Kirill Skovorodko

Kirill Skovorodko

Auto-generated profile, based on publicly available information

Kirill Skovorodko

Vilnius University Hospital Santaros Klinikos, Vilnius, Lithuania

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Physica Medica
Verified
Journal Article
Closed access
KSKirill Skovorodko
Kirill Skovorodko
MBMilda Bareikė
Milda Bareikė
AGArūnas Gudelis
Arūnas Gudelis
BGBirutė Gricienė
Birutė Gricienė

2 August 2022 in Journal of Radiological Protection
Verified
Journal Article
Closed access
KSK Skovorodko
K Skovorodko
RKR Komiagienė
R Komiagienė
MMM Maciusovič
M Maciusovič
LGL Gilys
L Gilys
DVD Vajauskas
D Vajauskas
BGB Gricienė
B Gricienė
National diagnostic reference levels (DRLs) are essential tools for optimizing protocols and protecting patients from an unjustified radiation exposure. The aim of this study was to conduct a nationwide survey of adult patient doses received from nuclear medicine (NM) procedures and to update national DRL (NDRL) values for most common procedures. Data on the radioactivity administered to standard adult patients were collected from all Lithuanian hospitals using NM applications in practice, between 2017 and 2022. Twelve of the most commonly performed NM diagnostic procedures: myocardial perfusion scintigraphy (two parts), thyroid scintigraphy, lung perfusion scintigraphy, bone scintigraphy, dynamic renal scintigraphy (divided into two procedures), parathyroid scintigraphy, hepatobiliary scintigraphy, lymphoscintigraphy, neuroendocrine tumour scan, and oncology positron emission tomography/computed tomography (PET/CT) imaging were included. The 75th percentile of the dose distribution was estimated for establishing NDRLs. During the data collection period, the NM imaging equipment was upgraded. The procedures were completed with 12 single photon emission computed tomography (SPECT) and SPECT/CT gamma cameras (2 with cadmium zinc telluride (CZT) detectors), 2 cardiac-centred gamma cameras with CZT detectors, and 2 PET/CT scanners. Data were collected on 7979 activities administered to the patients. For each procedure, depending on its frequency, 50–580 administered radiopharmaceutical activities were selected. Based on the collected data, NDRLs were updated in 2021 for three procedures. A large part of the procedures were performed with scanners manufactured between 2008 and 2011. In the past few years, the main Lithuanian hospitals that provide NM services have updated their SPECT/CT systems. In the future, the data collection process should be continued in order to reassess DRLs with respect to new scanning systems (e.g. with CZT detectors and newer PET/CT technology). Variations in the prescribed radiopharmaceutical activities showed that optimization and harmonization procedures may be performed in some hospitals.

10 July 2024 in Journal of Radiological Protection
Verified
Journal Article
Open access
AJAntonio Jreije
Antonio Jreije
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė
BRBernardas Rimkus
Bernardas Rimkus
JDJūratė Dementavičienė
Jūratė Dementavičienė
KSKirill Skovorodko
Kirill Skovorodko
The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography. Dose quantities entrance surface dose, dose area product (DAP) and exposure parameters (kVp, mA, mAs) were measured and the effects on the images were evaluated, considering physical contrast to noise ratio (CNR) and observer-based evaluations as image quality metrics. Increasing the tube voltage by 5 kVp from standard protocol led to a reduction in radiation dose (DAP) by 12%–20% with a slight impact on image quality (CNR decreases by 2%–10%). There was an inter-observer variability in image rating across different equipment (kappa value between 0 and 0.3); however, both observers agreed that increasing kVp up to 85–90 kV had no effect on perceived image quality. The results indicate that optimisation strategies should be tailored specifically for each x-ray system since significant performance differences and wide variations in radiation dose exist across various digital radiography systems used in clinical settings. The use of high kVp can be used for dose optimisation in digital pelvis radiography without compromising image diagnostic accuracy.

1 September 2022 in Journal of Radiological Protection
Verified
Journal Article
Closed access
IAInga Andriulevičiūtė
Inga Andriulevičiūtė
KSKirill Skovorodko
Kirill Skovorodko
DADiana Adlienė
Diana Adlienė
ABAugustinas Bielinis
Augustinas Bielinis
JLJurgita Laurikaitienė
Jurgita Laurikaitienė
BGBirutė Gricienė
Birutė Gricienė
The hands of nuclear medicine (NM) personnel involved in radiopharmaceutical preparation and administration can receive significant radiation doses. The dose distribution across the hand is nonuniform and the Hp(0.07) doses obtained by an individual passive ring dosimeter do not always present a real situation. The aim of this study was to assess the extremity exposure of NM workers working with 99mTc-labelled radiopharmaceuticals and with an automatic IRIDE (COMECER, Italy) 18F-FDG injection system. Hp(0.07) doses were measured using calibrated thermoluminescent dosimeters-100 (TLD-100) and were read by a RIALTO TLD (NE Technology) reader. It was found that the most exposed parts of the hand during work with 18F and 99mTc radionuclides are the fingertips of the thumb, index finger and middle finger. The maximum fingertip doses were 1.3–2.4 times higher compared with the doses from the typical monitoring position (base of the middle finger of the dominant hand). When working with 99mTc, the average hand doses were relatively high, i.e. 0.17 ± 0.04 and 0.37 ± 0.13 mSv Gbq−1 for the left and the right hand, respectively, during preparation, and 58 ± 20 and 53 ± 13 µSv GBq−1 for the left and the right hand, respectively, during administration of 99mTc labelled radiopharmaceuticals. Meanwhile, the lowest doses were found for hands during administration of 18F-FDG (average hand dose 28 ± 13 µSv GBq−1 for the left hand and 28 ± 7 µSv GBq−1 for the right hand), which shows the advantages of automated injection/infusion systems, thus implementation of automatic infusion/injection in hospitals could be an expedient way to optimize Hp(0.07) doses to NM workers.

1 January 2024 in Medical physics – the current status, problems, the way of development. Innovation technologies
Verified
Journal Article
Open access
PDF file
KSKirill Skovorodko
Kirill Skovorodko
AJAntonio Jreije
Antonio Jreije
IAInga Andriulevičiūtė
Inga Andriulevičiūtė
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė
Introduction. Personal radiation protective equipment (PRPE) means such vests and skirts, aprons, thyroid collars and other means reduce radiation exposure of personnel working with X-rays and gamma ray sources. The composition of PRPE worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. In clinical practice, PRPEs with different lead equivalents are used. PRPE from lead or lead-equivalent material (LEM) are essential in providing necessary shielding from secondary radiation exposure to workers. Methods. Quality assessment of the PRPE was performed evaluating integrity and lead equivalence of more than 800 units, 0.25, 0.35, 0.5 and 1 mm LEM provided by ten manufacturers in the period 2022–2024. Results. Siemens Luminos dRF MAX 3D radiography, Philips Incisive CT computed tomography, Philips BV Endura mobile C-arm, and FLOWD 8020 mobile protective clothing testing X-ray units were used for obtaining images of PRPE for checking the integrity and lead equivalence. A calibrated solid-state meter Piranha R&F/M 657 with RTI Dose Probe was used for checking the radiation attenuation. In order to check the integrity, PRPE were categorized into four categories: I (good quality), II (small cracks), III (large cracks not in critical areas and smaller than 5 cm2), IV (very large cracks, cracks in critical areas, bigger than 5 cm2). PRPE lead equivalence deviations were analysed and grouped into three categories: DI (less than 5 %), DII (less than 10 %), DIII (more than 10 %). Conclusions. The results of the integrity tests showed that about 85 % of the PRPE were in good quality. The analysis of lead equivalence deviations showed that about 76 % of the PRPE met the criteria for category DI. The aim of the study was to evaluate the lead equivalence and the integrity of the PRPE used in clinical practice with different screening methods.

26 September 2023
Verified
Thesis
Closed access
KSKirill Skovorodko
Kirill Skovorodko
Application of dosimeters and calibrated ionization chambers in optimization of exposure in nuclear medicine procedures