Ana Amorim-de-Sousa

Ms. Ana Amorim-de-Sousa

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
LRLaura Remón
Laura Remón
Pablo Pérez-MerinoPablo Pérez-Merino
Pablo Pérez-Merino
RMRute J. Macedo-De-Araújo
Rute J. Macedo-De-Araújo
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
Bifocal and multifocal optical devices are intended to get images into focus from objects placed at different distances from the observer. Spectacles, contact lenses, and intraocular lenses can meet the requirements to provide such a solution. Contact lenses provide unique characteristics as a platform for implementing bifocality and multifocality. Compared to spectacles, they are closer to the eye, providing a wider field of view, less distortion, and their use is more consistent as they are not so easily removed along the day. In addition, contact lenses are also minimally invasive, can be easily exchangeable, and, therefore, suitable for conditions in which surgical procedures are not indicated. Contact lenses can remain centered with the eye despite eye movements, providing the possibility for simultaneous imaging from different object distances. The main current indications for bifocal and multifocal contact lenses include presbyopia correction in adult population and myopia control in children. Considering the large numbers of potential candidates for optical correction of presbyopia and the demographic trends in myopia, the potential impact of contact lenses for presbyopia and myopia applications is undoubtedly tremendous. However, the ocular characteristics and expectations vary significantly between young and older candidates and impose different challenges in fitting bifocal and multifocal contact lenses for the correction of presbyopia and myopia control. This review presents the recent developments in material platforms, optical designs, simulated visual performance, and the clinical performance assessment of bifocal and multifocal contact lenses for presbyopia correction and/or myopia progression control.

20 May 2018 in Eye and Vision
Verified
Journal Article
Open access
PDF file
António QueirósAntónio Queirós
António Queirós
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
DLDaniela Lopes-Ferreira
Daniela Lopes-Ferreira
CVCésar Villa-Collar
César Villa-Collar
ÁGÁngel Ramón Gutiérrez
Ángel Ramón Gutiérrez
JGJosé Manuel González-Méijome
José Manuel González-Méijome
To characterize the axial and off-axis refraction across four meridians of the retina in myopic eyes before and after Orthokeratology (OK) and LASIK surgery. Sixty right eyes with a spherical equivalent (M) between − 0.75 to − 5.25 D (cylinder <− 1.00 D) underwent LASIK (n = 26) or OK (n = 34) to treat myopia. Axial and off-axis refraction were measured with an open-field autorefractometer before and after stabilized treatments. Off-axis measurements were obtained for the horizontal (35° nasal and temporal retina) and vertical (15° superior and inferior retina) meridians, and for two oblique directions (45–225° and 135–315°) up to 20° of eccentricity. The refractive profile was addressed as relative peripheral refractive error (RPRE). OK and LASIK post-treatment results showed an increase of myopic relative refraction at several eccentric locations. At the four meridians evaluated, the M component of the pre-treatment RPRE values was not statistically different (p > 0.05) from the post-treatment RPRE within 30° and 20° of the central visual field after LASIK and OK, respectively. These results demonstrated that the treatment zone warrants an optimal central field of vision. The present study gives an overview of RPRE after refractive corneal reshaping treatments (OK and LASIK) across vertical, horizontal and two oblique meridians together. This allows a 3D representation of RPRE at the retina and shows that the myopic shift induced by both treatments is more relevant in horizontal directions.

6 November 2019 in Clinical and Experimental Optometry
Verified
Journal Article
Closed access
PDF file
António QueirósAntónio Queirós
António Queirós
DLDANIELA LOPES-FERREIRA
DANIELA LOPES-FERREIRA
BYBrigitte Yeoh
Brigitte Yeoh
SIStan Issacs
Stan Issacs
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
JGJosé González‐Méijome
José González‐Méijome

1 August 2018 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
Paulo FernandesPaulo Fernandes
Paulo Fernandes
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
António QueirósAntónio Queirós
António Queirós
SESantiago Escandón-Garcia
Santiago Escandón-Garcia
CMColm McAlinden
Colm McAlinden
JGJosé Manuel González-Méijome
José Manuel González-Méijome

2 August 2019 in Current Eye Research
Verified
Journal Article
Closed access
CMCatarina Martins
Catarina Martins
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
MFMiguel Faria-Ribeiro
Miguel Faria-Ribeiro
JPJaume Pauné
Jaume Pauné
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
António QueirósAntónio Queirós
António Queirós
Contact lenses (CLs) used for myopia control incorporate variable power distribution across the optic zone potentially creating degradation of the high-order aberrations. The present study aims to ...

1 April 2019 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
ARAlicia Ruiz-Pomeda
Alicia Ruiz-Pomeda
Paulo FernandesPaulo Fernandes
Paulo Fernandes
Ana Amorim-de-SousaAna Amorim-de-Sousa
Ana Amorim-de-Sousa
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
FPF.L. Prieto-Garrido
F.L. Prieto-Garrido
CCCésar Villa Collar
César Villa Collar