Creating highly functional prosthetic, orthotic, and rehabilitation devices is a socially relevant scientific and engineering task. Currently, certain constraints hamper the development of such devices. The primary constraint is the lack of an intuitive and reliable control interface working between the organism and the actuator. The critical point in developing these devices and systems is determining the type and parameters of movements based on control signals recorded on an extremity. In the study, we investigate the simultaneous acquisition of electric impedance (EI), electromyography (EMG), and force myography (FMG) signals during basic wrist movements: grasping, flexion/extension, and rotation. For investigation, a laboratory instrumentation and software test setup were made for registering signals and collecting data. The analysis of the acquired signals revealed that the EI signals in conjunction with the analysis of EMG and FMG signals could potentially be highly informative in anthropomorphic control systems. The study results confirm that the comprehensive real-time analysis of EI, EMG, and FMG signals potentially allows implementing the method of anthropomorphic and proportional control with an acceptable delay.
The electrical impedance myography method is widely used in solving bionic control problems and consists of assessing the change in the electrical impedance magnitude during muscle contraction in real time. However, the choice of electrode systems sizes is not always properly considered when using the electrical impedance myography method in the existing approaches, which is important in terms of electrical impedance signal expressiveness and reproducibility. The article is devoted to the determination of acceptable sizes for the electrode systems for electrical impedance myography using the Pareto optimality assessment method and the electrical impedance signals formation model of the forearm area, taking into account the change in the electrophysical and geometric parameters of the skin and fat layer and muscle groups when performing actions with a hand. Numerical finite element simulation using anthropometric models of the forearm obtained by volunteers’ MRI 3D reconstructions was performed to determine a sufficient degree of the forearm anatomical features detailing in terms of the measured electrical impedance. For the mathematical description of electrical impedance relationships, a forearm two-layer model, represented by the skin-fat layer and muscles, was reasonably chosen, which adequately describes the change in electrical impedance when performing hand actions. Using this model, for the first time, an approach that can be used to determine the acceptable sizes of electrode systems for different parts of the body individually was proposed.
This present work is aimed at conducting fundamental and exploratory studies of the mechanisms of electrical impedance signal formation. This paper also considers morphofunctional changes in forearm tissues during the performance of basic hand actions. For this purpose, the existing research benches were modernized to conduct experiments of mapping forearm muscle activity by electrode systems on the basis of complexing the electrical impedance signals and electromyography signals and recording electrode systems’ pressing force using force transducers. Studies were carried out with the involvement of healthy volunteers in the implementation of vertical movement of the electrode system and ultrasound transducer when the subject’s upper limb was positioned in the bed of the stand while performing basic hand actions in order to identify the relationship between the morphofunctional activity of the upper limb muscles and the recorded parameters of the electro-impedance myography signal. On the basis of the results of the studies, including complex measurements of neuromuscular activity on healthy volunteers such as the signals of electro-impedance myography and pressing force, analyses of the morphofunctional changes in tissues during action performance on the basis of ultrasound and MRI studies and the factors influencing the recorded signals of electro-impedance myography are described. The results are of fundamental importance and will enable reproducible electro-impedance myography signals, which, in turn, allow improved anthropomorphic control.
This research aims to study impact of amplitude parameters on electrical impedance myography when volunteers perform actions with different electrode system pressure force to the skin surface. Acquired data can be used in anthropomorphic control systems to improve the accuracy of recognition of the type of action and to improve the quality of proportional control while using electrical impedance myography as a control signal. For this purpose, measurements were made when the volunteers performed a constant-effort grip of the wrist expander while changing the electrode system pressure force to the skin surface. Measurements were carried out on 10 healthy volunteers in the upper third of the forearm. To control displacement and pressure force of the electrode system to the skin surface, a laboratory test stand was developed. It included force sensors, a displacement encoder and a system of stepper motors along the X, Y, and Z coordinates. Electrode system pressure force in the range of 0.2 to 0.5 daN were found to perform best proportional control systems.
The accurate assessment of muscle morphology and function is crucial for medical diagnostics, rehabilitation, and biomechanical research. This study presents a novel methodology for constructing volumetric models of forearm muscles based on three-dimensional ultrasound imaging integrated with a robotic system to ensure precise probe positioning and controlled pressure application. The proposed ultrasound scanning approach combined with a collaborative six-degrees-of-freedom robotic manipulator enabled reproducible and high-resolution imaging of muscle structures in both relaxed and contracted states. A custom-built phantom, acoustically similar to biological tissues, was developed to validate the method. The cross-sectional area of the muscles and the coordinates of the center of mass of the sections, as well as the volume and center of gravity of each muscle, were calculated for each cross-section of the reconstructed forearm muscle models at contraction. The method’s feasibility was confirmed by comparing the reconstructed volumes with anatomical data and phantom measurements. This study highlights the advantages of robotic-assisted ultrasound imaging for non-invasive muscle assessment and suggests its potential applications in neuromuscular diagnostics, prosthetics design, and rehabilitation monitoring.
Background: Cardiovascular magnetic resonance (CMR) is the clinical gold standard for assessing cardiac anatomy and function. However, the manual segmentation of cardiac structures and myocardial infarction (MI) is time-consuming, prone to inter-observer variability, and often depends on contrast-enhanced imaging. Although deep learning (DL) has enabled substantial automation, challenges remain in generalizability, particularly for MI detection from non-contrast cine CMR. Objective: This study proposes a comprehensive DL-based framework for automatic segmentation of cardiac structures and myocardial infarction using contrast-free cine CMR. Methods: The framework integrates multiple convolutional neural network (CNN) architectures for cardiac structure segmentation with an attention-based deep learning model for MI localization. Post-processing refinement using stacked autoencoders and active contour modeling is applied to improve anatomical consistency. Segmentation performance is evaluated using overlap-based and boundary-based metrics, including the Dice Similarity Coefficient (DSC), Mean Contour Distance (MCD), and Hausdorff Distance (HD). Results: The best-performing model achieved Dice scores of 0.93 ± 0.05 for the left ventricular (LV) cavity, 0.89 ± 0.04 for the LV myocardium, and 0.91 ± 0.06 for the right ventricular (RV) cavity, with consistently low boundary errors across all structures. Myocardial infarction segmentation achieved a Dice score of 0.80 ± 0.02 with high recall, demonstrating reliable infarct localization without the use of contrast agents. Conclusions: By enabling accurate cardiac structure and myocardial infarction segmentation from contrast-free cine CMR, the proposed framework supports broader clinical applicability, particularly for patients with contraindications to gadolinium-based contrast agents and in emergency or resource-limited settings. This approach facilitates scalable, contrast-independent cardiac assessment.