Antonio Jreije

Mr. Antonio Jreije

Physics Department, Kaunas University of Technology, Kaunas, Kauno Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
AJAntonio Jreije
Antonio Jreije
SMSwaroop Kumar Mutyala
Swaroop Kumar Mutyala
BUBenas Gabrielis Urbonavičius
Benas Gabrielis Urbonavičius
AŠAušrinė Šablinskaitė
Aušrinė Šablinskaitė
NKNeringa Keršienė
Neringa Keršienė
DADiana Adliene
Diana Adliene
There is a growing need to develop lead-free shielding materials that are safe, low weight, durable, environmentally friendly, chemically and mechanically stable and customizable for specific applications. Fused deposition modeling (FDM), an additive manufacturing technique based on the extrusion of a thermoplastic filament into a 3D printed object one layer at a time, could be employed well in applications involving ionizing radiation due to its relatively low cost, design flexibility and high manufacturing precision. This study aimed at developing 3D printing composites that contain Titanium dioxide as a filler agent for shielding in a medical radiation environment. First, the effect of low-dose ionizing radiation (up to 15 Gy) on the mechanical properties of common 3D printing polymers, ABS, ULTRAT, PLA, NYLON, ASA and PETG, was investigated. Since ABS experienced the lowest variation in its ultimate tensile strength (±5%) and Young’s modulus (−5%/+11%), it was chosen as a matrix for a new extruded 3D filament containing TiO2 at 1 wt.%, 3 wt.%, and 5 wt.%. With the incorporation of TiO2 at different filler contents, the UTS of the ABS composites varied between 24.1 MPa and 28.4 MPa, with the highest value recorded for 3 wt.% TiO2. Young’s modulus values were dependent on both the TiO2 concentration and on the irradiation dose. In addition, the ABS/TiO2 composites with a higher filler content (3 wt.% and 5 wt.%) maintained their attenuation ability even after exposure to a radiation dose of 100 Gy as opposed to pure ABS, which exhibited a ~2.5% reduction in its mass attenuation coefficient after exposure to the same dose of radiation. The pilot investigation performed demonstrated that the newly developed ABS/TiO2 composite containing 5 wt.% of filler can be successfully employed to shield electronic devices operating in a radiotherapy room.

17 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AJAntonio Jreije
Antonio Jreije
LKLalu Keshelava
Lalu Keshelava
Mindaugas IlickasMindaugas Ilickas
Mindaugas Ilickas
JLJurgita Laurikaitienė
Jurgita Laurikaitienė
BUBenas Gabrielis Urbonavičius
Benas Gabrielis Urbonavičius
DADiana Adliene
Diana Adliene
In radiation therapy, a bolus is used to improve dose distribution in superficial tumors; however, commercial boluses lack conformity to patient surface leading to the formation of an air gap between the bolus and patient surface and suboptimal tumor control. The aim of this study was to explore 3D-printing technology for the development of patient-specific conformal 3D-printed devices, which can be used for the radiation treatment of superficial head and neck cancer (HNC). Two 3D boluses (0.5 and 1.0 cm thick) for surface dose build-up and patient-specific 3D phantom were printed based on reconstruction of computed tomography (CT) images of a patient with HNC. The 3D-printed patient-specific phantom indicated good tissue equivalency (HU = −32) and geometric accuracy (DSC = 0.957). Both boluses indicated high conformity to the irregular skin surface with minimal air gaps (0.4–2.1 mm for 0.5 cm bolus and 0.6–2.2 mm for 1.0 cm bolus). The performed dose assessment showed that boluses of both thicknesses have comparable effectiveness, increasing the dose that covers 99% of the target volume by 52% and 26% for single field and intensity modulated fields, respectively, when compared with no bolus case. The performed investigation showed the potential of 3D printing in development of cost effective, patient specific and patient friendly conformal devices for dose verification in radiotherapy.

28 February 2024 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
AJAntonio Jreije
Antonio Jreije
NKNeringa Keršienė
Neringa Keršienė
PGPaulius Griskevicius
Paulius Griskevicius
DADiana Adliene
Diana Adliene

16 July 2025 in Polymers
Verified
Journal Article
Open access
PDF file
AJAntonio Jreije
Antonio Jreije
PGPaulius Griskevicius
Paulius Griskevicius
NKNeringa Keršienė
Neringa Keršienė
JLJurgita Laurikaitienė
Jurgita Laurikaitienė
RNRūta Nedzinskienė
Rūta Nedzinskienė
DADiana Adliene
Diana Adliene
The exponential growth of plastic production in the healthcare sector and the limited capacity of conventional recycling systems have created a global environmental challenge. Latest 3D printing technologies have the potential to solve this problem by enabling on-demand, localized manufacturing. This study aimed to investigate the mechanical properties of 3D-printed ABS composites with Bi2O3 fillers after multiple recycling and irradiation cycles to assess their suitability for creating robust, reusable supporting devices for radiotherapy. Filaments of PLA, ABS, and ABS composites enriched with 5 wt% and 10 wt% Bi2O3 were extruded, repeatedly recycled through shredding and re-extrusion up to ten times and irradiated to 70 Gy using a 6 MeV photon beam to simulate clinical radiotherapy conditions. In contrast to PLA, ABS demonstrated better recyclability; however, after ten recycling cycles, its tensile strength declined from 25.1 MPa to 20.9 MPa, and its Young’s modulus decreased from 2503.5 MPa to 1410.4 MPa. Incorporation of 5 wt% Bi2O3 into ABS significantly improved recyclability and mechanical retention. After ten recycling rounds, an ABS composite containing 5 wt% Bi2O3 retained tensile strength of 22.2 MPa, modulus of 1553.9 MPa, and strain at break of 14.4%. In contrast, the composite enforced with 10 wt% Bi2O3 showed slightly lower performance, likely due to filler agglomeration. Under irradiation, the ABS–5 wt% Bi2O3 composite exhibited minimal additional degradation, maintaining mechanical integrity superior to other materials. These results indicate that ABS–5 wt% Bi2O3 is a promising, recyclable material for durable, patient-specific devices in radiotherapy, supporting sustainability in medical manufacturing.

10 July 2024 in Journal of Radiological Protection
Verified
Journal Article
Open access
AJAntonio Jreije
Antonio Jreije
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė
BRBernardas Rimkus
Bernardas Rimkus
JDJūratė Dementavičienė
Jūratė Dementavičienė
KSKirill Skovorodko
Kirill Skovorodko
The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography. Dose quantities entrance surface dose, dose area product (DAP) and exposure parameters (kVp, mA, mAs) were measured and the effects on the images were evaluated, considering physical contrast to noise ratio (CNR) and observer-based evaluations as image quality metrics. Increasing the tube voltage by 5 kVp from standard protocol led to a reduction in radiation dose (DAP) by 12%–20% with a slight impact on image quality (CNR decreases by 2%–10%). There was an inter-observer variability in image rating across different equipment (kappa value between 0 and 0.3); however, both observers agreed that increasing kVp up to 85–90 kV had no effect on perceived image quality. The results indicate that optimisation strategies should be tailored specifically for each x-ray system since significant performance differences and wide variations in radiation dose exist across various digital radiography systems used in clinical settings. The use of high kVp can be used for dose optimisation in digital pelvis radiography without compromising image diagnostic accuracy.

23 February 2026 in Journal of Radiological Protection
Verified
Journal Article
Open access
AJAntonio Jreije
Antonio Jreije
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė
Computed tomography (CT) contributes disproportionately to medical radiation exposure. While most patients undergo only a few examinations, a subset accumulates high cumulative effective doses (CEDs), raising concern for long-term stochastic risks. Recently, the concept of a recurrent exposure reference level (RERL) has been proposed as a benchmark for cumulative dose monitoring in recurrently imaged patients. To evaluate cumulative radiation exposure from recurrent CT imaging in a tertiary care hospital, determine the proportion of patients exceeding high-dose thresholds, and establish a local RERL. All adult CT examinations performed at Vilnius University Hospital Santaros Klinikos between 2022 and 2024 were retrospectively analysed. Recurrent patients were defined as those with at least one CT in 2023 and an additional CT in 2022, 2023, or 2024. Outcome measures included the annual and three-year incidence and prevalence of CED ⩾ 100 mSv, dose distributions, and RERL determination as the 75th percentile of annual CED among recurrent patients. Over three years, 78 258 patients underwent 99 865 CT examinations. The annual number of patients and exams increased steadily, but the yearly incidence of high-dose patients (CED ⩾ 100 mSv) remained stable at ∼2%. Across the full cohort, 1633 patients (3.6%) exceeded 100 mSv, and 29 patients (0.04%) surpassed 500 mSv. Among 9199 recurrent patients (35.6% of the total), 18.2% exceeded 100 mSv within three years. Most patients (68%) crossed this threshold with fewer than five CTs. The local RERL, defined as the 75th percentile of annual CED in recurrent patients, was 36 mSv. A subset of patients in a tertiary care setting accumulated high radiation doses from recurrent CT, often with relatively few examinations. The derived RERL aligns closely with values reported in other European studies, supporting its use as a practical benchmark for monitoring cumulative dose. Systematic dose tracking, integration of RERLs, and strict adherence to justification and optimisation are essential to mitigate risks while preserving the diagnostic value of CT.