Arnaldo Batista

Prof. Dr. Arnaldo Batista

Faculdade de Ciências e Tecnologia, NOVA-FCT
+1
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2008 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
RRR.T. Rato
R.T. Rato
Manuel OrtigueiraManuel Ortigueira
Manuel Ortigueira
ABArnaldo Batista
Arnaldo Batista

1 February 2008 in Physics Letters A
Verified
Journal Article
Closed access
Manuel OrtigueiraManuel Ortigueira
Manuel Ortigueira
ABArnaldo Batista
Arnaldo Batista

25 November 2021 in Computers
Verified
Journal Article
Open access
PDF file
FCFilipa Cardoso
Filipa Cardoso
BFBeatriz Sereno Fernandes
Beatriz Sereno Fernandes
Valentina VassilenkoValentina Vassilenko
Valentina Vassilenko
ABArnaldo Batista
Arnaldo Batista
SRSara Russo
Sara Russo
Photoplethysmography (PPG) is widely used in wearable devices due to its conveniency and cost-effective nature. From this signal, several biomarkers can be collected, such as heart and respiration rate. For the usual acquisition scenarios, PPG is an artefact-ridden signal, which mandates the need for the designated classification algorithms to be able to reduce the noise component effect on the classification. Within the selected classification algorithm, the hyperparameters’ adjustment is of utmost importance. This study aimed to develop a deep learning model for robust PPG wave detection, which includes finding each beat’s temporal limits, from which the peak can be determined. A study database consisting of 1100 records was created from experimental PPG measurements performed in 47 participants. Different deep learning models were implemented to classify the PPG: Long Short-Term Memory (LSTM), Bidirectional LSTM, and Convolutional Neural Network (CNN). The Bidirectional LSTM and the CNN-LSTM were investigated, using the PPG Synchrosqueezed Fourier Transform (SSFT) as the models’ input. Accuracy, precision, recall, and F1-score were evaluated for all models. The CNN-LSTM algorithm, with an SSFT input, was the best performing model with accuracy, precision, and recall of 0.894, 0.923, and 0.914, respectively. This model has shown to be competent in PPG detection and delineation tasks, under noise-corrupted signals, which justifies the use of this innovative approach.

1 June 2022 in Symmetry
Verified
Journal Article
Open access
PDF file
FCFilipa Cardoso
Filipa Cardoso
ABArnaldo Batista
Arnaldo Batista
Valentina VassilenkoValentina Vassilenko
Valentina Vassilenko
SRSara Russo
Sara Russo
Manuel OrtigueiraManuel Ortigueira
Manuel Ortigueira
Heart Rate Variability (HRV) evaluates the autonomic nervous system regulation and can be used as a monitoring tool in conditions such as cardiovascular diseases, neuropathies and sleep staging. It can be extracted from the electrocardiogram (ECG) and the photoplethysmogram (PPG) signals. Typically, the HRV is obtained from the ECG processing. Being the PPG sensor widely used in clinical setups for physiological parameters monitoring such as blood oxygenation and ventilatory rate, the question arises regarding the PPG adequacy for HRV extraction. There is not a consensus regarding the PPG being able to replace the ECG in the HRV estimation. This work aims to be a contribution to this research area by comparing the HRV estimation obtained from simultaneously acquired ECG and PPG signals from forty subjects. A peak detection method is herein introduced based on the Hilbert transform: Hilbert Double Envelope Method (HDEM). Two other peak detector methods were also evaluated: Pan-Tompkins and Wavelet-based. HRV parameters for time, frequency and the non-linear domain were calculated for each algorithm and the Pearson correlation, T-test and RMSE were evaluated. The HDEM algorithm showed the best overall results with a sensitivity of 99.07% and 99.45% for the ECG and the PPG signals, respectively. For this algorithm, a high correlation and no significant differences were found between HRV features and the gold standard, for the ECG and PPG signals. The results show that the PPG is a suitable alternative to the ECG for HRV feature extraction.

12 January 2023 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
Manuel OrtigueiraManuel Ortigueira
Manuel Ortigueira
VMValeriy Martynyuk
Valeriy Martynyuk
VKVolodymyr Kosenkov
Volodymyr Kosenkov
ABArnaldo Batista
Arnaldo Batista
The mathematical description of the charging process of time-varying capacitors is reviewed and a new formulation is proposed. For it, suitable fractional derivatives are described. The case of fractional capacitors that follow the Curie–von Schweidler law is considered. Through suitable substitutions, a similar scheme for fractional inductors is obtained. Formulae for voltage/current input/output are presented. Backward coherence with classic results is established and generalised to the variable order case. The concept of a tempered fractor is introduced and related to the Davidson–Cole model.

1 September 2016 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ABArnaldo Batista
Arnaldo Batista
SNShirin Najdi
Shirin Najdi
DGDaniela M. Godinho
Daniela M. Godinho
CMCatarina Martins
Catarina Martins
FSFátima C. Serrano
Fátima C. Serrano
RRRaul T. Rato
Raul T. Rato