Yipei Wang

Prof. Yipei Wang

Institute of Automation, Qilu University of Technology (Shandong Academy of Sciences), Jinan, Shandong, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Yipei WangYipei Wang
Yipei Wang
JYJi-Woong Yang
Ji-Woong Yang
WKWoo-Joon Kim
Woo-Joon Kim
TKTae-Ho Kwon
Tae-Ho Kwon
TLTaewon Lee
Taewon Lee
PSPark Sung-jun
Park Sung-jun
Electric vehicles interconnect and interact with the grid bidirectionally through a vehicle-to-grid (V2G) system. In V2G, the output power on the ac side pulsates at twice the grid frequency 2 f o , which leads to the presence of a second harmonic current (SHC) on the dc side and reduces the reliability of the system. A bandstop filter with a center frequency of 2 f o is introduced in the voltage sampling loop to suppress the SHC. A digital implementation of the BSF is proposed to apply at arbitrary frequencies, which avoids the cost increase and provides high simplicity and flexibility. An adaptive PI control method is further proposed to improve the dynamic performance, which adjusts the PI parameters in real-time according to the inductor current. A 3.5 kW V2G experimental prototype is built and tested to verify the feasibility and stability of the proposed strategies. The prototype offers an excellent dynamic and steady-state response in stand-alone and grid-tie modes.

30 May 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Yipei WangYipei Wang
Yipei Wang
SKSoo-Yeon Kim
Soo-Yeon Kim
YCYafei Chen
Yafei Chen
HZHailong Zhang
Hailong Zhang
SPSung-Jun Park
Sung-Jun Park
A switching mode power supply (SMPS)-based lithium-ion (Li-ion) battery test system (BTS) is proposed to meet the increasing demands of tests in battery research. To improve the flexibility, while building the BTS with low cost and high reliability, an SMPS is employed as a charger/discharger, combined with a digital-to-analog hybrid control system to regulate its output voltage and current. Based on the BTS, two dc internal resistance (DCIR) measurement methods are designed, and a battery state classification method based on the DCIR cluster analysis with similarity as the judgment basis is proposed. An experimental prototype is developed to verify the feasibility of the proposed BTS and methods. The results show that the BTS possesses excellent voltage and current regulation capabilities for charging, discharging, and grid energy recovery. The internal parameter extraction method enables obtaining DCIR and other parameters with high accuracy. The online measurement method allows automatic acquisition of real-time DCIR and its variation trend without affecting the charging, which greatly improves the measurement efficiency. The proposed hierarchical clustering method based on DCIR effectively achieves the classification of battery states with excellent practicality and robustness.

20 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HYHongzhi Yang
Hongzhi Yang
ZSZibo Sun
Zibo Sun
HWHaoran Wang
Haoran Wang
Yipei WangYipei Wang
Yipei Wang
MZMengmei ZHU
Mengmei ZHU
HLHongzhang Lyu
Hongzhang Lyu
The droop control strategy, known for its communication-free nature, is widely adopted for the parallel operation of inverter units. However, in microgrids, mismatches in line impedances and various measurement inaccuracies often lead to imbalanced reactive power sharing among inverters and significant circulating current. To address these challenges, this paper proposes an adaptive droop control method that relies solely on local measurements from each inverter, eliminating the need for communication. The proposed approach integrates the deviation between the ratio of reactive power to output voltage and its reference value to generate an Adaptive Virtual Impedance Droop Control (AVIDC) mechanism. This enables a dynamic balance between reactive power output and voltage drop. The simulation and experimental results validate the effectiveness of the proposed control strategy, demonstrating a significant improvement in the accuracy of reactive power sharing.

15 October 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ALAncheng Liu
Ancheng Liu
Yipei WangYipei Wang
Yipei Wang
TKTaeho Kwon
Taeho Kwon
PSPark Sung-jun
Park Sung-jun
In PV grid-connected applications, a grid-connected converter is usually used to connect with the grid to realize dc/ac conversion and power flow control. How to improve the quality of grid-connected current of power equipment so that the harmonic content injected into the grid is as little as possible has become a hot research topic in the field of PV grid-connected applications. By analyzing the causes of grid-connected harmonic currents during the grid-connection process, a two-segment high-performance grid-connected inverter topology is proposed. This structure makes the main inverter basically equal to the grid voltage through the simplest closed-loop control. Since the voltage sensitivity of the auxiliary inverter is low, utilizing the auxiliary inverter for the compensation of grid-connected voltage and grid-connected control of power flow will lead to an improvement in the quality of grid-connected current. A 3.3 kW grid-connected inverter system prototype is fabricated and tested, and the experimental results verify the stability and effectiveness of the theoretical analysis and the proposed control scheme.

21 December 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Yipei WangYipei Wang
Yipei Wang
ALAncheng Liu
Ancheng Liu
YZYaochen Zhu
Yaochen Zhu
HZHailong Zhang
Hailong Zhang
YCYafei Chen
Yafei Chen
PSPark Sung-jun
Park Sung-jun
In this article, an adaptive fast charging strategy for lithium-ion batteries considering the variation of dc internal resistance (DCIR) is proposed, which applies to mobile applications. The experiments prove that the DCIR obeys the Gaussian distribution during the normal charging stage. However, the DCIR no longer obeys Gaussian distribution once the battery is fully charged. The proposed strategy employs the maximum-likelihood method to estimate the expectation and variance of the Gaussian distribution. The charging mode switches from constant current (CC) to constant voltage (CV) immediately when the DCIR deviates significantly from the expectation. Under the premise of satisfying the high accuracy for the parameter estimates, a constrained optimization problem is established to determine the DCIR minimum number of measurements ( n min ), and the constraints are transformed into hypothesis testing for solving. The CC operating time is maximized based on n min and the adaptive control of the transition point. The experiments verify the validity of the proposed method. The results show that compared with the CC-CV method, the proposed strategy saves 52.2%, 41.57%, and 29.72% of the charging time at 1C, 0.75C, and 0.5C, respectively, which effectively improves the charging speed and prevents overcharging.

22 January 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MKMin-Seong Kim
Min-Seong Kim
SLSang-Hyeok Lee
Sang-Hyeok Lee
TLTuan-Vu Le
Tuan-Vu Le
HGHyeon-Uk Go
Hyeon-Uk Go
PSPark Sung-jun
Park Sung-jun
Yipei WangYipei Wang
Yipei Wang
When the three-phase grid voltage is distorted, the grid current total harmonic distortion (THD) will deteriorate accordingly in VIENNA rectifier. This paper proposes a current harmonic suppression strategy based on real-time discrete Fourier transform (DFT). The DFT is employed to extract the sine and cosine components of the grid current high-order harmonics, which are applied to the feedback loop of the dq rotating coordinate system. Independent control loops for high-order harmonic currents are introduced, and the references are set as 0 to suppress the corresponding harmonic currents. The difference between the control strategies of positive and negative sequence components is discussed. The proposed control method can be extended to other orders. To verify the validity of the proposed strategy, a 50 kW VIENNA rectifier prototype is designed and built. The experimental results show that the current THD is improved under grid voltage distortion over the entire load range.