Sergey Shchukin

Dr. Sergey Shchukin


Research Focus & Metrics

Academic Career Length

47Years (1980-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CNChuong Ngo
Chuong Ngo
CMCarlos Munoz
Carlos Munoz
MLMarkus Lüken
Markus Lüken
AHAlfred Hülkenberg
Alfred Hülkenberg
CBCornelius Bollheimer
Cornelius Bollheimer
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
The detection of muscle contraction and the estimation of muscle force are essential tasks in robot-assisted rehabilitation systems. The most commonly used method to investigate muscle contraction is surface electromyography (EMG), which, however, shows considerable disadvantages in predicting the muscle force, since unpredictable factors may influence the detected force but not necessarily the EMG data. Electrical impedance myography (EIM) investigates the change in electrical impedance during muscle activities and is another promising technique to investigate muscle functions. This paper introduces the design, development, and evaluation of a device that performs EMG and EIM simultaneously for more robust measurement of muscle conditions subject to artifacts. The device is light, wearable, and wireless and has a modular design, in which the EMG, EIM, micro-controller, and communication modules are stacked and interconnected through connectors. As a result, the EIM module measures the bioimpedance between 20 and 200 Ω with an error of less than 5% at 140 SPS. The settling time during the calibration phase of this module is less than 1000 ms. The EMG module captures the spectrum of the EMG signal between 20–150 Hz at 1 kSPS with an SNR of 67 dB. The micro-controller and communication module builds an ARM-Cortex M3 micro-controller which reads and transfers the captured data every 1 ms over RF (868 Mhz) with a baud rate of 500 kbps to a receptor connected to a PC. Preliminary measurements on a volunteer during leg extension, walking, and sit-to-stand showed the potential of the system to investigate muscle function by combining simultaneous EMG and EIM.

27 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ABAndrey Briko
Andrey Briko
VKVladislava Kapravchuk
Vladislava Kapravchuk
AKAlexander Kobelev
Alexander Kobelev
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
SSSergey Shchukin
Sergey Shchukin
Creating highly functional prosthetic, orthotic, and rehabilitation devices is a socially relevant scientific and engineering task. Currently, certain constraints hamper the development of such devices. The primary constraint is the lack of an intuitive and reliable control interface working between the organism and the actuator. The critical point in developing these devices and systems is determining the type and parameters of movements based on control signals recorded on an extremity. In the study, we investigate the simultaneous acquisition of electric impedance (EI), electromyography (EMG), and force myography (FMG) signals during basic wrist movements: grasping, flexion/extension, and rotation. For investigation, a laboratory instrumentation and software test setup were made for registering signals and collecting data. The analysis of the acquired signals revealed that the EI signals in conjunction with the analysis of EMG and FMG signals could potentially be highly informative in anthropomorphic control systems. The study results confirm that the comprehensive real-time analysis of EI, EMG, and FMG signals potentially allows implementing the method of anthropomorphic and proportional control with an acceptable delay.

1 January 2017 in Journal of Electrical Bioimpedance
Verified
Journal Article
Open access
PDF file
MAMugeb Baggash Al-Harosh
Mugeb Baggash Al-Harosh
SSSergey Shchukin
Sergey Shchukin
The electrical impedance method of peripheral vein detection is a novel approach, which offers the advantages of not being expensive and the capability of minimizing and reducing the difficulty of achieving intravenous access in many patients, especially pediatric and obese patients. The electrical impedance method of peripheral vein detection is based on the measurement of electrical impedance using the 4-electrode technique by applying a known alternating current of frequency 100 kHz and constant amplitude to a set of current electrodes and measuring the resulting surface potential at two separate electrodes. This paper presents the results of investigations to estimate the efficiency of this method.

17 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MAMugeb Al-harosh
Mugeb Al-harosh
Marat YangirovMarat Yangirov
Marat Yangirov
DKDmitry Kolesnikov
Dmitry Kolesnikov
SSSergey Shchukin
Sergey Shchukin
The real-time artery diameter waveform assessment during cardio cycle can allow the measurement of beat-to-beat pressure change and the long-term blood pressure monitoring. The aim of this study is to develop a self-calibrated bio-impedance-based sensor, which can provide regular measurement of the blood-pressure-dependence time variable parameters such as the artery diameter waveform and the elasticity. This paper proposes an algorithm based on analytical models which need prior geometrical and physiological patient parameters for more appropriate electrode system selection and hence location to provide accurate blood pressure measurement. As a result of this study, the red cell orientation effect contribution was estimated and removed from the bio-impedance signal obtained from the artery to keep monitoring the diameter waveform correspondence to the change of blood pressure.
1

1 May 2018
Verified
Conference Paper
Closed access
AKAlexander Kobelev
Alexander Kobelev
SSSergey Shchukin
Sergey Shchukin
This work is dedicated neuromuscular interface, which is based on electrical impedance and surface electromyogram registered together. Active part of impedance is registered non-invasively using tetrapolar electrode system from a segment of the upper limb. Impedance signals are proportional to the movement's extent. In contrast to other techniques, this approach allows anthropomorphic bioelectric prosthesis control.

26 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmad HammoudAhmad Hammoud
Ahmad Hammoud
ATAlexey Nikolaevich Tikhomirov
Alexey Nikolaevich Tikhomirov
GMGalina Myasishcheva
Galina Myasishcheva
ZSZein Shaheen
Zein Shaheen
AVAlexander Volkov
Alexander Volkov
SSSergey Shchukin
Sergey Shchukin
Vascular tone plays a vital role in regulating blood pressure and coronary circulation, and it determines the peripheral vascular resistance. Vascular tone is dually regulated by the perivascular nerves and the cells in the inside lining of blood vessels (endothelial cells). Only a few methods for measuring vascular tone are available. Because of this, determining vascular tone in different arteries of the human body and monitoring tone changes is a vital challenge. This work presents an approach for determining vascular tone in human extremities based on multi-channel bioimpedance measurements. Detailed steps for processing the bioimpedance signals and extracting the main parameters from them have been presented. A graphical interface has been designed and implemented to display the vascular tone type in all channels with the phase of breathing during each cardiac cycle. This study is a key step towards understanding the way vascular tone changes in the extremities and how the nervous system regulates these changes. Future studies based on records of healthy and diseased people will contribute to increasing the possibility of early diagnosis of cardiovascular diseases.