JORGE ALBERTO UC-MARTIN

JORGE ALBERTO UC-MARTIN

Facultad Ingeniería, UNAM, Mexico City, Ciudad de México, Mexico
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2020
Verified
Conference Paper
Closed access
JORGE ALBERTO UC-MARTINJORGE ALBERTO UC-MARTIN
JORGE ALBERTO UC-MARTIN
AGAsur Guadarrama-Santana
Asur Guadarrama-Santana
AGAugusto Garcia-Valenzuela
Augusto Garcia-Valenzuela
We report a measurement methodology to sense electrically the presence of nanoparticles in suspensions in droplets and assess their type and density. The nanoparticle suspensions used in this work were solvent-based. A small amount of the suspensions was placed on the sensitive surface of an interdigitated capacitance sensor and left to evaporate at ambient temperature while the capacitance signal was registered. Our sensor has a driving and a sensing interdigitated spiral electrode array and the output signal is proportional to the impedance difference between similar sensors, reference and sensing. They were designed and fabricated over a glass-substrate. A low noise measurement system based on a Lock-in Amplifier monitored continuously in time the evaporation process of nanoparticle suspension droplet by registering variations of the imaginary component of the differential current. The results show that it is possible to infer the presence of nanoparticles in suspension and distinguish, at least between two types of nanoparticles, at very low volume concentrations.

8 March 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JORGE ALBERTO UC-MARTINJORGE ALBERTO UC-MARTIN
JORGE ALBERTO UC-MARTIN
AOAlejandro Ortega-Aguilar
Alejandro Ortega-Aguilar
AGAsur Guadarrama-Santana
Asur Guadarrama-Santana
AGAugusto García-Valenzuela
Augusto García-Valenzuela
This article presents a variable-capacitance sensor for sessile droplet evaporation rate and lifetime measurements. The sensor consists of a plane-parallel-electrode capacitor with a commercial glass substrate inserted within. The glass substrate has a concave cavity at its center to deposit a liquid droplet for its measurement. An air gap is left between the substrate and the upper electrode to allow for the droplet’s evaporation. The main advantage of this configuration is that it fixes the position and geometric shape of the droplet. An analytical model based on the local-height approximation is developed to calculate the capacitance of the device, with and without a liquid droplet. Its validity is initially tested comparing with finite element calculations. Then, using the analytical model we simulate the capacitance signal during the evaporation of a sessile droplet and compare it with experimental results finding very good correspondence. The differential capacitance signal follows closely the volumetric changes of the droplet. The evaporation kinetics and lifetime of 3.5 ± 0.1 microliter droplets of ethanol and methanol mixtures are presented. We also show that the evaporation kinetics and lifetime of a droplet can be used to reveal the presence of a surfactant at very low concentrations. The results presented demonstrate the ability of the sensor to monitor the evaporating droplet from start to end.

10 January 2025 in IEEE Sensors Letters
Verified
Journal Article
Closed access
BABryan E Alvarez-Serna
Bryan E Alvarez-Serna
DADaniel A. Arcos-Santiago
Daniel A. Arcos-Santiago
JORGE ALBERTO UC-MARTINJORGE ALBERTO UC-MARTIN
JORGE ALBERTO UC-MARTIN
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
This letter introduces a self-calibrating electrochemical sensor for water acetaminophen detection. The sensor is built upon a graphite pencil lead electrode modified with a molecularly imprinted polymer to ensure selectivity. Moreover, using a sparse identification scheme, the sensor is equipped with a dynamic calibration algorithm to increase the sensor accuracy in time-dependent measurements. The sensor performance was evaluated under static and dynamic conditions using ACT solutions prepared in tap water as the matrix. As a result, the sensor achieved a detection limit of 9.3 mg/L, proving to be a viable alternative for quantifying emerging concerns in water. Finally, we show how simple but robust sensor models could enhance the performance of online measurements

6 August 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
JORGE ALBERTO UC-MARTINJORGE ALBERTO UC-MARTIN
JORGE ALBERTO UC-MARTIN
ACAlejandro Cortés-Díaz-Sandi
Alejandro Cortés-Díaz-Sandi
Ilianny Castellón PérezIlianny Castellón Pérez
Ilianny Castellón Pérez
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
Electrical bioimpedance (BioZ) has emerged as a promising technique for the non-invasive monitoring of physiological parameters, owing to its ability to map functional activity into electrical changes. Particularly, impedance plethysmography (IPG) is used to track blood volume changes associated with cardiac activity. However, developing flexible, low-cost devices with enough sensitivity to serve as high-precision for IPGs remains an open challenge. In this work, we introduce laser-induced graphene (LIG) electrodes as an attractive alternative for IPG measurements. The electrodes were fabricated by generating LIG on a polyimide substrate using a 405 nm laser diode and were subsequently characterized morphologically, structurally, and electrically to produce a wrist-worn cardiac impedance sensor (WCIS). The design of the WCIS is based on interdigitated electrodes to detect IPG variations at the radial artery, from which the heart rate is estimated. We show experimental results on IPG signal analysis and its validation against electrocardiogram (ECG) signals as the gold standard. As a result, a mean absolute error (MAE) of 1.7 bpm, a root mean square error (RMSE) of 2.1 bpm, and a limit of agreement of approximately ±6 bpm were obtained. These outcomes demonstrate the feasibility of the WCIS as a promising, low-cost alternative for continuous, non-invasive cardiovascular monitoring in portable devices, based on the IPG principle.

12 April 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
JORGE ALBERTO UC-MARTINJORGE ALBERTO UC-MARTIN
JORGE ALBERTO UC-MARTIN
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
Sodium dodecyl sulfate (SDS) is an anionic surfactant and is listed as an emerging contaminant due to its excessive use in industrial settings and homes. Therefore, there is a need to develop new detection methods for SDS particles that provide easy-to-interpret responses at reasonable times, to complement the established analytical methods. In this letter, we introduce a variable-capacitance measurement system (VCMS) and its associated methodology for detecting the presence of SDS particles in pure liquids. Using a microliter liquid sample, the system records in terms of capacitance, the effects due to the presence of SDS on the evaporation kinetics and lifetime of a sample in vaporization. This unexplored electrical measurement perspective provides simple traces as a function of the volumetric changes of the droplet. The high resolution and sensitivity of the system, allow it to detect the presence of SDS particles in the order of 1 mgL $^{-1}$ , complying with regulatory requirements. Finally, the proposed VCMS can provide information in a relatively short time and has potentiality in quality control applications.

1 May 2025 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
JORGE ALBERTO UC-MARTINJORGE ALBERTO UC-MARTIN
JORGE ALBERTO UC-MARTIN
AGAsur Guadarrama-Santana
Asur Guadarrama-Santana
RRRoberto G. Ramírez-Chavarría
Roberto G. Ramírez-Chavarría
We present a prototype of an unmodified carbon paste electrode sensor (SCPE) with the potential to distinguish electrolyte conductivity changes. Electrodes are placed in a syringe tube that acts as a holder in a coplanar configuration. This design allows for a portable sensor that fits into different electrolyte-holding containers. As proof of concept, a potassium chloride (KCl) suspension was used in a concentration range of 0 to 35 mgL−1. The operating frequency of the prototype was determined by impedance spectroscopy (IS) analysis, where the sensor presented good sensitivity and the best results. The morphological characterization of the transducer surface, performed by field emission scanning electron microscopy (FeSEM), shows a typical carbon paste surface. Finally, this simple, portable, and reusable design, combined with its low cost, takes advantage of the properties of graphite, provides information in a relatively short time, and has potential in quality control applications.