Akitatsu Hayashi

Akitatsu Hayashi

Auto-generated profile, based on publicly available information

Akitatsu Hayashi

Lymphedema Center, Kameda Medical Center, Chiba, Japan

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Plastic and Reconstructive Surgery - Global Open
Verified
Journal Article
Open access
AHAkitatsu Hayashi
Akitatsu Hayashi
GGGuido Giacalone
Guido Giacalone
TYTakumi Yamamoto
Takumi Yamamoto
FBFlorence Belva
Florence Belva
GVGiuseppe Visconti
Giuseppe Visconti
MSMarzia Salgarello
Marzia Salgarello
Background: Identification and localization of functional lymphatic vessels are important for lymphaticovenular anastomosis. Conventional high-frequency ultrasound (CHFUS) has been reported to be useful for them, but it has some disadvantages. In this article, we present new capabilities of ultra high-frequency ultrasound (UHFUS) for imaging of the lymphatic vessels, which may overcome the weakness of CHFUS. Methods: Thirty unaffected extremities in 30 unilateral secondary lymphedema patients (13 upper limbs and 17 lower limbs) were examined. Identification of the lymphatic vessels using UHFUS and CHFUS were performed at 3 sites in each unaffected extremity. Number and diameter of the detected lymphatic vessels were compared between UHFUS and CHFUS groups. At the same time, new characteristics of the lymphatic vessels seen with UHFUS were investigated. Results: One hundred sixty-nine lymphatic vessels were detected with UHFUS, and 118 lymphatic vessels with CHFUS. The number of lymphatic vessels found in upper and lower extremities was significantly larger with UHFUS than with CHFUS. The diameter of lymphatic vessels found in upper and lower extremities was significantly smaller with UHFUS than with CHFUS. All lymphatic vessels that were detected in UFHUS were less likely to collapse when the transducer was against the skin of the examined sites. Conclusions: Detection rate of the lymphatic vessels in nonlymphedematous extremities with UHFUS was higher than that with CHFUS. UHFUS provides images with extremely high resolution, demonstrating new characteristics of the lymphatic vessels.

23 October 2017 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
PDF file
AHAkitatsu Hayashi
Akitatsu Hayashi
NHNobuko Hayashi
Nobuko Hayashi
HYHidehiko Yoshimatsu
Hidehiko Yoshimatsu
Takumi YamamotoTakumi Yamamoto
Takumi Yamamoto

8 April 2015 in Microsurgery
Verified
Journal Article
Closed access
PDF file
AHAkitatsu Hayashi
Akitatsu Hayashi
TYTakumi Yamamoto
Takumi Yamamoto
HYHidehiko Yoshimatsu
Hidehiko Yoshimatsu
NHNobuko Hayashi
Nobuko Hayashi
MFMegumi Furuya
Megumi Furuya
IKIsao Koshima
Isao Koshima

1 July 2020 in Archives of Plastic Surgery
Verified
Journal Article
Open access
PDF file
GVGiuseppe Visconti
Giuseppe Visconti
ABAlessandro Bianchi
Alessandro Bianchi
AHAkitatsu Hayashi
Akitatsu Hayashi
ACAlessandro Cina
Alessandro Cina
GMGiulio Maccauro
Giulio Maccauro
MSMarzia Salgarello
Marzia Salgarello
The ability to directly harvest thin and superthin perforator flaps without jeopardizing their vascularity depends on knowledge of the microsurgical vascular anatomy of each perforator within the subcutaneous tissue up to the dermis. In this paper, we report our experience with ultrahigh-frequency ultrasound (UHF-US) in the preoperative planning of thin and superthin flaps. Between May 2017 and September 2018, perforators of seven patients were preoperatively evaluated by both ultrasound (using an 18-MHz linear probe) and UHF-US (using 48- and 70-MHz linear probes). Thin flaps (two cases) and superthin flaps (five cases) were elevated for the reconstruction of head and neck oncologic defects and lower limb traumatic defects. The mean flap size was 6.5×15 cm (range, 5×8 to 7.5×23 cm). No complications occurred, and all flaps survived completely. In all cases, we found 100% agreement between the preoperative UHF-US results and the intraoperative findings. The final reconstructive outcomes were considered satisfactory by both the surgeon and the patients. In conclusion, UHF-US was found to be very useful in the preoperative planning of thin and superthin free flaps, as it allows precise anticipation of very superficial microvascular anatomy. UHF-US may represent the next frontier in thin, superthin, and pure skin perforator flap design.

1 May 2018 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
AHAkitatsu Hayashi
Akitatsu Hayashi
GVGiuseppe Visconti
Giuseppe Visconti
TYTakumi Yamamoto
Takumi Yamamoto
GGGuido Giacalone
Guido Giacalone
NHNobuko Hayashi
Nobuko Hayashi
MSMarzia Salgarello
Marzia Salgarello

17 March 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GGGuido Giacalone
Guido Giacalone
Takumi YamamotoTakumi Yamamoto
Takumi Yamamoto
FBFlorence Belva
Florence Belva
AHAkitatsu Hayashi
Akitatsu Hayashi
Identification of lymphatics by Indocyanine Green (ICG) lymphography in patients with severe lymphedema is limited due to the overlying dermal backflow. Nor can the method detect deep and/or small vessels. Multispectral optoacoustic tomography (MSOT), a real-time three- dimensional (3D) imaging modality which allows exact spatial identification of absorbers in tissue such as blood and injected dyes can overcome these hurdles. However, MSOT with a handheld probe has not been performed yet in lymphedema patients. We conducted a pilot study in 11 patients with primary and secondary lymphedema to test whether lymphatic vessels could be detected with a handheld MSOT device. In eight patients, we could not only identify lymphatics and veins but also visualize their position and contractility. Furthermore, deep lymphatic vessels not traceable by ICG lymphography and lymphatics covered by severe dermal backflow, could be clearly identified by MSOT. In three patients, two of which had advanced stage lymphedema, only veins but no lymphatic vessels could be identified. We found that MSOT can identify and image lymphatics and veins in real-time and beyond the limits of near-infrared technology during a single bedside examination. Given its easy use and high accuracy, the handheld MSOT device is a promising tool in lymphatic surgery.