Zengyan Zhu

Dr. Zengyan Zhu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DWDayang Wang
Dayang Wang
XLXiaoxiao Liu
Xiaoxiao Liu
YWYutao Wang
Yutao Wang
ZZZengyan Zhu
Zengyan Zhu
DCDawei Chen
Dawei Chen
ZXZhi Xie
Zhi Xie
Gas-solid flows with non-uniform phase distribution and varying moisture often exist in the industrial process. Its solid concentration measurement is an important and challenging research field and new effective measurement methods are needed. In this study, a novel method using the microwave resonant cavity sensor is proposed to measure solid concentration of gas-solid two-phase flow with varying moisture. The sensor is developed from a cylindrical resonant cavity with open ends, and the orthogonal experiment is carried out using simulation method to determine the resonant mode and optimize the sensor configuration. Afterward, experiments are conducted to evaluate the performance of the designed sensor and the proposed method. The sensor has a high and nearly constant sensitivity to the solid concentration and its output is almost not affected by the non-uniform phase distribution. The varying moisture brings effect to solid concentration measurement when the proposed sensor is used. To solve this problem, the new parameter named normalized resonant frequency is defined to reduce this influence and finally the solid concentration measurement is achieved.

25 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DWDayang Wang
Dayang Wang
JSJiuxiang Sun
Jiuxiang Sun
YWYutao Wang
Yutao Wang
GYGang Yang
Gang Yang
ZZZengyan Zhu
Zengyan Zhu
ZXZhi Xie
Zhi Xie
In gas-solid two-phase flow, the situation that the moisture in the solid changes is often encountered. The varying and unknown moisture brings new challenges to the solid concentration measurement if the used measurement method is sensitive to the moisture. In this study, a new method which can eliminate the influence of moisture on the measurement of solid concentration in gas-solid flows is proposed. Firstly, the new combined sensors consisting of the microwave transmission sensor and the capacitance sensor are proposed and the measurement systems are designed. The microwave transmission sensor and the capacitance sensor are both sensitive to the moisture and the solid concentration, and they can acquire the information of the solid concentration and the moisture simultaneously. Then an effective decoupling method is proposed to derive the moisture and the solid concentration from the information acquired by the microwave transmission sensor and the capacitance sensor. Experiments are carried out to simulate the flow structure of roping flow to verify the proposed method. The results indicate that the influence of moisture on the measurement of solid concentration can be eliminated, and moisture independent measurement of solid concentration in gas-solid flows can be realized.

8 July 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
ZZZengyan Zhu
Zengyan Zhu
YWYutao Wang
Yutao Wang
DWDayang Wang
Dayang Wang
GYGang Yang
Gang Yang
ZXZhi Xie
Zhi Xie
In a gas–solid two-phase flow system, simultaneous measurement of solid concentration and solid moisture is essential for some applications. However, during the measurement process, solid concentration and solid moisture are coupled in the measurement signals when the measurement signal is sensitive to both solid concentration and moisture. This makes it challenging to measure them simultaneously in the same measurement field. To solve this issue, a novel measurement method is proposed in this study, which uses a dual-modality electrical sensor to achieve simultaneous measurement of solid concentration and solid moisture in gas–solid two-phase flow. The dual-modality electrical sensor features a simple structure and captures measurement signals of capacitance and angle of dielectric loss within the same measurement section. With the above signals which are both sensitive to solid concentration and moisture, an iterative correction calculation method is adopted to achieve the simultaneous measurement of solid concentration and solid moisture. During the calculation process, the measured parameters are decoupled and continuously corrected until the related error values meet the threshold requirement. Numerical simulation experiments under three typical distributions and physical experiments under roping flow are carried out to verify the proposed measurement method. The results prove the effectiveness of the proposed measurement method in the simultaneous measurement of solid concentration and solid moisture for gas–solid two-phase flow.

30 January 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DWDayang Wang
Dayang Wang
DZDanian Zhang
Danian Zhang
YWYutao Wang
Yutao Wang
ZZZengyan Zhu
Zengyan Zhu
GYGang Yang
Gang Yang
The non-uniform solid distribution and unknown solid moisture content in gas-solid two-phase flow present challenges to the measurement of solid concentration. To address this issue, this paper proposes a novel method for measuring solid concentration by developing a Yagi antenna-based microwave sensor. The dimensions of the Yagi antenna are optimized through finite element simulation to ensure good radiation performance at the working frequency. The optimized Yagi antennas are employed as transmitting unit and receiving unit, forming a novel microwave transmission sensor. Experiments are carried out to assess the sensor performance and its effectiveness in measuring solid concentrations. Experimental results indicate that the measured phase shift exhibits a high sensitivity to changes in solid concentration, and is not sensitive to the non-uniform solid distribution. However, the relation between the measured phase shift and solid concentration is influenced by the moisture content of the solid. In order to eliminate the impact of moisture content on solid concentration measurement, a new parameter named normalized phase shift is defined. The relation between the solid concentration and the normalized phase shift is almost not affected by the moisture content. Consequently, the Yagi antenna-based microwave sensor, combined with the definition of normalized phase shift, allows for accurate measurement of solid concentration under varying moisture conditions.

1 June 2019
Verified
Conference Paper
Closed access
ZZZengyan Zhu
Zengyan Zhu
YWYutao Wang
Yutao Wang
As a visual detection technology, Electrical Impedance Tomography (EIT) can reconstruct the distribution of two types of electric property information (conductivity and permittivity) in target region theoretically. This characteristic of EIT can better compensate for the shortcomings of traditional ERT/ECT dual-modal systems. However, as a technology with great development potential, complex-value EIT has not been investigated systematically. This paper introduces how to establish EIT circular field simulation model, and probes into reconstruction methods of dual-modal information preliminarily. By analyzing the experimental results, it is verified that the data processing method that take complex data as a whole can obtain dual-modal information with complementarity. Complex-value EIT technology can improve system resolution and expand system measuring range.

21 July 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
ZZZengyan Zhu
Zengyan Zhu
DWDayang Wang
Dayang Wang
YLYan Li
Yan Li
The accurate measurement of solid concentration in horizontal gas–solid flows is very important to guarantee production efficiency and process control. However, gravity causes uneven particle distribution, which creates a strong nonlinear relationship between sensor signals and solid concentration. When particle distribution changes, a single linear measurement model cannot provide enough detection accuracy. This paper proposes an adaptive model matching strategy for solid concentration measurement in horizontal gas–solid flows by using array capacitive sensor. The array capacitive sensor works with two excitation modes. The concave-ring excitation mode collects particle distribution information, and the multi-electrode excitation mode obtains solid concentration. These two types of signals build a dynamic matching relationship between particle distribution features and measurement models. In detail, signals from concave-ring excitation are input into the BP-Adaboost algorithm to classify particle distribution states. Multiple linear measurement models between multi-electrode signals and solid concentration are built through K-means clustering. After recognizing the particle distribution type, the Euclidean distance is used to automatically select the corresponding measurement model. A 3D simulation model combining gas–solid two-phase flow and electrostatic field is set up to test the feasibility of the proposed measurement method. Laboratory experiments are also conducted to prove its reliability. The test results show that the method can adapt well to various particle distribution states. Within the solid concentration range of 0.34–14.08%, the average relative measurement error is 4.41%. This method effectively improves the measurement accuracy of solid concentration in horizontal gas–solid two-phase flow.