Alessandro Bianchi

Dr. Alessandro Bianchi

Università Cattolica del Sacro Cuore, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Seminars in Vascular Surgery
Verified
Journal Article
Closed access
PDF file
ASA. Scalise
A. Scalise
ABAlessandro Bianchi
Alessandro Bianchi
CTC. Tartaglione
C. Tartaglione
EBE. Bolletta
E. Bolletta
MPM. Pierangeli
M. Pierangeli
GBG. Di Benedetto
G. Di Benedetto

1 September 2020 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
ABAlessandro Bianchi
Alessandro Bianchi
GVGiuseppe Visconti
Giuseppe Visconti
AHAkitatsu Hayashi
Akitatsu Hayashi
ASAngela Santoro
Angela Santoro
VLValentina Longo
Valentina Longo
MSMarzia Salgarello
Marzia Salgarello

1 July 2020 in Archives of Plastic Surgery
Verified
Journal Article
Open access
PDF file
GVGiuseppe Visconti
Giuseppe Visconti
ABAlessandro Bianchi
Alessandro Bianchi
AHAkitatsu Hayashi
Akitatsu Hayashi
ACAlessandro Cina
Alessandro Cina
GMGiulio Maccauro
Giulio Maccauro
MSMarzia Salgarello
Marzia Salgarello
The ability to directly harvest thin and superthin perforator flaps without jeopardizing their vascularity depends on knowledge of the microsurgical vascular anatomy of each perforator within the subcutaneous tissue up to the dermis. In this paper, we report our experience with ultrahigh-frequency ultrasound (UHF-US) in the preoperative planning of thin and superthin flaps. Between May 2017 and September 2018, perforators of seven patients were preoperatively evaluated by both ultrasound (using an 18-MHz linear probe) and UHF-US (using 48- and 70-MHz linear probes). Thin flaps (two cases) and superthin flaps (five cases) were elevated for the reconstruction of head and neck oncologic defects and lower limb traumatic defects. The mean flap size was 6.5×15 cm (range, 5×8 to 7.5×23 cm). No complications occurred, and all flaps survived completely. In all cases, we found 100% agreement between the preoperative UHF-US results and the intraoperative findings. The final reconstructive outcomes were considered satisfactory by both the surgeon and the patients. In conclusion, UHF-US was found to be very useful in the preoperative planning of thin and superthin free flaps, as it allows precise anticipation of very superficial microvascular anatomy. UHF-US may represent the next frontier in thin, superthin, and pure skin perforator flap design.

20 February 2022 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
GVGiuseppe Visconti
Giuseppe Visconti
AHAkitatsu Hayashi
Akitatsu Hayashi
ABAlessandro Bianchi
Alessandro Bianchi
Girolamo TARTAGLIONEGirolamo TARTAGLIONE
Girolamo TARTAGLIONE
RBRoberto Bartoletti
Roberto Bartoletti
MSMarzia Salgarello
Marzia Salgarello

28 September 2021 in Journal of Reconstructive Microsurgery
Verified
Journal Article
Closed access
PDF file
ABAlessandro Bianchi
Alessandro Bianchi
MSMarzia Salgarello
Marzia Salgarello
AHAkitatsu Hayashi
Akitatsu Hayashi
JYJohnson C.-S. Yang
Johnson C.-S. Yang
GVGiuseppe Visconti
Giuseppe Visconti
Background The lymphaticovenular anastomosis (LVA) has three components, lymphatics, venules, and anastomosis, and all of them influence the anastomotic pressure gradient. Although it has been demonstrated that venule flow dynamics has an independent impact on the outcomes regardless the degeneration status of lymphatic vessels, recipient venules (RV) have been mainly neglected in literature. Methods From January 2016 to February 2020, 232 nonconsecutive patients affected by extremity lymphedema underwent LVA, for a total of 1,000 LVAs. Only patients with normal-to-ectasic lymphatic collectors were included to focus the evaluation on the RV only. The preoperative collected data included the location, diameter, and continence of the selected venules, the expected number, the anastomoses configuration, and their flow dynamics according to BSO classification. Results The 232 patients included 117 upper limb lymphedema (ULL) and 115 lower limb lymphedema (LLL). The average size of RV was 0.81 ± 0.32 mm in end-to-end (E-E), 114 ± 0.17 mm in end-to-side (E-S), 0.39 ± 0.22 mm in side-to-end (S-E), and 0.76 ± 0.38 mm in side-to-side (S-S) anastomoses. According to the BSO classification, on a total of 732 RV, 105(14%) were backflow venules, 136 (19%) were slack, and 491 (67%) were outlet venules. Also, 824 (82%) were E-E, 107 (11%) were E-S, 51 (5%) were S-E, and 18 (2%) were S-S anastomoses. Conclusion Based on 1,000 LVAs with similar lymphatic characteristics, we propose our algorithm that may aid the lymphatic microsurgeon in the selection of RV and the consequent anastomosis configuration, in order of obtain the best flow dynamic through the LVA. This therapeutic study reflects level of evidence IV.

28 May 2020 in Aesthetic Plastic Surgery
Verified
Journal Article
Closed access
PDF file
GVGiuseppe Visconti
Giuseppe Visconti
Gianluca FranceschiniGianluca Franceschini
Gianluca Franceschini
ABAlessandro Bianchi
Alessandro Bianchi
LBLiliana Barone-Adesi
Liliana Barone-Adesi
GGGiorgia Garganese
Giorgia Garganese
MSMarzia Salgarello
Marzia Salgarello