Lightning-induced backflashovers pose significant risks to high-voltage transmission systems, particularly in high lightning activity regions. Conventional backflashover rate (BFR) estimation methods rely on simplified empirical formulas that lack accuracy in complex scenarios. This paper presents a comprehensive simulation framework integrating (i) a Simulation-Based Leader Progression Model (SB-LPM) implemented in COMSOL Multiphysics–MATLAB to evaluate lightning attachment through detailed electrostatic field analysis and streamer-leader dynamics, (ii) ATP-EMTP electromagnetic transient simulations incorporating multi-component Heidler function current waveforms, calibrated to regional lightning measurements, and (iii) a Monte Carlo analysis for statistical assessment of backflashover susceptibility. Applied to a representative 138 kV transmission line in Minas Gerais, Brazil, the framework shows that BFR results are highly sensitive to tower-footing impedance and attachment model selection. The SB-LPM yields systematically different predictions compared to traditional electrogeometric models, yielding approximately 10% lower BFR estimates at 20 Ω grounding impedance relative to the widely used Eriksson model. The framework enables comprehensive lightning performance assessment by incorporating geometry-sensitive attachment modeling, realistic current waveform synthesis, and detailed system transient response, providing valuable insights for transmission line insulation coordination studies.
Electromagnetic radiation fields generated by return strokes transport both energy and momentum from the return stroke to outer space. The momentum transported by the radiation field has only a vertical or z component due to azimuthal symmetry (cylindrical symmetry) associated with a vertical return stroke. In this paper, the energy, momentum, and peak power radiated by return strokes as a function of the return stroke current, return stroke speed, and the zero-crossing time of the radiation fields are studied. The results obtained by numerical simulations for the energy, vertical momentum, and the peak power radiated by lightning return strokes (all parameters normalized by dividing them by the square of the radiation field peak at 100 km) are the following: A typical first return stroke generating a radiation field having a 50 μs zero-crossing time will dissipate field normalized energy of about (1.7–2.5) × 103 J/(V/m)2 and field-normalized vertical momentum of approximately (2.3–3.1) × 10−6 Kg m/s/(V/m)2. A radiation field with a zero-crossing time of 70 μs will dissipate about (2.6–3.4) × 103 J/(V/m)2 in field-normalized energy and (3.2–4.3) × 10−6 Kg m/s/(V/m)2 in field-normalized vertical momentum. The results show that, for a given peak radiation field, the radiated energy and momentum increase with increasing zero-crossing time of the radiation field. The normalized peak power generated by a first return stroke radiation field is about 1.2 × 108 W/(V/m)2 and the peak power is generated within about 5–6 μs from the beginning of the return stroke. Conversely, a typical subsequent return stroke generating a radiation field having a 40 μs zero-crossing time will dissipate field-normalized energy of about (6–9) × 102 J/(V/m)2 and field-normalized vertical momentum of approximately (7.5–11) × 10−7 Kg m/s/(V/m)2. The field-normalized peak power generated by a subsequent return stroke radiation field is about 1.26 × 108 W/(V/m)2 and the peak power is generated within about 0.7–0.8 μs from the beginning of the return stroke. In addition to these parameters, the possible upper bounds for the energy and momentum radiated by return strokes are also presented.
3 March 2026 in IEEE Transactions on Electromagnetic Compatibility
Estimating lightning disruptive effect (DE) in overhead transmission lines is crucial for insulation coordination and reliability assessment. However, conventional approaches, which usually rely on the Monte Carlo method, are computationally expensive, limiting their practical use. To overcome this limitation, this article proposes an approach that replaces part of the transient simulations with a machine learning (ML) algorithm, aimed at estimating the DE of direct lightning strikes. For this purpose, the ML algorithm is trained using samples randomly extracted from a dataset generated via an electromagnetic transients program-type, the alternative transients program (ATP), considering key input parameters, including current peak, phase angle at the moment of the strike, grounding impedance, and point of incidence along the line span. A Gaussian Process Regression model is adopted, as it naturally provides both the estimated value and its associated confidence interval. In the proposed approach, this aspect is exploited so that, if a prediction falls within a region of high uncertainty, an additional ATP simulation is executed to refine the result. The performance of the algorithm is computed using traditional metrics in the regression field. Its robustness is assessed by repeating multiple times the extraction of the samples to be used to train the ML algorithm and analyzing the related outcomes. The case study considered refers to four scenarios, differing in the soil resistivity and in the grounding impulsive impedance. According to results, the combination of the ML algorithm with the eventual additional ATP simulation allows obtaining accurate DE estimates and achieves average speedup of around 25 times.
Mountaintop towers are highly exposed to self-initiated upward lightning flashes. Accurate estimation of their effective height—the equivalent flat-ground height yielding the same lightning exposure—is essential for reliable exposure assessment, for interpreting and calibrating measurement data at instrumented mountaintop towers, and for comparison with established protection guidelines. This study applies a two-step numerical framework that couples finite-element electrostatic simulations with a leader-inception and propagation model for representative tower–terrain configurations reflecting reference instrumented mountaintop sites in lightning research. For each configuration, the stabilization field, the minimum background electric field enabling continuous upward leader propagation to the cloud base, is determined, from which effective heights are obtained. The simulated results agree with the analytical formulation of Zhou et al. (within ~10%), while simplified or empirical approaches by Shindo, Eriksson, and Pierce exhibit larger deviations, especially for broader mountains. A normalized analysis demonstrates that the tower-to-mountain slenderness ratio (h/a) governs the scaling of effective height, following a power-law dependence with exponent −0.17 (R2 = 0.94). This compact relation enables direct estimation of effective height from geometric parameters alone, complementing detailed leader-inception modeling. The findings validate the proposed physics-based framework, quantify the geometric dependence of effective height for mountaintop towers, and provide a foundation for improving lightning-exposure assessments, measurement calibration and design standards for elevated structures.