Ahmad Hammoud

Mr. Ahmad Hammoud

Bauman Moscow State Technical University
+1
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ABAndrey Briko
Andrey Briko
VKVladislava Kapravchuk
Vladislava Kapravchuk
AKAlexander Kobelev
Alexander Kobelev
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
SSSergey Shchukin
Sergey Shchukin
Creating highly functional prosthetic, orthotic, and rehabilitation devices is a socially relevant scientific and engineering task. Currently, certain constraints hamper the development of such devices. The primary constraint is the lack of an intuitive and reliable control interface working between the organism and the actuator. The critical point in developing these devices and systems is determining the type and parameters of movements based on control signals recorded on an extremity. In the study, we investigate the simultaneous acquisition of electric impedance (EI), electromyography (EMG), and force myography (FMG) signals during basic wrist movements: grasping, flexion/extension, and rotation. For investigation, a laboratory instrumentation and software test setup were made for registering signals and collecting data. The analysis of the acquired signals revealed that the EI signals in conjunction with the analysis of EMG and FMG signals could potentially be highly informative in anthropomorphic control systems. The study results confirm that the comprehensive real-time analysis of EI, EMG, and FMG signals potentially allows implementing the method of anthropomorphic and proportional control with an acceptable delay.

1 January 2002
Verified
Conference Paper
Open access
RPR.L. Patterson
R.L. Patterson
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
JDJ.E. Dickman
J.E. Dickman
SGS. Gerber
S. Gerber
MEM. Elbuluk
M. Elbuluk
EOE. Overton
E. Overton

3 June 2004
Verified
Conference Paper
Open access
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
RPR.L. Patterson
R.L. Patterson
SGS. Gerber
S. Gerber
MEM. Elbuluk
M. Elbuluk
Planetary exploration missions and deep space probes require electrical power management and control systems that are capable of efficient and reliable operation in very low temperature environments. At present, spacecraft operating in the cold environment of deep space carry radioisotope heating units in order to maintain the surrounding temperature of the on-board electronics at approximately 20/spl deg/C. Electronics capable of operation at cryogenic temperatures will not only tolerate the hostile environment of deep space but also reduce system size and weight by eliminating or reducing the radioisotope heating units and their associated structures; thereby reducing system development as well as launch costs. In addition, power electronic circuits designed for operation at low temperatures are expected to result in more efficient systems than those at room temperature. This improvement results from better behavior and tolerance in the electrical and thermal properties of semiconductor and dielectric materials at low temperatures. The Low Temperature Electronics Program at the NASA Glenn Research Center focuses on research and development of electrical components, circuits, and systems suitable for applications in the aerospace environment and deep space exploration missions. Research is being conducted on devices and systems for reliable use down to cryogenic temperatures (as low as -243/spl deg/C or 30 K). Some of the commercial-off-the-shelf as well as developed components that are being characterized includes passive and active devices and circuits. An overview of the NASA Glenn Research Center Low Temperature Electronic Program is presented in this paper. Selected data obtained through in-house components and circuits testing is also discussed.

26 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
ATAlexey Nikolaevich Tikhomirov
Alexey Nikolaevich Tikhomirov
GMGalina Myasishcheva
Galina Myasishcheva
ZSZein Shaheen
Zein Shaheen
AVAlexander Volkov
Alexander Volkov
SSSergey Shchukin
Sergey Shchukin
Vascular tone plays a vital role in regulating blood pressure and coronary circulation, and it determines the peripheral vascular resistance. Vascular tone is dually regulated by the perivascular nerves and the cells in the inside lining of blood vessels (endothelial cells). Only a few methods for measuring vascular tone are available. Because of this, determining vascular tone in different arteries of the human body and monitoring tone changes is a vital challenge. This work presents an approach for determining vascular tone in human extremities based on multi-channel bioimpedance measurements. Detailed steps for processing the bioimpedance signals and extracting the main parameters from them have been presented. A graphical interface has been designed and implemented to display the vascular tone type in all channels with the phase of breathing during each cardiac cycle. This study is a key step towards understanding the way vascular tone changes in the extremities and how the nervous system regulates these changes. Future studies based on records of healthy and diseased people will contribute to increasing the possibility of early diagnosis of cardiovascular diseases.

6 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
ATAlexey Nikolaevich Tikhomirov
Alexey Nikolaevich Tikhomirov
ABAndrey Briko
Andrey Briko
AVAlexander Volkov
Alexander Volkov
AKAida Karapetyan
Aida Karapetyan
SSSergey Shchukin
Sergey Shchukin
The incidence of cardiovascular diseases is continuously increasing around the world. Therefore, the study of new methods for diagnosing cardiovascular diseases is very important. Early diagnosis and evaluation of the effectiveness of treatments are among the most important tasks. In this work, we study changes in vascular compliance and vascular tone of the lower extremities in a patient diagnosed with an early stage of varicose veins. The study is based on recording the bioimpedance signals of the lower extremities and their parts using the Rheo-32 multichannel device. Registration in the monitoring system takes place in two stages: the first in a state of relaxation, and the second after applying a local massage on one of the legs for five minutes. The results indicate a change in the type of vascular tone of the lower extremities after the massage, while the type of vascular tone changes and shifts on average towards the normotonic type. The method proposed in this study makes it possible to quantitatively and qualitatively assess changes in the tone of the vessels of the extremities.

24 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ABAndrey Briko
Andrey Briko
VKVladislava Kapravchuk
Vladislava Kapravchuk
AKAlexander Kobelev
Alexander Kobelev
ATAlexey Nikolaevich Tikhomirov
Alexey Nikolaevich Tikhomirov
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
SSSergey Shchukin
Sergey Shchukin
The electrical impedance myography method is widely used in solving bionic control problems and consists of assessing the change in the electrical impedance magnitude during muscle contraction in real time. However, the choice of electrode systems sizes is not always properly considered when using the electrical impedance myography method in the existing approaches, which is important in terms of electrical impedance signal expressiveness and reproducibility. The article is devoted to the determination of acceptable sizes for the electrode systems for electrical impedance myography using the Pareto optimality assessment method and the electrical impedance signals formation model of the forearm area, taking into account the change in the electrophysical and geometric parameters of the skin and fat layer and muscle groups when performing actions with a hand. Numerical finite element simulation using anthropometric models of the forearm obtained by volunteers’ MRI 3D reconstructions was performed to determine a sufficient degree of the forearm anatomical features detailing in terms of the measured electrical impedance. For the mathematical description of electrical impedance relationships, a forearm two-layer model, represented by the skin-fat layer and muscles, was reasonably chosen, which adequately describes the change in electrical impedance when performing hand actions. Using this model, for the first time, an approach that can be used to determine the acceptable sizes of electrode systems for different parts of the body individually was proposed.