Maria Magdalena Armendáriz-Ontiveros

Dr. Maria Magdalena Armendáriz-Ontiveros

Instituto Tecnológico de Sonora
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Desalination
Verified
Journal Article
Closed access
MAMaria Magdalena Armendáriz-Ontiveros
Maria Magdalena Armendáriz-Ontiveros
AGAlejandra Garcia-Garcia
Alejandra Garcia-Garcia
SVSergio de los Santos Villalobos
Sergio de los Santos Villalobos
Gustavo Fimbres WeihsGustavo Fimbres Weihs
Gustavo Fimbres Weihs

28 June 2019 in Materials
Verified
Journal Article
Open access
PDF file
MAMaria Magdalena Armendáriz-Ontiveros
Maria Magdalena Armendáriz-Ontiveros
YQYurieth Marcela Quintero
Yurieth Marcela Quintero
ALA. Llanquilef
A. Llanquilef
Mauricio J MorelMauricio J Morel
Mauricio J Morel
LML. Argentel Martínez
L. Argentel Martínez
AGAlejandra Garcia-Garcia
Alejandra Garcia-Garcia
The anti-biofouling and desalination properties of thin film composite reverse osmosis membranes (TFC-RO), modified by the incorporation of copper and iron nanoparticles, were compared. Nanoparticles of metallic copper (CuNPs) and an iron crystalline phase mix (Fe and Fe2O3, FeNPs) were obtained by oxide-reduction-precipitation and reduction reactions, respectively, and characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM) techniques. Modified membranes (PA+0.25Cu-PSL and PA+0.25Fe-PSL) were obtained by incorporating these nanoparticles during the interfacial polymerization process (PI). These membranes were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), atomic force microscopy (AFM), and contact angle measurements. Bactericidal tests by a Colony Forming Unit (CFU) were performed using Escherichia coli, and anti-adhesion properties were confirmed by fluorescence microscopy estimating the percentage of live/dead cells. The permeate flow and rejection of salts was evaluated using a crossflow cell. An increase of the membrane’s roughness on the modified membrane was observed, influencing the desalination performance more strongly in the presence of the FeNPs with respect to the CuNPs. Moreover, a significant bactericidal and anti-adhesion effect was obtained in presence of both modifications with respect to the pristine membrane. An important decrease in CFU in the presence of modified membranes of around 98% in both modifications was observed. However, the anti-adhesion percentage and reduction of live/dead cells were higher in the presence of the copper-modified membrane in comparison to the iron-modified membrane. These facts were attributed to the differences in antimicrobial action mechanism of these types of nanoparticles. In conclusion, TFC-RO membranes modified by the incorporation of CuNPs during PI represent one alternative material to attend to the biofouling impact in the desalination process.

30 November 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Bárbara RodríguezBárbara Rodríguez
Bárbara Rodríguez
MAMaria Magdalena Armendáriz-Ontiveros
Maria Magdalena Armendáriz-Ontiveros
RQRodrigo| Quezada
Rodrigo| Quezada
ESESTHER ALEJANDRA HUITRÓN SEGOVIA
ESTHER ALEJANDRA HUITRÓN SEGOVIA
HEHumberto Estay
Humberto Estay
AGAndreina Garcia
Andreina Garcia
The influence of the lateral size and the content of graphene oxide (GO) flakes in specific oxygenate functional groups on the anti-biofouling properties and performance of thin-film composite membrane (TFC) was studied. Three different multidimensional GO samples were prepared with small (500–1200 nm), medium (1200–2300 nm), and large (2300–3600 nm) size distribution, and with different degrees of oxidation (GO3 > GO2 > GO1), varying the concentration of the hydrogen peroxide amount during GO synthesis. GO1 sheets’ length have a heterogeneous size distribution containing all size groups, whilst GO2 is contained in a medium-size group, and GO3 is totally contained within a small-size group. Moreover, GO oxygenate groups were controlled. GO2 and GO3 have hydroxyl and epoxy groups at the basal plane of their sheets. Meanwhile, GO1 presented only hydroxyl groups. GO sheets were incorporated into the polyamide (PA) layer of the TFC membrane during the interfacial polymerization reaction. The incorporation of GO1 produced a modified membrane with excellent bactericidal properties and anti-adhesion capacity, as well as superior desalination performance with high water flow (133% as compared with the unmodified membrane). For GO2 and GO3, despite the significant anti-biofouling effect, a detrimental impact on desalination performance was observed. The high content of large sheets in GO2 and small sheet stacking in GO3 produced an unfavorable impact on the water flow. Therefore, the synergistic effect due to the presence of large- and small-sized GO sheets and high content of OH-functional groups (GO1) made it possible to balance the performance of the membrane.

1 September 2020 in Chemical Engineering Science
Verified
Journal Article
Closed access
MAMaria Magdalena Armendáriz-Ontiveros
Maria Magdalena Armendáriz-Ontiveros
JÁJ. Álvarez-Sánchez
J. Álvarez-Sánchez
Germán Eduardo Dévora-IsiordiaGermán Eduardo Dévora-Isiordia
Germán Eduardo Dévora-Isiordia
AGA. García
A. García
Gustavo Fimbres WeihsGustavo Fimbres Weihs
Gustavo Fimbres Weihs

20 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
MAMaria Magdalena Armendáriz-Ontiveros
Maria Magdalena Armendáriz-Ontiveros
Germán Eduardo Dévora-IsiordiaGermán Eduardo Dévora-Isiordia
Germán Eduardo Dévora-Isiordia
JRJorge Rodríguez-López
Jorge Rodríguez-López
RSReyna Guadalupe Sánchez-Duarte
Reyna Guadalupe Sánchez-Duarte
Jesús Álvarez-SánchezJesús Álvarez-Sánchez
Jesús Álvarez-Sánchez
MMMaría del Rosario Martínez Macías
María del Rosario Martínez Macías
Reverse osmosis (RO) desalination is considered a viable alternative to reduce water scarcity; however, its energy consumption is high. Photovoltaic (PV) energy in desalination processes has gained popularity in recent years. The temperature is identified as a variable that directly affects the behavior of different parameters of the RO process and energy production in PV panels. The objective of this study was to evaluate the effect of temperature on energy consumption and polarization factor in desalination processes at 20, 23, 26 and 30 °C. Tests were conducted on a RO desalination plant driven by a fixed 24-module PV system that received spray cooling in the winter, spring and summer seasons. The specific energy consumption was lower with increasing process feed temperature, being 4.4, 4.3, 3.9 and 3.5 kWh m−3 for temperatures of 20, 23, 26 and 30 °C, respectively. The water temperature affected the polarization factor, being lower as the temperature increased. The values obtained were within the limits established as optimal to prevent the formation of scaling on the membrane surface. The spray cooling system was able to decrease the temperature of the solar cells by about 6.2, 13.3 and 11.5 °C for the winter, spring and summer seasons, respectively. The increase in energy production efficiency was 7.96–14.25%, demonstrating that solar cell temperature control is a viable alternative to improve power generation in solar panel systems.

31 August 2022 in Membranes
Verified
Journal Article
Open access
PDF file
MAMaria Magdalena Armendáriz-Ontiveros
Maria Magdalena Armendáriz-Ontiveros
YVYedidia Villegas-Peralta
Yedidia Villegas-Peralta
JMJulia Elizabeth Madueño-Moreno
Julia Elizabeth Madueño-Moreno
Jesús Álvarez-SánchezJesús Álvarez-Sánchez
Jesús Álvarez-Sánchez
Germán Eduardo Dévora-IsiordiaGermán Eduardo Dévora-Isiordia
Germán Eduardo Dévora-Isiordia
TMTOMAS J. MADERA-SANTANA
TOMAS J. MADERA-SANTANA
Reverse osmosis (RO) desalination is a technology that is commonly used to mitigate water scarcity problems; one of its disadvantages is the bio-fouling of the membranes used, which reduces its performance. In order to minimize this problem, this study prepared modified thin film composite (TFC) membranes by the incorporation of chitosan–silver particles (CS–Ag) of different molecular weights, and evaluated them in terms of their anti-biofouling and desalination performances. The CS–Ag were obtained using ionotropic gelation, and were characterized by Fourier transform infrared spectroscopy (FTIR), high-resolution scanning electron microscopy (HR-SEM), energy-dispersive X-ray spectroscopy (EDX), thermogravimetric analysis (TGA) and dynamic light scattering (DLS). The modified membranes were synthetized by the incorporation of the CS–Ag using the interfacial polymerization method. The membranes (MCS–Ag) were characterized by Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and contact angle. Bactericidal tests by total cell count were performed using Bacillus halotolerans MCC1, and anti-adhesion properties were confirmed through biofilm cake layer thickness and total organic carbon (%). The desalination performance was defined by permeate flux, hydraulic resistance, salt rejection and salt permeance by using 2000 and 5000 mg L−1 of NaCl. The MCS–Ag-L presented superior permeate flux and salt rejection (63.3% and 1% higher, respectively), as well as higher bactericidal properties (76% less in total cell count) and anti-adhesion capacity (biofilm thickness layer 60% and total organic carbon 75% less, compared with the unmodified membrane). The highest hydraulic resistance value was for MCS–Ag-M. In conclusion, the molecular weight of CS–Ag significantly influences the desalination and the antimicrobial performances of the membranes; as the molecular weight decreases, the membranes’ performances increase. This study shows a possible alternative for increasing membrane useful life in the desalination process.