Dump fires are a significant environmental problem in post-mining areas. The TEXMIN project has shown that climate change could lead to more extreme weather events in the future, intense precipitation among them. The impact of water erosion on the development of endogenous fires in coal waste heaps has not been investigated thus far. Meteorological data collected from the studied dump area in Libiaz, Poland confirmed that heavy rainfall occurred many times, causing surface erosion on the slope. Gully erosion was observed on the western slope of the heap, the depth of which was up to 1.6 m. Data showed that between areas with and without water erosion, there was a significant difference in measured temperatures and gas concentrations that defined the fire intensity. Erosion facilitated self-heating such that internal temperatures increased to 52.9 degrees C. Further, at a depth of 1 m in the self-heating zone, maximum gas concentrations were 15.65 vol%. CO2 , 10 ppm CO, and 0.435 vol%. CH4 , while the O-2 concentration dropped below 1.0 vol%. These results show that despite preventative measures, thermal activity reactivated in the vicinity of gully erosion and caused the self-heating zone to expand.
Reversal ventilation is one of prevention methods against fire hazard in underground mines, but it is not recommended for the mines where methane is present. The authors introduce the new method of reversal and by conducting numerical simulations they prove that it allows to keep methane at the acceptable level during miners escape. However, it requires connection between the subnetworks of the main ventilation fans. It was also shown, that by using the method some escape routes will be shortened. It is possible to apply this method in the mines where the fans and stoppings are fully controlled across the full range of their operating parameters. The findings are important for underground mines, as well as for surface facilities where air control or smoke control is managed by two or more fans.
The article presents the history of iron ore mining and production in present-day Poland and takes into account mining and production techniques and the influence of mining on the development of the surrounding areas. Examples of development are presented for the most important iron ore mining centers established since the period of the so-called Roman influences—Lower Silesia in the region of Tarchalice and the Świętokrzyskie region in the area of Góry Świętokrzyskie (Świętokrzyskie Mountains). The oldest traces of underground iron ore mining in Poland date back to the 7th–5th century B.C., and iron production dates back from the 1st century B.C. in the Częstochowa region where economically significant iron ore exploitation started in the 14th century and lasted until the 20th century. Studies showed that the development of iron ore mining in today’s Poland was associated with significant events in the country’s history, for example, with the expansion of a network of fortified castles in Silesia or with the industrial revolution. In each case, the increase in iron production resulted in the development and growth of the surrounding areas.
The occurrence of fire in road tunnels poses high risks to the life and health of people. The resulting smoke, fire gases and high temperatures can be the cause of poisoning and burns. Additionally, dense smoke can significantly reduce visibility, which can result in difficulties during evacuation. This paper aims to investigate the effect of specific wavelengths of visible light on visibility in smoke conditions and to determine the wavelength of light (colour) that can improve visibility in smoke-filled environments. A rubber mixture with polyester and polyamide spacers was selected as a combustible material in order to obtain more realistic conditions with respect to smoke parameters. These plastics are commonly used, among others, in tires, elements of engine plating, upholstery or truck trailer covers. Then, in a test fire chamber laboratory, the colour of light (wavelength) was determined, obtaining the highest transmittance value, understood as the amount of radiation transmitted through the substance. It has been shown that devices emitting a light wave of a specific length can significantly improve visibility in smoke-filled environment.
The article describes autoregressive one-day average and maximum methane concentration forecast models developed in Silesian University of Technology. In both presented autoregresive models, ex-post forecasts are performed based on linear equations with parameters estimated for each day of the week. As descriptive variable was used preceding day average methane concentration. As input data for research were used continuous methane measurement results and daily exploitation volumes from the one of Silesian coal mine longwalls and covers 152 days. Analyzed case study was carried out to check the accuracy of the forecasts for “Y” ventilated longwall. Such forecasts could be applied as a supporting tool for selection and adjustment of short-term methane prevention measures during exploitation.
The article presents the results of research into the influence of the location of auxiliary ventilation devices on the distribution of methane concentrations at the outlet of the longwall in an underground mine. Since this area is crucial from the point of view of explosion risk, the existence of an optimal arrangement of these devices could lead to improved safety of the crew working in the area. The aim of conducted study was to examine if the impact of this devices placement is significant. The research was carried out with the use of computational fluid dynamics (CFD) modeling—Ansys Fluent. The analyses took into account the location of the two most commonly used devices: a brattice and an auxiliary air-duct. The numerical model has been prepared and validated based on in situ measurements. Thirty-two cases of device configurations were analysed. The length and position of the brattice, as well as the height and position air-duct outlet along tailgate, were modified. It has been shown that although the presented solutions are an effective risk mitigation method, contrary to the common opinion of many practitioners, the impact of their exact placement, provided it is compliant with the regulations, is not significant for the registered methane concentration distribution at a longwall outlet.