Leonid Krynke

Mr. Leonid Krynke

Vilnius University Hospital Santariskiu Klinikos, Vilnius, Vilniaus Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2025 in Cancers
Verified
Journal Article
Open access
PDF file
EDEdvardas Danila
Edvardas Danila
LKLeonid Krynke
Leonid Krynke
ACAudrone Ciesiuniene
Audrone Ciesiuniene
EZEmile Zucenkiene
Emile Zucenkiene
Marius KantautasMarius Kantautas
Marius Kantautas
LVLina Venceviciene
Lina Venceviciene
Background/Objectives: In 2024, Lithuania developed a national lung cancer screening program (the Program), targeting individuals aged 50 to 70 years, regardless of their smoking history, with screenings conducted once every three years. The Program aims not only to actively detect lung nodules (lung cancer) but also to identify clinically significant concomitant findings. The pilot study aimed to evaluate the screening process’s feasibility and organizational efficiency of the screening process, as well as its potential clinical effectiveness. Methods: Three family medicine centers were selected for participation. The Coordinating Center contacted individuals aged 50 to 70 sequentially and invited them to participate, regardless of smoking status. In total, 1014 individuals were prospectively enrolled and underwent low-dose chest computed tomography (LDCT) screening between 26 September 2024 and 14 February 2025. Results: Of the individuals invited, 76.1% agreed to participate. Lung-RADS v2022 category 4 nodules were identified in 1.4% of participants (n = 14), including six smokers and eight non-smokers. Additionally, one participant with a Lung-RADS category 2 nodule was diagnosed with squamous cell carcinoma originating from peripheral lung changes. Newly identified significant incidental findings were detected in 25.9% of participants: 5.1% had pulmonary or mediastinal findings (most commonly emphysema, interstitial lung changes, and bronchiectasis), 18.7% had cardiovascular findings (usually coronary artery calcification, aortic valve calcification, and aorta dilation), and 2.1% had other clinically relevant conditions (e.g., thyroid nodules, diaphragmatic changes). Following assessment by family physicians, 17.6% of all participants were referred to medical specialists, including pulmonologists, cardiologists, and others. Conclusions: This pilot study demonstrated that the Lithuanian lung cancer screening model is feasible, well-organized, and clinically valuable. The findings support the Program’s readiness for broader implementation at the national level.

10 July 2024 in Journal of Radiological Protection
Verified
Journal Article
Open access
AJAntonio Jreije
Antonio Jreije
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė
BRBernardas Rimkus
Bernardas Rimkus
JDJūratė Dementavičienė
Jūratė Dementavičienė
KSKirill Skovorodko
Kirill Skovorodko
The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography. Dose quantities entrance surface dose, dose area product (DAP) and exposure parameters (kVp, mA, mAs) were measured and the effects on the images were evaluated, considering physical contrast to noise ratio (CNR) and observer-based evaluations as image quality metrics. Increasing the tube voltage by 5 kVp from standard protocol led to a reduction in radiation dose (DAP) by 12%–20% with a slight impact on image quality (CNR decreases by 2%–10%). There was an inter-observer variability in image rating across different equipment (kappa value between 0 and 0.3); however, both observers agreed that increasing kVp up to 85–90 kV had no effect on perceived image quality. The results indicate that optimisation strategies should be tailored specifically for each x-ray system since significant performance differences and wide variations in radiation dose exist across various digital radiography systems used in clinical settings. The use of high kVp can be used for dose optimisation in digital pelvis radiography without compromising image diagnostic accuracy.

1 January 2024 in Medical physics – the current status, problems, the way of development. Innovation technologies
Verified
Journal Article
Open access
PDF file
KSKirill Skovorodko
Kirill Skovorodko
AJAntonio Jreije
Antonio Jreije
IAInga Andriulevičiūtė
Inga Andriulevičiūtė
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė
Introduction. Personal radiation protective equipment (PRPE) means such vests and skirts, aprons, thyroid collars and other means reduce radiation exposure of personnel working with X-rays and gamma ray sources. The composition of PRPE worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. In clinical practice, PRPEs with different lead equivalents are used. PRPE from lead or lead-equivalent material (LEM) are essential in providing necessary shielding from secondary radiation exposure to workers. Methods. Quality assessment of the PRPE was performed evaluating integrity and lead equivalence of more than 800 units, 0.25, 0.35, 0.5 and 1 mm LEM provided by ten manufacturers in the period 2022–2024. Results. Siemens Luminos dRF MAX 3D radiography, Philips Incisive CT computed tomography, Philips BV Endura mobile C-arm, and FLOWD 8020 mobile protective clothing testing X-ray units were used for obtaining images of PRPE for checking the integrity and lead equivalence. A calibrated solid-state meter Piranha R&F/M 657 with RTI Dose Probe was used for checking the radiation attenuation. In order to check the integrity, PRPE were categorized into four categories: I (good quality), II (small cracks), III (large cracks not in critical areas and smaller than 5 cm2), IV (very large cracks, cracks in critical areas, bigger than 5 cm2). PRPE lead equivalence deviations were analysed and grouped into three categories: DI (less than 5 %), DII (less than 10 %), DIII (more than 10 %). Conclusions. The results of the integrity tests showed that about 85 % of the PRPE were in good quality. The analysis of lead equivalence deviations showed that about 76 % of the PRPE met the criteria for category DI. The aim of the study was to evaluate the lead equivalence and the integrity of the PRPE used in clinical practice with different screening methods.

14 December 2022 in Physica Medica
Verified
Journal Article
Closed access
KSKirill Skovorodko
Kirill Skovorodko
AJAntonio Jreije
Antonio Jreije
LKLeonid Krynke
Leonid Krynke
BGBirutė Gricienė
Birutė Gricienė

1 January 2024 in Medical physics – the current status, problems, the way of development. Innovation technologies
Verified
Journal Article
Open access
PDF file
BGBirutė Gricienė
Birutė Gricienė
LKLeonid Krynke
Leonid Krynke
MBMilda Bareikė
Milda Bareikė
AJAntonio Jreije
Antonio Jreije
KSKirill Skovorodko
Kirill Skovorodko
Introduction. Diagnostic and interventional X-rays represent a substantial portion of radiation exposure from artificial sources, with pediatric patients being particularly vulnerable due to their increased sensitivity to ionizing radiation. This study aimed at assessing radiation exposure in children undergoing interventional radiology (IR) procedures and computer tomography (CT) scans at Vilnius University Hospital Santaros Klinikos (VUHSK), Lithuania’s second-largest hospital, and to establish local Diagnostic Reference Levels (DRLs) to ensure optimized dose management. Methods. Data from pediatric IR and CT procedures conducted between 2021 and 2023 were analyzed, with local DRLs set at the 75th percentile of dose-related parameters such as Dose Area Product (DAP), Dose Length Product (DLP), Entrance Surface Dose (ESD), and Fluoroscopy Time (FT). Results. The findings reveal that pediatric CT doses at VUHSK are consistently below European DRLs, with reductions of up to 25 %, largely due to over a decade of ongoing patient exposure assessment and protocol optimization. Optimization efforts included adjustments to acquisition parameters. Despite the challenges of establishing separate local DRLs for each IR procedure due to limited sample sizes, age-based DRLs were developed to address the absence of routinely recorded patient weight. Conclusions. This study highlights the importance of continuous research in dose optimization and the need for local DRLs, especially for pediatric interventional radiology. The findings demonstrate that individualized optimization is crucial for maintaining low radiation doses without compromising diagnostic quality, and that establishing local DRLs is an essential step in ensuring patient safety.