Wenxuan Zhao

Dr. Wenxuan Zhao

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
MGMengqi Guo
Mengqi Guo
WZWenxuan Zhao
Wenxuan Zhao
XZXiaowei Zhang
Xiaowei Zhang
Zhengtao AiZhengtao Ai
Zhengtao Ai
RZRongpeng Zhang
Rongpeng Zhang
The COVID-19 pandemic has led to significant increases in morbidity, mortality, and energy consumption, primarily due to infection control measures. Hospitals, as frontline responders, are particularly vulnerable to infection risks due to dense populations and numerous viral carriers. Integrating natural ventilation to optimize air-conditioning systems is crucial for mitigating these risks while balancing energy efficiency. However, existing research has predominantly focused on mechanical ventilation upgrades, with limited attention given to the effective integration of natural ventilation. This study presents an innovative air-conditioning system that incorporates easily installable automatic window control units into existing fresh-air-handling units and fan coil unit systems. This approach allows for multi-zone simultaneous control, making it suitable for both new and retrofitted hospitals. Additionally, the study proposes an optimal multi-zone ventilation strategy aimed at reducing infection risks while enhancing energy efficiency. The performance of the proposed system and ventilation strategy is evaluated considering five common respiratory diseases, with their seasonal transmission characteristics across a wide range of climatic conditions integrated into a revised version of the traditional Wells–Riley equations. The results demonstrate that conventional systems, following China’s GB55015-2021 standard, incur high infection risks during peak-season hours for COVID-19 (1347 h), influenza (470 h), and measles (1386 h). In contrast, the proposed multi-zone ventilation strategy eliminates infection risks while only increasing energy consumption by 3–10%, utilizing outdoor wind pressure as a key resource. This solution not only enhances hospital resilience but also provides valuable technical guidance for the design and retrofitting of hospital buildings, ensuring enhanced infection control and energy efficiency across diverse climates.

25 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
KPKai Peng
Kai Peng
MMMingzhu Ma
Mingzhu Ma
WZWenxuan Zhao
Wenxuan Zhao
RZRongpeng Zhang
Rongpeng Zhang
Solar power is widely regarded as one of the most promising renewable resources for generating electricity and reducing building energy consumption. Logistics parks, with their low-rise buildings and extensive rooftop areas, offer significant advantages for solar energy utilization via rooftop photovoltaics (PVs). However, limited research has been conducted on the proper operational principles and optimized control strategies for the PV systems of logistics parks, particularly regarding the mismatch between power generation and the loads of various building types under varying climatic conditions. This study proposes four optimal PV operation strategies for large-scale logistics parks across diverse climatic regions, developed using a multi-criteria optimization approach. The strategies optimize the azimuth and tilt angles of PV panels under four adjustment frequencies: annual, semi-annual, seasonal, and monthly. The investigated strategies are validated in a 5500 m2 logistics park, comprising refrigerated storage, warehouses, sorting centers, and other facilities. The results indicate that the proposed strategies outperform conventional fixed-angle approaches, with the monthly adjustment strategy delivering the best performance. Economic costs are reduced by 9.26–17.02%, while self-sufficiency can be improved by 2.00–7.08%. Cold regions with high solar radiation show particularly significant benefits, with self-consumption increasing by 82.44–359.04%. This study provides valuable insights and practical guidelines for optimizing PV system operations in logistics parks, offering enhanced energy efficiency and cost-effectiveness.

9 June 2026 in Energy
Verified
Journal Article
Closed access
RLRuimiao Liu
Ruimiao Liu
WZWenxuan Zhao
Wenxuan Zhao
PWPengcheng Wang
Pengcheng Wang
YWYaling Wu
Yaling Wu
CZChunyu Zhou
Chunyu Zhou
ZLZhongbing Liu
Zhongbing Liu