foreign investors. Solar, wind and thermal energy plants are essential to meet the electrification of Cameroon

1 September 2016 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
Abdullahi Mas'udAbdullahi Mas'ud
Abdullahi Mas'ud
AWAsan Vernyuy Wirba
Asan Vernyuy Wirba
Firdaus Muhammad SukkiFirdaus Muhammad Sukki
Firdaus Muhammad Sukki
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
SASiti Hawa Abu-Bakar
Siti Hawa Abu-Bakar
NBNurul Aini Bani
Nurul Aini Bani
The harmful effects of carbon emissions and carbon dioxide caused by over dependence on oil is a global issue, which is currently being addressed by encouraging renewable energy (RE) resources contribution to the energy mix. Encouraging RE is important in order to solve the unsustainable nature of electricity generation especially in the sub-Saharan African countries. One of the REs that have vast potential especially in sub-Saharan Africa is the solar energy. This paper provides an overview of the solar photovoltaic (PV) developments in selected countries of sub-Saharan Africa – in terms of research, installed capacity, solar radiation level, RE policies and the percentage of solar PV in the future energy mix of these countries. Finally, this paper identified the barriers to RE deployment and proposed scaling-up solar PV as one of the solution in the development of energy mix in these countries

25 January 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
Abdullahi Mas'udAbdullahi Mas'ud
Abdullahi Mas'ud
A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.