Tomas Kačinskas

Mr. Tomas Kačinskas

Kaunas University of Technology, Kaunas, Kauno Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Journal of Manufacturing Processes
Verified
Journal Article
Closed access
Regita BendikieneRegita Bendikiene
Regita Bendikiene
SBSaulius Baskutis
Saulius Baskutis
JBJolanta Baskutiene
Jolanta Baskutiene
Antanas CiuplysAntanas Ciuplys
Antanas Ciuplys
Tomas KačinskasTomas Kačinskas
Tomas Kačinskas

1 June 2024 in Materials
Verified
Journal Article
Open access
PDF file
Tomas KačinskasTomas Kačinskas
Tomas Kačinskas
Saulius BaskutisSaulius Baskutis
Saulius Baskutis
Jolanta BaskutieneJolanta Baskutiene
Jolanta Baskutiene
LKLina Kavaliauskiene
Lina Kavaliauskiene
This article presents the research results of depositing anti-friction coatings (Babbitt) using three different casting methods: static casting, flame soldering, and clad welding. Babbitt alloy coatings deposited with different casting methods are discussed and explained in terms of changes in the coating properties, such as the microstructure, hardness, strength, and chemical composition. The results showed significant differences in the aforementioned properties, depending on the chosen coating deposition method. The results of the tests confirmed the importance of using shielding gas during deposition to ensure the chemical composition of the coating. The analysis revealed that decreases in the amounts of antimony and copper in the Babbitt coating compared with the initial concentrations were influenced by selective evaporation, oxidation, and the coating process parameters associated with different coating methods. To maintain the desired balance of mechanical properties in Babbitt coatings, it is important to control the antimony and copper contents. Clad welding deposition using a non-consumable tungsten electrode and argon shielding gas achieved a chemically stable coating quite close to the initial chemical composition of the Babbitt alloy.

13 August 2025 in Inventions
Verified
Journal Article
Open access
PDF file
Tomas KačinskasTomas Kačinskas
Tomas Kačinskas
Saulius BaskutisSaulius Baskutis
Saulius Baskutis
This study introduces a MATrix LABoratory (MATLAB, version R2024b, update 1 (24.2.0.2740171))-based automated system for the detection and measurement of indication areas in coated surfaces, enhancing the accuracy and efficiency of quality control processes in metal, polymeric and thermoplastic coatings. The developed code identifies various indication characteristics in the image and provides numerical results, assesses the size and quantity of indications and evaluates conformity to ISO standards. A comprehensive testing method, involving non-destructive penetrant testing (PT) and radiographic testing (RT), allowed for an in-depth analysis of surface and internal porosity across different coating methods, including aluminum-, copper-, polytetrafluoroethylene (PTFE)- and polyether ether ketone (PEEK)-based materials. Initial findings had a major impact on indicating a non-homogeneous surface of obtained coatings, manufactured using different technologies and materials. Whereas researchers using non-destructive testing (NDT) methods typically rely on visual inspection and manual counting, the system under study automates this process. Each sample image is loaded into MATLAB and analyzed using the Image Processing Tool, Computer Vision Toolbox, Statistics and Machine Learning Toolbox. The custom code performs essential tasks such as image conversion, filtering, boundary detection, layering operations and calculations. These processes are integral to rendering images with developed indications according to NDT method requirements, providing a detailed visual and numerical representation of the analysis. RT also validated the observations made through surface indication detection, revealing either the absence of hidden defects or, conversely, internal porosity correlating with surface conditions. Matrix and graphical representations were used to facilitate the comparison of test results, highlighting more advanced methods and materials as the superior choice for achieving optimal mechanical and structural integrity. This research contributes to addressing challenges in surface quality assurance, advancing digital transformation in inspection processes and exploring more advanced alternatives to traditional coating technologies and materials.

5 November 2026 in Materials
Verified
Journal Article
Open access
PDF file
Saulius BaskutisSaulius Baskutis
Saulius Baskutis
YKYaroslav Ярослав Kusyi
Yaroslav Ярослав Kusyi
LKLina Kavaliauskiene
Lina Kavaliauskiene
Jolanta BaskutieneJolanta Baskutiene
Jolanta Baskutiene
Tomas KačinskasTomas Kačinskas
Tomas Kačinskas
OOOleh Onysko
Oleh Onysko
This study evaluates a material homogeneity criterion (MHC)-based workflow for the spatial characterization of macrohardness variability in tungsten inert gas (TIG) welded AISI 304 stainless-steel joints produced using 308LSi filler metal. Five welded specimens produced under different welding conditions were first evaluated by transverse tensile testing. Two specimens representing contrasting mechanical responses were subsequently selected for identical spatial macrohardness mapping: Specimen 1 exhibited the lowest ultimate tensile strength (610 MPa), 24% elongation, and fracture through the weld region, whereas Specimen 3 exhibited the highest ultimate tensile strength (684 MPa), 41% elongation, and fracture in the base material. For each specimen, 1000 Rockwell macrohardness (HRBW) measurements were obtained along twenty transverse measurement lines spanning the base material (BM), heat-affected zone (HAZ), and fusion zone (FZ). Mean hardness ranges were comparatively similar for Specimens 1 and 3 (92.04–95.70 and 92.00–95.50 HRBW, respectively). Meanwhile, the coefficient of variation (CV) and Weibull homogeneity coefficient (WHC) provided greater discrimination between the two joints. Specimen 1 exhibited CV values of 0.534–1.433% and WHC values of 81.20–216.95, whereas Specimen 3 exhibited CV values of 0.542–1.076% and WHC values of 107.87–214.12. The largest between-specimen difference was observed within the HAZ, where Specimen 1 exhibited substantially greater macrohardness dispersion than Specimen 3. These results show that statistical treatment of repeated macrohardness measurements can reveal spatial differences between welded joints that are less evident from mean-hardness profiles alone. The comparison does not establish a general predictive relationship between hardness dispersion and tensile performance but provides experimental evidence supporting the discriminatory value of spatial CV and WHC mapping for the two investigated contrasting cases. Optical metallography provides complementary qualitative microstructural characterization, while quantitative relationships between microstructural parameters and macrohardness dispersion remain outside the scope of the present study.

25 August 2026 in Coatings
Verified
Journal Article
Open access
PDF file
Tomas KačinskasTomas Kačinskas
Tomas Kačinskas
Saulius BaskutisSaulius Baskutis
Saulius Baskutis
VGValdas Grigaliūnas
Valdas Grigaliūnas
Bearing-grade PEEK composites are intended to improve sliding performance, but filler addition does not necessarily reduce friction. This study compared the dry sliding tribological behaviour of neat PEEK and hybrid PEEK containing PTFE, graphite, and carbon fibre against 42CrMo4+QT steel. Ring-on-block tests were performed at nominal PV values of 0.3–3.2 MPa·m/s, contact pressures of 0.87–5.82 MPa, and sliding velocities of 0.26–0.55 m/s. Each material–condition combination was tested using three independent specimens. Coefficient of friction was calculated from simultaneously measured tangential and normal forces, and subsurface temperature was recorded continuously. Initial and post-test surfaces were examined using optical and extended depth-of-field microscopy. Group mean COF values ranged from 0.052 to 0.123. Hybrid PEEK exhibited a higher numerical mean COF than neat PEEK in all six operating conditions, with relative differences of approximately 1.53–8.36%. Two-factor ANOVA estimated an overall hybrid-minus-neat difference of +0.003388 COF units (95% CI 0.001279–0.005496; p = 0.0029), whereas none of the six condition-specific neat–hybrid comparisons was significant after Holm correction. Initial temperature, maximum temperature, and baseline-normalised temperature rise were reported for every specimen and treated descriptively. Both materials reached stable sliding states without seizure or uncontrolled thermal escalation. Post-test EDF observations showed a denser pattern of fine grooves on neat PEEK, whereas hybrid PEEK exhibited comparatively smoother intervening regions interrupted by fewer but locally deeper features. Mass changes remained close to the capability of the applied balance and did not permit quantitative wear-rate comparison. The results show that the investigated hybrid formulation did not provide a dry-friction reduction advantage over neat PEEK under the tested conditions.