ALESSANDRA APRILE

Prof. ALESSANDRA APRILE

University of Ferrara, Departiment of Engineering, Italy
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2009 in Engineering Structures
Verified
Journal Article
Closed access
Luca PelàLuca Pelà
Luca Pelà
ALESSANDRA APRILEALESSANDRA APRILE
ALESSANDRA APRILE
Andrea BenedettiAndrea Benedetti
Andrea Benedetti

1 January 2013 in Construction and Building Materials
Verified
Journal Article
Closed access
Luca PelàLuca Pelà
Luca Pelà
ALESSANDRA APRILEALESSANDRA APRILE
ALESSANDRA APRILE
Andrea BenedettiAndrea Benedetti
Andrea Benedetti


30 June 2017 in International Journal of Architectural Heritage
Verified
Journal Article
Closed access
Luca PelàLuca Pelà
Luca Pelà
PRPere Roca
Pere Roca
ALESSANDRA APRILEALESSANDRA APRILE
ALESSANDRA APRILE
Mortar is of all masonry components the most difficult to be experimentally characterized in heritage buildings. This article investigates the possibility of combining different in-situ and laboratory minor destructive testing (MDT) techniques to assess the strength of mortar in historical brickwork. Lime mortar and clay brick walls were built in the laboratory and then tested in order to derive empirical correlation rules among three different MDT techniques: double punch test (DPT), helix pull-out test (HPT), and pin penetration test (PPT). The outcomes of this activity were used eventually to assess the mortar properties of an important historical heritage structure, Casa Puig i Cadafalch, located near Barcelona. The research is intended to promote the use of MDT in studies and conservation works on built cultural heritage by providing criteria for the evaluation of the strength of existing mortar with respectful sampling and testing techniques.

1 December 2001 in Journal of Structural Engineering
Verified
Journal Article
Closed access
ALESSANDRA APRILEALESSANDRA APRILE
ALESSANDRA APRILE
ESENRICO SPACONE
ENRICO SPACONE
SLSuchart Limkatanyu
Suchart Limkatanyu
This paper discusses the problem of predicting the stiffness, load capacity, and failure modes of RC members strengthened in bending with bonded steel or carbon-fiber–reinforced plastic thin plates. A critical issue of this strengthening technique is that, when the plate debonds, the load capacity suddenly drops and the failure mode is typically brittle. Because of the concrete cracking diffusion and the yielding of the steel rebars, a significant amplification of the bond stresses takes place at the beam-plate interface. Delamination occurs when the bond strength is reached locally. To properly describe and realistically predict the behavior of the strengthened beams, a displacement-based fiber beam model is used. Bond slip between the beam and the plate is included by assuming separate displacement fields in the beam and in the strengthening plate. The proposed model is used to confirm and investigate distinct failure modes observed in experimental investigations. The discussion is limited to shallow beams, where shear deformations are neglected.

1 October 2009 in Journal of Composites for Construction
Verified
Journal Article
Closed access
MPMonia Perrone
Monia Perrone
JBJoaquim António Oliveira de Barros
Joaquim António Oliveira de Barros
ALESSANDRA APRILEALESSANDRA APRILE
ALESSANDRA APRILE
A strengthening technique, combining carbon fiber-reinforced polymer (CFRP) laminates and strips of wet layup CFRP sheet, is used to increase both the flexural and the energy dissipation capacities of reinforced concrete (RC) columns of square cross section of low to moderate concrete strength class, subjected to constant axial compressive load and increasing lateral cyclic loading. The laminates were applied according to the near surface mounted technique to increase the flexural resistance of the columns, while the strips of CFRP sheet were installed according to the externally bonded reinforcement technique to enhance the concrete confinement, particularly in the plastic hinge zone where they also offer resistance to the buckling and debonding of the laminates and longitudinal steel bars. The performance of this strengthening technique is assessed in undamaged RC columns and in columns that were subjected to intense damage. The influence of the concrete strength and percentage of longitudinal steel bars on the strengthening effectiveness is assessed. In the groups of RC columns of 8 MPa concrete compressive strength, this technique provided an increase of about 67% and 46% in terms of column’s load carrying capacity, when applied to undamaged and damaged columns, respectively. In terms of energy dissipation capacity, the increase ranged from 40%–87% in the undamaged columns, while a significant increase of about 39% was only observed in one of the damaged columns. In the column of moderate concrete compressive strength (29 MPa), the technique was even much more effective, since, when compared to the maximum load and energy dissipation capacity of the corresponding strengthened column of 8 MPa of average compressive strength, it provided an increase of 39% and 109%, respectively, showing its appropriateness for RC columns of buildings requiring upgrading against seismic events.