Tiago Zacarias

Dr. Tiago Zacarias

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TZTiago Zacarias
Tiago Zacarias
Wilson SantanaWilson Santana
Wilson Santana
This paper presents a literature review on the subject of Condition-Based Maintenance of surge arresters. Both a bibliometric analysis and traditional comprehensive research are presented. The bibliometric analysis is useful for obtaining insights about the literature. It quantitatively highlights relationships between journals, authors and keywords (related to the monitoring methods) and reveals future trends for research based on the timeline of the keywords. The traditional comprehensive literature review is also presented. It summarizes the methods, their advantages and disadvantages and also points to some known measurement issues of the methods. Both online (leakage current, harmonic components, temperature, partial discharges, power loss and the counting of discharges) and offline (reference voltage, residual voltage, insulation resistance, polarization/depolarization, return voltage, microscopy, spectrometry, X-ray, RUS and the recent application of FRA) methods have been qualitatively analyzed.

2 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Wilson SantanaWilson Santana
Wilson Santana
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
Erik Leandro BonaldiErik Leandro Bonaldi
Erik Leandro Bonaldi
BGBruno Renó Gama
Bruno Renó Gama
TZTiago Zacarias
Tiago Zacarias
FSFabio Monteiro Steiner
Fabio Monteiro Steiner
This paper presents an innovative concept for the online application of Frequency Response Analysis (FRA). FRA is a well known technique that is applied to detect damage in electric machinery. As an offline technique, the machine under testing has to be removed from service—which may cause loss of production. Experimental adaptations of FRA to online operation are usually based on the use of passive high pass coupling—which, ideally, should provide attenuation to the grid voltage, and at the same time, allow the high frequency FRA signals to be injected at the machine. In practice, however, the passive coupling results in a trade-off between the required attenuation and the useful area obtained at the FRA spectra. This paper proposes the use of an active coupling system, based on power electronics, in order to cancel the grid voltage at the terminals of FRA equipment and allow its safe connection to an energized machine. The paper presents the basic concepts of FRA and the issue of online measurements. It also presents basic concepts about power electronics converters and the operating principles of the Modular Multilevel Converter, which enables the generation of an output voltage with low THD, which is important for tracking the grid voltage with minimum error.

16 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TZTiago Zacarias
Tiago Zacarias
RMRafael Martins
Rafael Martins
CXCarlos Eduardo Xavier
Carlos Eduardo Xavier
JCJulio Cezar Oliveira Castioni
Julio Cezar Oliveira Castioni
Wilson SantanaWilson Santana
Wilson Santana
FAFrederico De Oliveira Assuncao
Frederico De Oliveira Assuncao
This work presents an innovative application of Frequency Response Analysis (FRA) in order to detect early degradation of Metal Oxide Surge Arresters (MOSAs). This technique has been widely used in power transformers, but has never been applied to MOSAs. It consists in comparisons of spectra, measured at different instants of the lifetime of the arrester. Differences between these spectra are an indicator that some electrical properties of the arrester have changed. An incremental deterioration test has been performed on arrester samples (with controlled circulation of leakage current, which increases the energy dissipation over the device), and the FRA spectra correctly identified the progression of damage. Although preliminary, the FRA results seemed promising, and it is expected that this technology could be used as another diagnostic tool for arresters.

3 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
FDFabio Henrique de Souza Duz
Fabio Henrique de Souza Duz
TZTiago Zacarias
Tiago Zacarias
Ronny Francis Ribeiro JuniorRonny Francis Ribeiro Junior
Ronny Francis Ribeiro Junior
FSFabio Monteiro Steiner
Fabio Monteiro Steiner
FAFrederico Assunção
Frederico Assunção
LBLuiz Eduardo Borges-Da-Silva
Luiz Eduardo Borges-Da-Silva
Power transformers are critical components in electrical power systems, where failures can cause significant outages and economic losses. Traditional maintenance strategies, typically based on offline inspections, are increasingly insufficient to meet the reliability requirements of modern digital substations. This work presents an integrated multi-sensor monitoring framework that combines online frequency response analysis (OnFRA® 4.0), capacitive tap-based monitoring (FRACTIVE® 4.0), dissolved gas analysis, and temperature measurements. All data streams are synchronized and managed within a SCADA system that supports real-time visualization and historical traceability. To enable automated fault diagnosis, a Random Forest classifier was trained using simulated datasets derived from laboratory experiments that emulate typical transformer and bushing degradation scenarios. Principal Component Analysis was employed for dimensionality reduction, improving model interpretability and computational efficiency. The proposed model achieved perfect classification metrics on the simulated data, demonstrating the feasibility of combining high-fidelity monitoring hardware with machine learning techniques for anomaly detection. Although no in-service failures have been recorded to date, the monitoring infrastructure is already tested and validated through laboratory conditions, enabling continuous data acquisition.

1 January 2021 in Brazilian Archives of Biology and Technology
Verified
Journal Article
Open access
CSClailton Leopoldo da Silva
Clailton Leopoldo da Silva
RMRafael Martins
Rafael Martins
CXCarlos Eduardo Xavier
Carlos Eduardo Xavier
JCJúlio Cezar Oliveira Castioni
Júlio Cezar Oliveira Castioni
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
FAFrederico de Oliveira Assunção
Frederico de Oliveira Assunção

1 January 2024 in Brazilian Archives of Biology and Technology
Verified
Journal Article
Open access
PDF file
TZTiago Zacarias
Tiago Zacarias
RMRafael Martins
Rafael Martins
CXCarlos Eduardo Xavier
Carlos Eduardo Xavier
JCJúlio Cezar Oliveira Castioni
Júlio Cezar Oliveira Castioni
Germano Lambert-TorresGermano Lambert-Torres
Germano Lambert-Torres
EBErik Leandro Bonaldi
Erik Leandro Bonaldi
Surge arresters are at the forefront of protection against voltage surges. The loss of the protective effect of surge arresters imposes accidents and unplanned shutdowns on the power system. It directly affects the interruption of power supplies and imposes fines on service providers. Monitoring and diagnostics in the lightning rod field require studies and work that present the degradation behaviour of surge arresters to help develop and improve existing techniques. This paper presents the development of a laboratory with a low-energy, mobile current waveform impulse generator. It allows for conducting aging tests by applying discharges to low-voltage zinc oxide surge arresters used in the energy distribution sector. Samples of surge arresters were subjected to the discharges produced by the developed generator, and they exhibited degradation, thus showing asymmetry between the positive and negative half-cycles of leakage current.