Savita Kumari

Dr. Savita Kumari

Biosciences and Bioengineering, Indian Institute of Technology, Bombay, Mumbai, India
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
VAVishnuram Abhinav
Vishnuram Abhinav
PBPrithvi Basu
Prithvi Basu
SVShikha Supriya Verma
Shikha Supriya Verma
JVJyoti Verma
Jyoti Verma
ADAtanu Das
Atanu Das
VKVibhor Kumar
Vibhor Kumar
Wearable and implantable BioMEMSs (biomedical microelectromechanical systems) have transformed modern healthcare by enabling continuous, personalized, and minimally invasive monitoring, diagnostics, and therapy. Wearable BioMEMSs have advanced rapidly, encompassing a diverse range of biosensors, bioelectronic systems, drug delivery platforms, and motion tracking technologies. These devices enable non-invasive, real-time monitoring of biochemical, electrophysiological, and biomechanical signals, offering personalized and proactive healthcare solutions. In parallel, implantable BioMEMS have significantly enhanced long-term diagnostics, targeted drug delivery, and neurostimulation. From continuous glucose and intraocular pressure monitoring to programmable drug delivery and bioelectric implants for neuromodulation, these devices are improving precision treatment by continuous monitoring and localized therapy. This review explores the materials and technologies driving advancements in wearable and implantable BioMEMSs, focusing on their impact on chronic disease management, cardiology, respiratory care, and glaucoma treatment. We also highlight their integration with artificial intelligence (AI) and the Internet of Things (IoT), paving the way for smarter, data-driven healthcare solutions. Despite their potential, BioMEMSs face challenges such as regulatory complexities, global standardization, and societal determinants. Looking ahead, we explore emerging directions like multifunctional systems, biodegradable power sources, and next-generation point-of-care diagnostics. Collectively, these advancements position BioMEMS as pivotal enablers of future patient-centric healthcare systems.

11 August 2023 in Soft Matter
Verified
Journal Article
Closed access
PDF file
RRRamiz Raza
Ramiz Raza
JGJijo Easo George
Jijo Easo George
SKSavita Kumari
Savita Kumari
MMMithun K. Mitra
Mithun K. Mitra
DPDebjani Paul
Debjani Paul
We developed a two-layer microfluidic device to study the motility dynamics of E. coli. We show that both confinement and chemoattractant lead to anomalous diffusion, with power-law distributed run lengths and suppression of large-angle tumbles.

14 June 2024 in Cell Reports Physical Science
Verified
Journal Article
Open access
SKSavita Kumari
Savita Kumari
NMNinad Mehendale
Ninad Mehendale
TRTanusri Roy
Tanusri Roy
SSShamik Sen
Shamik Sen
DMDhrubaditya Mitra
Dhrubaditya Mitra
DPDebjani Paul
Debjani Paul

20 April 2025 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JGJijo Easo George
Jijo Easo George
JMJenil Mange
Jenil Mange
SRShomdutta Roy
Shomdutta Roy
SKSavita Kumari
Savita Kumari
RRRamiz Raza
Ramiz Raza
DPDebjani Paul
Debjani Paul

19 July 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
SKSavita Kumari
Savita Kumari
NMNinad Mehendale
Ninad Mehendale
TRTanusri Roy
Tanusri Roy
SSShamik Sen
Shamik Sen
DMDhrubaditya Mitra
Dhrubaditya Mitra
DPDebjani Paul
Debjani Paul
SUMMARY: We report a high-throughput microfluidic device to determine the Young’s modulus of single red blood cells (RBCs). Our device consists of a single channel opening into a funnel, with a semi-circular obstacle placed at the mouth of the funnel. As a RBC passes the obstacle, it deflects from its original path. Using populations of artificially-stiffened RBCs, we show that the stiffer RBCs deflect more compared to the healthy RBCs. We then generate a calibration curve that maps each RBC trajectory to its Young’s modulus obtained using an atomic force microscope. Finally, we sort a mixed population of RBCs based on their deformability alone. Our device could potentially be further miniaturized to sort and obtain the elastic constants of nanoscale objects, such exosomes, whose shape change is difficult to monitor by optical microscopy.

13 March 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
JGJijo Easo George
Jijo Easo George
RMRiddha Manna
Riddha Manna
SRShomdutta Roy
Shomdutta Roy
SKSavita Kumari
Savita Kumari
DPDebjani Paul
Debjani Paul
Step emulsification (SE), which generates droplets by a sharp change in confinement, has emerged as a potential alternative to flow-focusing technology. Water/dispersed phase is continuously pumped through a shallow inlet channel into a deep chamber pre-filled with the oil/continuous phase. The need for one or more pumps to maintain a continuous flow for droplet generation, and the consequent use of high sample volumes, limit this technique to research labs. Here, we report a pumpfree SE technique for rapid and high-throughput generation of monodisperse hydrogel (agarose) beads using <40 µ l sample volume. Instead of using syringe pumps, we sequentially pipetted oil and liquid agarose into a microfluidic SE device to generate between 20000 and 80000 agarose beads in ∼ 2 min. We also demonstrated the encapsulation of loop-mediated isothermal amplification mixture inside these beads at the time of their formation. Finally, using these beads as reaction chambers, we amplified nucleic acids from P. falciparum and SARS-CoV-2 inside them. The pump-free operation, tiny sample volume, and high-throughput generation of droplets by SE make our technique suitable for point-of-care diagnostics.