In this paper, we present an attractive EGFET-based pH sensor that integrates a n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) as the transducer and low-cost electrochemical screen-printed electrodes (SPE) as the sensitive element. Our sensor is based on a metallic silver/silver-chloride (Ag/AgCl) reference electrode and an indium-tin-oxide (ITO) sensitive electrode, operating in the pH range of 2 to 9. Results show that the proposed sensor can measure pH with acceptable sensitivity and resolution.
The development of sensitive and affordable testing devices for infectious diseases is essential to preserve public health, especially in pandemic scenarios. In this work, we have developed an attractive analytical method to monitor products of genetic amplification, particularly the loop-mediated isothermal amplification reaction (RT-LAMP). The method is based on electrochemical impedance measurements and the distribution of relaxation times model, to provide the so-called time-constant-domain spectroscopy (TCDS). The proposed method is tested for the SARS-CoV-2 genome, since it has been of worldwide interest due to the COVID-19 pandemic. Particularly, once the method is calibrated, its performance is demonstrated using real wastewater samples. Moreover, we propose a simple classification algorithm based on TCDS data to discriminate among positive and negative samples. Results show how a TCDS-based method provides an alternative mechanism for label-free and automated assays, exhibiting robustness and specificity for genetic detection.
This letter introduces a self-calibrating electrochemical sensor for water acetaminophen detection. The sensor is built upon a graphite pencil lead electrode modified with a molecularly imprinted polymer to ensure selectivity. Moreover, using a sparse identification scheme, the sensor is equipped with a dynamic calibration algorithm to increase the sensor accuracy in time-dependent measurements. The sensor performance was evaluated under static and dynamic conditions using ACT solutions prepared in tap water as the matrix. As a result, the sensor achieved a detection limit of 9.3 mg/L, proving to be a viable alternative for quantifying emerging concerns in water. Finally, we show how simple but robust sensor models could enhance the performance of online measurements
This research reports the development of photocatalytic active composites for hydrogen evolution obtained through high-energy mechanical milling of a mixture of the organic semiconductor g-C3N4 (CN) and the metal–organic framework ZIF-67. These composites, called CNZ-x (X = mass proportion of ZIF-67), were characterized using powder XRD, which showed that the crystalline phases of both the g-C3N4 and ZIF-67 precursors are present in the composites. SEM was used to determine the morphology, revealing that the ZIF-67 octahedral particles adhere to the surface of the CN sheets due to the intimate interfacial contact induced by high-energy mechanical grinding. The results of the photocatalytic evolution of H2 indicate that the CNZ-50 composite produced 261 μmol g−1 of H2, which is higher than the 229.5 and 124 μmol g−1 produced by the precursors ZIF-67 and CN, respectively. The higher efficiency in H2 evolution is due to the composite having better electron-hole separation than the precursor materials.
The presence of water micropollutants, such as antibiotics, has proved the necessity to develop novel and cost‐effective devices for their identification and quantification. These devices aim to save time, reagent usage, and costs associated with conventional analytical methods. In this work, we introduce poly(methylene blue) based screen‐printed electrodes (SPE‐PMB) as electrochemical sensors designed for the quantification of levofloxacin (LVX), given its current prevalence as a micropollutant. Integrating the fabrication and measurement processes into a single electrochemical device is a significant step in creating affordable detection tools. The proposed sensor was assessed using LVX solutions prepared in real groundwater samples, demonstrating its selectivity and achieving a detection limit of 3.3 μM. Finally, we compared the SPE‐PMB sensor and high‐performance liquid chromatography (HPLC) to validate its operation and performance. Consequently, our results suggest that the sensor can be a viable alternative to chromatographic methods for identifying and quantifying micropollutants at very low concentrations in complex matrices.