Saad Al-Gahtani

Dr. Saad Al-Gahtani

Electrical engineering Department, King Khalid University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
Ragab Abdelaziz El-SehiemyRagab Abdelaziz El-Sehiemy
Ragab Abdelaziz El-Sehiemy
Abdullah Mohammed ShaheenAbdullah Mohammed Shaheen
Abdullah Mohammed Shaheen
AGAhmed Ginidi
Ahmed Ginidi
SASaad Al-Gahtani
Saad Al-Gahtani
A major problem in power systems is achieving a match between the load demand and generation demand, where security, dependability, and quality are critical factors that need to be provided to power producers. This paper proposes a proportional–integral–derivative (PID) controller that is optimally designed using a novel artificial rabbits algorithm (ARA) for load frequency control (LFC) in multi-area power systems (MAPSs) of two-area non-reheat thermal systems. The PID controller incorporates a filter with such a derivative coefficient to reduce the effects of the accompanied noise. In this regard, single objective function is assessed based on time-domain simulation to minimize the integral time-multiplied absolute error (ITAE). The proposed ARA adjusts the PID settings to their best potential considering three dissimilar test cases with different sets of disturbances, and the results from the designed PID controller based on the ARA are compared with various published techniques, including particle swarm optimization (PSO), differential evolution (DE), JAYA optimizer, and self-adaptive multi-population elitist (SAMPE) JAYA. The comparisons show that the PID controller’s design, which is based on the ARA, handles the load frequency regulation in MAPSs for the ITAE minimizations with significant effectiveness and success where the statistical analysis confirms its superiority. Considering the load change in area 1, the proposed ARA can acquire significant percentage improvements in the ITAE values of 1.949%, 3.455%, 2.077% and 1.949%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA. Considering the load change in area 2, the proposed ARA can acquire significant percentage improvements in the ITAE values of 7.587%, 8.038%, 3.322% and 2.066%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA. Considering simultaneous load changes in areas 1 and 2, the proposed ARA can acquire significant improvements in the ITAE values of 60.89%, 38.13%, 55.29% and 17.97%, respectively, with regard to PSO, DE, JAYA and SAMPE-JAYA.

21 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
SASaad Al-Gahtani
Saad Al-Gahtani
Recent statistics indicate that as of 2023, the global renewable energy capacity has reached new heights, with Saudi Arabia significantly contributing to this growth through its strategic initiatives. The kingdom is particularly focusing on harnessing solar power, given its abundant sunlight, and is also exploring wind energy, leveraging its vast desert landscapes. These efforts are part of Saudi Arabia’s broader strategy to become a global leader in renewable energy. This paper provides a detailed exploration of Saudi Arabia’s ambitious journey from a fossil-fuel-dominated energy sector to a more sustainable, renewable-energy-driven future. Anchored in the broader context of global energy trends, the study emphasizes the critical shift toward renewable resources, with a particular focus on Saudi Arabia’s unique position in this global movement. Key to this transition is Saudi Arabia’s Vision 2030, a strategic framework that guides the country’s renewable energy policies and initiatives. A comprehensive review of these policies, including other governmental and international collaborations that support renewable energy development, is offered. The current state of renewable energy in Saudi Arabia is assessed, including an overview of existing projects and production statistics. The paper also explores emerging technologies such as energy storage systems and smart grid solutions, emphasizing their role in Saudi Arabia’s energy transition. An impact assessment is conducted to understand the environmental, economic, and social effects of this energy shift. The paper also includes a comparative analysis of other countries’ renewable energy transitions, extracting lessons and best practices applicable to the Saudi context. Strategic recommendations and reflections on Saudi Arabia’s future role in the global energy landscape are provided for stakeholders in energy policy, environmental planning, and sustainable development.

17 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
Abdullah Mohammed ShaheenAbdullah Mohammed Shaheen
Abdullah Mohammed Shaheen
Ragab Abdelaziz El-SehiemyRagab Abdelaziz El-Sehiemy
Ragab Abdelaziz El-Sehiemy
AGAhmed Ginidi
Ahmed Ginidi
AEAbdallah M. Elsayed
Abdallah M. Elsayed
SASaad Al-Gahtani
Saad Al-Gahtani
Incorporating photovoltaic (PV) inverters in power distribution systems via static synchronous compensators (PV-STATCOM) during the nighttime has lately been described as a solution to improve network performance. Hunter prey optimization (HPO) is introduced in this study for efficient PV-STATCOM device allocation in distribution systems. HPO generates numerous scenarios for how animals could act when hunting, some of which have been expanded into stochastic optimization. The PV-STATCOM device allocation issue in distribution networks is structured to simultaneously minimize the electrical energy losses and improve the voltage profile while accounting for variable 24 h loadings. The impacts of varying the number of installed PV-STATCOM devices are investigated in distribution systems. It is tested on two IEEE 33-node and 69-node distribution networks. The effectiveness of the proposed HPO is demonstrated in comparison to the differential evolution (DE) algorithm, particle swarm optimization (PSO), artificial rabbits algorithm (ARA), and golden search optimizer (GSO). The simulation results demonstrate the efficiency of the proposed HPO in adequately allocating the PV-STATCOM devices in distribution systems. For the IEEE 33-node distribution network, the energy losses are considerably decreased by 57.77%, and the voltages variance sum is significantly reduced by 42.84%. The energy losses in the IEEE 69-node distribution network decreased by 57.89%, while voltage variations are reduced by 44.69%. Additionally, the suggested HPO is highly consistent than the DE, PSO, ARA, and GSO. Furthermore, throughout the day, the voltage profile at all distribution nodes surpasses the minimum requirement of 95%.

15 February 2022 in IEEE Access
Verified
Journal Article
Open access
SASaad Al-Gahtani
Saad Al-Gahtani
ABAbdulwasa B. Barnawi
Abdulwasa B. Barnawi
HAHaitham Zaki Azazi
Haitham Zaki Azazi
SIShaik Mohammad Irshad
Shaik Mohammad Irshad
JBJAVED KHAN BHUTTO
JAVED KHAN BHUTTO
ESElbarbary Z. M. Salem
Elbarbary Z. M. Salem
Nowadays, power quality under the excessive implementation of power electronics devices is quite challenging issue. The compensation of non-sinusoidal; reactive and harmonic; components is the main role for power quality devices which highly depend on the robustness of the control system. Some common control systems are implemented using Synchronous Stationary Frame (DQ) theory. This paper proposes a new version of DQ control technique to control dynamic voltage restorer under severe transient voltage conditions. The power system network with the new DQ control technique is studied and analyzed under different scenarios to compensate for severe balanced and unbalanced voltage sags and swells. This new scheme is based on extraction of positive sequence components to implement the control algorithm. A mathematical model of the dynamic voltage restorer (DVR), hysteresis voltage control, converter controller model, new DQ scheme with complete system equations are carried out and verified using Simulink / MATLAB. The proposed system is validated experimentally using DSpace 1104 based laboratory system. The obtained results of the proposed compensation algorithm are compared with the results obtained from the traditional DQ method. Simulation and experimental results are correlated and show effectiveness of the proposed DQ control scheme.

23 June 2022 in IEEE Access
Verified
Journal Article
Open access
SASaad Al-Gahtani
Saad Al-Gahtani
ESElbarbary Z. M. Salem
Elbarbary Z. M. Salem
SIShaik Mohammad Irshad
Shaik Mohammad Irshad
HAHaitham Zaki Azazi
Haitham Zaki Azazi
In today’s power system, power quality is a critical topic having several impacts on customers and utilities. In the current electric power system, the integration of renewable energy sources, smart grid technologies, and significant usage of power electronics equipment has generated a slew of issues. The sensitive equipment might be damaged by harmonics, voltage sag, and swell. These devices are vulnerable to Interference with other elements of the system resulting in input voltage changes. As a result, in the contemporary period, Power quality is becoming more important as the number of sensitive and costly electronic devices grows. To overcome the challenges of non-standard voltage, the Dynamic Voltage restorer (DVR) device has been extensively utilized to keep the load voltage stable. To have a dynamic and fast response of the DVR a modified instantaneous reactive power (PQ) theory is proposed to control DVR under extreme transient voltage circumstances. The proposed technique is based on the extraction of the positive sequence component of grid voltage and the negative sequence component of load current for generating a voltage reference signal. The power system network with the proposed PQ control scheme is investigated and assessed under various scenarios to compensate for severe balanced, unbalanced (voltage sags and swells), and load change. MATLAB/Simulink is used to verify the mathematical models of the conventional PQ and proposed PQ control system for DVR. The complete system is implemented experimentally using a dSPACE 1104 based laboratory system to validate the presented control scheme. The simulation and experimental results are correlated, demonstrating the efficacy of the suggested modified PQ control technique.

7 January 2025 in IEEE Access
Verified
Journal Article
Open access
RARahmat Aazami
Rahmat Aazami
MMMohammad Moradi
Mohammad Moradi
Mohammadamin ShirkhaniMohammadamin Shirkhani
Mohammadamin Shirkhani
AHAMBE HARRISON
AMBE HARRISON
SASaad Al-Gahtani
Saad Al-Gahtani
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
Energy consumption and efficiency, along with occupant well-being, are key global challenges across various sectors, especially in the industrial and residential domains. Building automation, which exists at multiple levels, plays a crucial role in addressing these challenges. This study evaluates three distinct levels of automation—scheduling-based, sensor-based, and IoT-enabled control—allowing a clear comparison of each system's effectiveness in managing energy consumption and enhancing occupant comfort. This approach simplifies the decision-making process by identifying the level of control that optimally balances energy efficiency with thermal comfort requirements, particularly in residential contexts. The integration of the Internet of Things (IoT) into building control systems, a hallmark of the Fourth Industrial Revolution, further enhances these capabilities. Building automation and control systems can be categorized into standard and advanced systems. Conventional control methods fall short of meeting the increasingly complex demands of smart buildings. However, leveraging IoT in smart building design can significantly enhance quality of life by making smart systems more efficient, optimizing resource allocation, and improving management capabilities and services. A key application of IoT in smart buildings is the efficient management of HVAC (heating, ventilation, and air conditioning) systems, which enhances occupant comfort while reducing energy consumption. This paper presents a simulation of a residential building in Ilam, where energy consumption and occupant comfort levels are analyzed across various scenarios. The study identifies optimal conditions for both energy efficiency and resident well-being. By evaluating a residential building, this research compares energy consumption and comfort across basic scheduling, sensor-based control, and advanced IoT-enabled automation levels. Optimal configurations that improve energy savings and occupant comfort are identified, highlighting the effectiveness of IoT integration in HVAC management. The results demonstrate that advanced automation, particularly IoT-based control, offers significant advantages for energy management and comfort optimization in residential buildings.