Wioletta Jackiewicz-Rek

Dr. Wioletta Jackiewicz-Rek

Warsaw Univeristy of Technology, Faculty of Civil Engineering
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
TDTomasz Drzymała
Tomasz Drzymała
WJWioletta Jackiewicz-Rek
Wioletta Jackiewicz-Rek
MTMariusz Tomaszewski
Mariusz Tomaszewski
AKArtur Kuś
Artur Kuś
JGJerzy Gałaj
Jerzy Gałaj
RŠRitoldas Šukys
Ritoldas Šukys

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
WJWioletta Jackiewicz-Rek
Wioletta Jackiewicz-Rek
KZKamil Zalegowski
Kamil Zalegowski
Andrzej GarbaczAndrzej Garbacz
Andrzej Garbacz
BBBenoit Bissonnette
Benoit Bissonnette
The paper presents the results of an experimental program intended to assess the potential of sanitary ceramic waste utilization as aggregates in cement-based mortars. Their influence was evaluated with respect to workability (consistency, plasticity, pores volume), mechanical properties (compressive and flexural strength) and freeze-thaw resistance. The results showed that partial replacement of fine aggregate with sanitary ceramic fillers up to 20% of cement by weight improves compressive and flexural strength and reduces shrinkage. The test results were discussed in the lights of the literature data on influence of ceramic waste on properties of fresh and hardened concretes

26 April 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HWHubert Witkowski
Hubert Witkowski
WJWioletta Jackiewicz-Rek
Wioletta Jackiewicz-Rek
Karol ChilmonKarol Chilmon
Karol Chilmon
JJJanusz Jaroslawski
Janusz Jaroslawski
ATAnna Tryfon-Bojarska
Anna Tryfon-Bojarska
AGArkadiusz Gąsiński
Arkadiusz Gąsiński
This paper presents the results of laboratory tests on photocatalytic pavement blocks from a bicycle lane in Poland after seven years of service. Air purification performance was tested on dusty and clean samples using different light sources and setups, with non-laminar gas circulation. Secondary Electrons Secondary Ions (SESI) and InLens detectors combined with SEM–EDS and X-ray analyses were applied to confirm the presence of TiO2 in the studied blocks. The obtained results show that TiO2 was present in the form of agglomerates with a diameter of 0.25–5 µm and was bonded to the cement matrix components. The tested samples still maintained nitric oxide (NO) removal capability with a NO reduction rate of 4–45%, depending on light source and surface cleanliness.

20 March 2018 in JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT
Verified
Journal Article
Open access
PDF file
TDTomasz Drzymała
Tomasz Drzymała
WJWioletta Jackiewicz-Rek
Wioletta Jackiewicz-Rek
JGJerzy Gałaj
Jerzy Gałaj
RŠRitoldas Šukys
Ritoldas Šukys
There has been a tendency to design ever slender building construction using high strength concrete in recent years. Application of HSC is also growing in tunnel construction. One of the most important challenges is to control explosive spalling of concrete and the method recommended by Eurocode 2 (EN 1992-1-2:2008/NA:2010P) is addition of polypropylene fibres to the mix. The purpose of the research described in this paper was to evaluate the changes of mechanical properties of HSC exposed to the effect of high temperature. The tests were carried out on three types of high strength concrete: air-entrained concrete, polypropylene fibre-reinforced concrete and reference concrete having constant water/cement ratio. The properties of hardened concrete including compressive strength, tensile splitting strength, flexural strength and E-modulus were studied. The latter tests were carried out on both on concrete cured at 20 °C and concrete subjected to high-temperature conditions at 300 °C, 450 °C and 600 °C. The results enabled us to evaluate the effect of high-temperature conditions on the properties of high-performance concrete and compare the effectiveness of the two methods designed to improve the high-temperature performance of the concrete: addition of polypropylene fibres and entrainment of air.

25 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
SDSławomir Dudziak
Sławomir Dudziak
WJWioletta Jackiewicz-Rek
Wioletta Jackiewicz-Rek
ZKZofia Kozyra
Zofia Kozyra
The study was devoted to the numerical modelling of concrete-to-concrete interfaces. Such an interface can be found in many modern composite structures, so proper characterisation of its behaviour is of great importance. A strategy for calibration of a model based on cohesive finite elements and the elastic-damage traction–separation constitutive law available by default in the Abaqus code was proposed. Moreover, the default interface material model was enhanced with the user-field-variables subroutine to include a real strength envelope for such interfaces. Afterwards, the modelling approach was validated with numerical simulation of the most popular tests for determining the strength characteristics of concrete-to-concrete interfaces: three-point bending beam with a notch, splitting bi-material cubic specimens, and slant-shear tests. The results of own pilot studies were used as well as those reported by other researchers. The performed simulations proved the accuracy of the proposed modelling strategy (the mean ratio of ultimate forces obtained with numerical models and from experiments was equal to 1.01). Furthermore, the presented examples allowed us to better understand the basic test methods for concrete interfaces and the observed mechanisms of failure during them.

1 December 2016 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
WJWioletta Jackiewicz-Rek
Wioletta Jackiewicz-Rek
TDTomasz Drzymała
Tomasz Drzymała
AKA. Kuś
A. Kuś
MTM. Tomaszewski
M. Tomaszewski
In the recent years a tendency for design of increasingly slender structures with the use of high performance concrete has been observed. Moreover, the use of high performance concrete in tunnel structures, subject to high loads with possibility of extreme loads occurrence such as fire, has an increasing significance.Presented studies aimed at improving high performance concrete properties in high temperature conditions (close to fire conditions) by aeration process, and determining high temperature impact on the concretes features related to their durability.In this paper it has been proven that it is possible to obtain high performance concretes resistant to high temperatures, and additionally that modification of the concrete mix with aerating additive does not result in deterioration of concrete properties when subject to water impact in various form.