In this paper, the use of Metal-Organic Framework (MOF) materials as an option for the energy efficiency enhancement of HVAC systems is investigated. In particular, the possibility of using MOFs as dehumidifying materials to reduce the latent load associated with the moisture content of the airflows is studied. A literature review is proposed, highlighting the benefits of using MOFs instead of other adsorbents (e.g., silica-gel) and discussing the unique features (high water uptake capacity and low regeneration temperatures) that make MOFs a preferential desiccant. The possibility to finely tune these properties is also underlined, reporting some explicative examples. A theoretical proposal of a psychrometric transformation, to be performed in a HVAC system equipped with a MOF-Assisted Dehumidifier (MAD), is presented. This transformation is compared with a traditional one (cooling and dehumidification operated by a cooling coil with low temperatures of the coolant). The preliminary numerical simulations, conducted on a reference case study in Florence, Italy, show an estimated energy saving of 30–50%, leading us to consider the use of this technology as a very competitive one in the air-conditioning sector.
The energy and economic performance of a transcritical R744 booster supermarket refrigeration system with and without parallel compression and integrated with an organic Rankine cycle (ORC) was investigated. The results obtained were compared with those of a transcritical R744 booster supermarket refrigeration system with and without parallel compression and those of a conventional R404A direct expansion (DX) system. Nine different locations, namely Copenhagen (Denmark), Paris (France), Athens (Greece), New Delhi (India), Phoenix and Miami (US), Madrid (Spain), Bangkok (Thailand) and Riyadh (Saudi Arabia), were considered. It was discovered that the ORC is effective only at ambient temperatures higher than 27 °C when operating without parallel compression and 28 °C when operating with parallel compression. By using the heat recovered from the gas cooler to fuel the ORC, the latter was found to be capable of covering between 4% and 24% of the electricity demand of the R744 system in warm and hot climates (without parallel compression). The simple payback period of the additional investment associated with the ORC was found to be between 1.4 and 2.5 years in warm climate locations, while the same was found to be less than about 0.5 years in locations experiencing hot climatic conditions.
The field data from an integrated CO2 refrigeration system installed in a supermarket located north of the capital of Lisbon was analyzed. The goal was to demonstrate the effect and performance of multi-ejectors on a refrigeration system operating in a warm climate. The measurement results for the system with and without activating ejectors were compared. It was observed that the system with a multi-ejector operation had considerable performance superiority. The ejectors improved the cooling capacity of the medium temperature stage of the system by 17.4%. The system with active ejectors had 7.5% less total power consumption compared to the ejector off mode of the same system.
The subcooling potential of a novel R717-based waste heat-driven multi-ejector chiller (HEC) integrated with an R744 refrigeration system was evaluated for use in supermarkets. The performance was compared with an R744 refrigeration system coupled to R718- and R600a-based HECs, an R744 system equipped with parallel compression (PC), and a standard R744 booster system (CB) in various warm and hot climatic locations. Integration of the R717-based HEC was found to improve the coefficient of performance by 3.7% at 27 °C to 12.1% at 45 °C compared to the R718, and by 1.6% at 27 °C to 7.6% at 45 °C compared to the R600a-based system. The energy-saving potential of the R717 system (6.2% to 9.4%) was also found to be higher than that of the R718 (0.7% to 2.8%) and R600a systems (2.5% to 6.6%). The use of the existing high-pressure controllers of the CB system was found to impose a relatively lower penalty on the system performance compared to the controllers of the PC system. Although the integration of the R718 system incurred a significantly lower additional investment, the recovery time of the R600a-based HEC (2.3–4.8 years) was found to be the shortest.