Vytautas Daunoras

Dr. Vytautas Daunoras

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Measurement
Verified
Journal Article
Closed access
ZNZilvinas Nakutis
Zilvinas Nakutis
PKPaulius Kaškonas
Paulius Kaškonas
MSMarius Saunoris
Marius Saunoris
Vytautas DaunorasVytautas Daunoras
Vytautas Daunoras
MJMarko Jurcevic
Marko Jurcevic

23 December 2018 in Energies
Verified
Journal Article
Open access
PDF file
RLRobertas Lukočius
Robertas Lukočius
ZNZilvinas Nakutis
Zilvinas Nakutis
Vytautas DaunorasVytautas Daunoras
Vytautas Daunoras
RDRamunas Deltuva
Ramunas Deltuva
PKPranas Kuzas
Pranas Kuzas
RRRoma Rackiene
Roma Rackiene
Smart energy meters supporting bidirectional data communication enable novel remote error monitoring applications. This research targets characterization of the systematic worst-case error of the previously published remote watthour meter’s gain estimation method based on the comparison of synchronous measurements by the reference and meter under test. To achieve the research aim a methodology based on global maximization of the systematic error objective function assuming the typical low voltage electrical distribution network operation parameters ranges as defined by the standard recommendations for network design. To cross verify the reliability of the assessed solutions the suggested error analysis methodology was implemented utilizing two stochastic global extremum search techniques (genetic algorithms, pattern search) and the third one utilizing nonlinear programming solver. It was determined that the wattmeter adjustment gain worst-case error does not exceed 0.5% if the remote wattmeter monitored load power factor is larger than 0.1 and a network is designed according to the recommendation of the acceptable voltage drop less than 5%. For a load exhibiting power factor larger than cos φ = 0.9 the worst-case error was found to be less than 0.1%. It is concluded therefore that considering the systematic worst-case error the previously suggested remote wattmeter adjustment gain estimation method is suitable for remote error monitoring of Class 2 and Class 1 wattmeters.

1 May 2017
Verified
Conference Paper
Closed access
ZNZilvinas Nakutis
Zilvinas Nakutis
MSMarius Saunoris
Marius Saunoris
RRRamunas Ramanauskas
Ramunas Ramanauskas
Vytautas DaunorasVytautas Daunoras
Vytautas Daunoras
In the paper a new method for remote wattmeter calibration is introduced. The implementation of such a type of calibration becomes possible if a remote and a reference wattmeter are connected to the same electrical grid and are equipped with data communication channel. This is a typical situation in smart grid. The main idea of the method is based on switching additional not necessarily precisely known load at the site of calibrated device and obtaining simultaneous active power readings of reference and calibrated devices. The acquired readings are then processed according to the proposed algorithm in order to derive multiplicative calibration coefficient of the calibrated wattmeter. The method aims to cancel the influence of an unknown media (electrical grid wiring and variety of loads) used to propagate measurement unit (active power in watts) between reference and calibrated device assuming that the characteristics of media are constant during the short calibration period. Using simulation of the proposed remote calibration setup it is demonstrated that the method ensures good calibration precision in case of typical power losses in the network.

15 October 2025 in IEEE Access
Verified
Journal Article
Open access
ZNZilvinas Nakutis
Zilvinas Nakutis
MSMarius Saunoris
Marius Saunoris
EVEvaldas Vaiciukynas
Evaldas Vaiciukynas
Vytautas DaunorasVytautas Daunoras
Vytautas Daunoras
JŠJulius Šaltanis
Julius Šaltanis
RLRobertas Lukočius
Robertas Lukočius
Remote in-service detection of energy metering anomalies and identification of faulty meters remains an active challenge due to the limitations of existing methods. Traditional energy conservation-based techniques require readings from all consumers’ meters and are not applicable in the case of partial deployment of smart meters in the distribution grid. This paper presents two novel methods for remote estimation of active power measurement error of individual smart energy meter that utilizes consumer-side power events. The first approach, Inverse Problem Solution (IPS), utilizes feedforward neural network model trained under reference conditions for the prediction of the expected power change at the location of the sum meter. The power measurement gain error of the consumer meter is estimated by minimizing the difference between the predicted power change and the power change measured by the sum meter. The second approach, Electrical Data Augmentation (EDA), utilizes feature engineering with injection of different levels of gain error of meter power measurement to create dataset for the training of a random forest regression model dedicated to predict the gain error directly. Both techniques were examined using synthetic datasets generated from power flow simulation of low-voltage distribution grid. It is shown that both methods achieve sub-1% root mean square error (RMSE) of estimation of power measurement gain error, with EDA demonstrating slightly superior performance in terms of meter error prediction RMSE and robustness to grid technical losses variations.

25 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMarius Saunoris
Marius Saunoris
JŠJulius Šaltanis
Julius Šaltanis
RLRobertas Lukočius
Robertas Lukočius
Vytautas DaunorasVytautas Daunoras
Vytautas Daunoras
KZKasparas Zulonas
Kasparas Zulonas
ZNZilvinas Nakutis
Zilvinas Nakutis
This research targets prediction of power consumption change (PCC) in the branch of electrical distribution grid between a sum meter and consumer meter in response to consumer load change. The problem is relevant for power preservation law-based event-driven methods aiming for detection of anomalies like meter errors, electricity thefts, etc. The PCC in the branch is due to the change of technical (wiring) losses as well as change of power consumption of loads connected to the same distribution branch. Using synthesized dataset set a data-driven model is built to predict PCC in the branch. Model performance is assessed using root mean squared error (RMSE), mean absolute, and mean relative error, together with their standard deviations. The preliminary experimental verification using a test bed confirmed the potential of the method. The accuracy of the PCC in the branch prediction is influenced by the systematic error of the meters. Therefore, the error of the consumer meter and the PCC in the branch cannot be evaluated separately. It was observed that the absolute error of the estimate of power measurement gain error was observed to be within ±0.3% and the relative error of PCC in the branch prediction was within ±10%.

20 June 2026 in Smart Cities
Verified
Journal Article
Open access
PDF file
JŠJulius Šaltanis
Julius Šaltanis
MSMarius Saunoris
Marius Saunoris
RLRobertas Lukočius
Robertas Lukočius
Vytautas DaunorasVytautas Daunoras
Vytautas Daunoras
KZKasparas Zulonas
Kasparas Zulonas
ZNZilvinas Nakutis
Zilvinas Nakutis
Smart energy meters are widely deployed in modern distribution networks, extending their role beyond revenue billing to real-time monitoring and data-driven smart city applications. However, conventional legal metrology frameworks rely on periodic recalibration and are not intended for the detection of accuracy drift or unexpected malfunctions between scheduled inspections. In scientific publications, various techniques for remote smart meters’ error surveillance are presented, but experimental verification on real distribution network data remains limited. The objective of this study is to experimentally verify two previously proposed power event-driven methods for remote estimation of active power measurement error in individual consumer meters, using a feeder-level sum meter as a reference instrument. One-second resolution electrical readings were collected from a real low-voltage distribution branch using ESP32-based local adapters communicating via MQTT over Wi-Fi, with SNTP-based clock synchronization for power event correlation. Under optimized detection parameters, the linear regression method achieved 0.20% RMSE and 0.75% maximum absolute error, and the neural network method 0.09% RMSE and 0.31%, confirming suitability for Class 1 m accuracy surveillance. Feasibility analysis of three MQTT-based deployment scenarios demonstrates that binary encoding limits local adapter buffers to 2.8 kB and worst-case daily channel demand to 2000 kB, confirming the practical viability of the proposed architecture.