Thomas Mayer

Mr. Thomas Mayer

Monitoring & Exploration Technologies, Helmholtz Centre for Environmental Research, Leipzig, Saxony, Germany
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2011 in Applied Spectroscopy Reviews
Verified
Journal Article
Closed access
HBHelko Borsdorf
Helko Borsdorf
TMThomas Mayer
Thomas Mayer
Mashaalah ZarejousheghaniMashaalah Zarejousheghani
Mashaalah Zarejousheghani
GEGary A. Eiceman
Gary A. Eiceman
The general principles and technical implementations of traditional time-of-flight ion mobility spectrometers and analyzers with field-dependent mobilities were reviewed in our last article in this journal. Recent advances in instrumentation and new applications since 2006 are highlighted in this review. In addition to traditional applications as military chemical-agent detectors, ion mobility techniques have become popular for different purposes. Though ion mobility spectrometry was solely used as vapor sensor in the past decades, further developments in ionization techniques (especially electrospray ionization) now permit its routine use for the analysis of liquid samples. The coupling of ion mobility spectrometry with selective sample preparation techniques such as molecular-imprinted polymers, coupling with chromatographic techniques, the use of dopants, and application of selective ionization sources has led to an expanded number of applications in industrial and environmental analysis with complex sample matrices due to an improved selectivity in comparison with traditional stand-alone spectrometers. Furthermore, new developments in hyphenated techniques, especially ion mobility–mass spectrometry couplings, has resulted in an increased number of new applications for the analysis of biomolecules and pharmaceutical samples and in clinical diagnostics.

9 April 2014 in Analytical Chemistry
Verified
Journal Article
Closed access
TMThomas Mayer
Thomas Mayer
HBHelko Borsdorf
Helko Borsdorf

1 October 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
HBHelko Borsdorf
Helko Borsdorf
PFPetra Fiedler
Petra Fiedler
TMThomas Mayer
Thomas Mayer

30 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TGTobias Goblirsh
Tobias Goblirsh
TMThomas Mayer
Thomas Mayer
SPStefanie Penzel
Stefanie Penzel
MRMathias Rudolph
Mathias Rudolph
HBHelko Borsdorf
Helko Borsdorf
Optical methods such as ultraviolet/visible (UV/Vis) and fluorescence spectroscopy are well-established analytical techniques for in situ water quality monitoring. A broad range of bio-logical and chemical contaminants in different concentration ranges can be detected using these methods. The availability of results in real time allows a quick response to water quality changes. The measuring devices are configured as portable multi-parameter probes. However, their specification and data processing typically cannot be changed by users, or only with difficulties. Therefore, we developed a submersible sensor probe, which combines UV/Vis and fluorescence spectroscopy together with a flexible data processing platform. Due to its modular design in the hardware and software, the sensing system can be modified to the specific application. The dimension of the waterproof enclosure with a diameter of 100 mm permits also its application in groundwater monitoring wells. As a light source for fluorescence spectroscopy, we constructed an LED array that can be equipped with four different LEDs. A miniaturized deuterium–tungsten light source (200–1100 nm) was used for UV/Vis spectroscopy. A miniaturized spectrometer with a spectral range between 225 and 1000 nm permits the detection of complete spectra for both methods.

26 August 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
HBHelko Borsdorf
Helko Borsdorf
MBMaja Bentele
Maja Bentele
MMMichael Müller
Michael Müller
CRCorinna Rebmann
Corinna Rebmann
TMThomas Mayer
Thomas Mayer
Ambient atmospheric concentrations of isoprene and monoterpenes were measured at two forest sites, one deciduous and one coniferous, over the year 2022. Both sites in a regional area were sampled monthly between April and September. The samples were taken using sorbent tubes and analyzed with thermal desorption–gas chromatography–mass spectrometry. The highest concentrations were determined in August at both sites. While isoprene is the most abundant compound at the deciduous forest with an average concentration of 5.59 µg m−3 in August, α-pinene and β-pinene dominate throughout the year at the coniferous forest with the highest concentrations also in August (3.44 µg m−3 and 1.51 µg m−3). Because other monoterpenes (camphene, sabinene, 3-carene, p-cymene and limonene) are also emitted in significant amounts, the total concentration measured in the coniferous forest is higher (7.96 µg m−3 in August) in comparison to the deciduous forest (6.08 µg m−3). Regarding the detected monoterpenes in the deciduous forest, sabinene is the dominant monoterpene in addition to α-pinene and is sometimes present in higher (July) or equal (August) concentrations. The seasonal and diurnal concentrations of all monoterpenes correlate very well with each other at both sites. An exception is sabinene with a diurnal concentration profile similar to isoprene.

1 November 2012 in Talanta
Verified
Journal Article
Closed access
HBHelko Borsdorf
Helko Borsdorf
TMThomas Mayer
Thomas Mayer