21 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
CSCamila Salomon
Camila Salomon
CFClaudio Ferreira
Claudio Ferreira
Wilson SantanaWilson Santana
Wilson Santana
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
LSLuiz Eduardo Borges da Silva
Luiz Eduardo Borges da Silva
BTBruno Silva Torres
Bruno Silva Torres
The condition of synchronous generators (SGs) is a matter of great attention, because they can be seen as equipment and also as fundamental elements of power systems. Thus, there is a growing interest in new technologies to improve SG protection and maintenance schemes. In this context, electrical signature analysis (ESA) is a non-invasive technique that has been increasingly applied to the predictive maintenance of rotating electrical machines. However, in general, the works applying ESA to SGs are focused on isolated machines. Thus, this paper presents a study on the condition monitoring of SGs in bulk electric systems by using ESA. The main contribution of this work is the practical results of ESA for fault detection in in-service SGs interconnected to a power system. Two types of faults were detected in an SG at a Brazilian hydroelectric power plant by using ESA, including stator electrical unbalance and mechanical misalignment. This paper also addresses peculiarities in the ESA of wound rotor SGs, including recommendations for signal analysis, how to discriminate rotor faults on fault patterns, and the particularities of two-pole SGs.

10 June 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CSCamila Salomon
Camila Salomon
Wilson SantanaWilson Santana
Wilson Santana
LSLuiz E. Borges da Silva
Luiz E. Borges da Silva
GLGermano Lambert-Torres
Germano Lambert-Torres
EBErik L. Bonaldi
Erik L. Bonaldi
JSJonas G. Borges da Silva
Jonas G. Borges da Silva
This paper presents an air-gap torque (AGT)-based method for efficiency estimation of induction motors. A new concept of stator resistance that includes the mechanical losses effect is proposed. This new stator resistance is estimated through a particle swarm optimization approach based on the stator flux equations and minimization of torque error at the rated operation point. Then, the obtained stator resistance is used in the AGT equations to estimate the shaft torque and then the efficiency. Moreover, the rotor speed is estimated using induction motor current signature analysis. Thus, the proposed methodology for induction motor efficiency estimation relies only on line currents, line voltages, and nameplate data, being appropriate for in-service applications. Finally, the simulation and experimental results are presented to validate the proposed method at different load conditions.

26 September 2016 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CSCamila Paes Salomon
Camila Paes Salomon
Wilson SantanaWilson Santana
Wilson Santana
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
LSLuiz Eduardo Borges da Silva
Luiz Eduardo Borges da Silva
EBErik Leandro Bonaldi
Erik Leandro Bonaldi
MLMarco Aurelio Araujo Lopes
Marco Aurelio Araujo Lopes
Electrical signature analysis (ESA) has been successfully applied to predictive maintenance of synchronous machines. The fault diagnosis is performed by analyzing failure patterns in the current or voltage spectra, which allow the discrimination of a healthy and a faulty condition on the monitored machine. Generally, the failure patterns are a function of the line frequency, rotor rotation frequency, and some structure features of the machine. The rotor rotation frequency pattern, for instance, is indicative of rotor mechanical problems and rotor winding interturn short-circuit. An increase of this frequency component magnitude may indicate the incipience of a rotor fault but may not discriminate the nature of the fault (electrical or mechanical). Thus, it is necessary to distinguish the effects of electrical and mechanical faults in these components in order to get a reliable diagnosis of the machine. No works have been found in the literature approaching this specific issue. This paper proposes a simple and innovative methodology to distinguish the effect of electrical and mechanical faults in the mentioned ESA failure patterns based on the method of symmetrical components. Its effectiveness is validated by experiments performed on a synchronous generator test rig. The proposed condition monitoring system is simple, low cost, and low intrusive, as it only relies on stator electrical quantities. Moreover, it is in operation in a Brazilian 404-MW thermal power station.

31 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TZTiago Zacarias
Tiago Zacarias
Wilson SantanaWilson Santana
Wilson Santana
This paper presents a literature review on the subject of Condition-Based Maintenance of surge arresters. Both a bibliometric analysis and traditional comprehensive research are presented. The bibliometric analysis is useful for obtaining insights about the literature. It quantitatively highlights relationships between journals, authors and keywords (related to the monitoring methods) and reveals future trends for research based on the timeline of the keywords. The traditional comprehensive literature review is also presented. It summarizes the methods, their advantages and disadvantages and also points to some known measurement issues of the methods. Both online (leakage current, harmonic components, temperature, partial discharges, power loss and the counting of discharges) and offline (reference voltage, residual voltage, insulation resistance, polarization/depolarization, return voltage, microscopy, spectrometry, X-ray, RUS and the recent application of FRA) methods have been qualitatively analyzed.

2 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Wilson SantanaWilson Santana
Wilson Santana
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
Erik Leandro BonaldiErik Leandro Bonaldi
Erik Leandro Bonaldi
BGBruno Renó Gama
Bruno Renó Gama
TZTiago Zacarias
Tiago Zacarias
FSFabio Monteiro Steiner
Fabio Monteiro Steiner
This paper presents an innovative concept for the online application of Frequency Response Analysis (FRA). FRA is a well known technique that is applied to detect damage in electric machinery. As an offline technique, the machine under testing has to be removed from service—which may cause loss of production. Experimental adaptations of FRA to online operation are usually based on the use of passive high pass coupling—which, ideally, should provide attenuation to the grid voltage, and at the same time, allow the high frequency FRA signals to be injected at the machine. In practice, however, the passive coupling results in a trade-off between the required attenuation and the useful area obtained at the FRA spectra. This paper proposes the use of an active coupling system, based on power electronics, in order to cancel the grid voltage at the terminals of FRA equipment and allow its safe connection to an energized machine. The paper presents the basic concepts of FRA and the issue of online measurements. It also presents basic concepts about power electronics converters and the operating principles of the Modular Multilevel Converter, which enables the generation of an output voltage with low THD, which is important for tracking the grid voltage with minimum error.

21 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
CSCamila Salomon
Camila Salomon
Wilson SantanaWilson Santana
Wilson Santana
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
LSLuiz Eduardo Borges da Silva
Luiz Eduardo Borges da Silva
Erik Leandro BonaldiErik Leandro Bonaldi
Erik Leandro Bonaldi
LOLevy Oliveira
Levy Oliveira
Induction motors consume a great portion of the generated electrical energy. Moreover, most of them work at underloaded conditions, so they have low efficiencies and waste a lot of energy. Because of this, the efficiency estimation of in-service induction motors is a matter of great importance. This efficiency estimation is usually performed through indirect methods, which do not require invasive measurements of torque or speed. One of these methods is the modified Air-Gap Torque (AGT) method, which only requires voltage and current data, the stator resistance value, and the mechanical losses. This paper approaches the computation of a modified stator resistance including the mechanical losses effect to be applied in the AGT method for torque and efficiency estimation of induction motors. Some improvements are proposed in the computation of this resistance by using a direct method, as well as the possibility to estimate this parameter directly from the nameplate data of the induction motor. The proposed methodology only relies on line voltages, currents, and nameplate data and is not intrusive. The proposed methodology is analyzed through simulation and validated through experimental results with three-phase induction motors. Also, a comparison of methods for in-service induction motors efficiency estimation is presented for the tested motors.