Astrid L. Giraldo-Betancur

Dr. Astrid L. Giraldo-Betancur

Consejo Nacional de Ciencia y Tecnología, Mexico City, Ciudad de México, Mexico
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2018 in Materials
Verified
Journal Article
Open access
PDF file
JRJuly Andrea Rincón-López
July Andrea Rincón-López
JHJennifer Andrea Hermann-Muñoz
Jennifer Andrea Hermann-Muñoz
Astrid L. Giraldo-BetancurAstrid L. Giraldo-Betancur
Astrid L. Giraldo-Betancur
AVAndrea De Vizcaya-Ruiz
Andrea De Vizcaya-Ruiz
JJuan Manuel Alvarado Orozco
Juan Manuel Alvarado Orozco
JSJuan Munoz Saldana
Juan Munoz Saldana
The physicochemical properties and biological behavior of sintered-bovine-derived hydroxyapatite (BHAp) are here reported and compared to commercial synthetic-HAp (CHAp). Dense ceramics were sintered for 2 h and 4 h at 1200 °C to investigate their microstructure–structure–in-vitro behavior relationship for both HAp ceramics. Densification was directly proportional to sintering time, showing a grain coarsening behavior with a greater effect on BHAp. Lattice parameters, crystallite size, cell volume and Ca/P ratio were determined by Rietveld refinement of X-ray diffraction (XRD) patterns using GSAS®. Ionic substitutions (Na+, Mg2+, CO32−) related to BHAp structure were associated with their position changes in the vibrational modes and correlated with the structural parameters obtained from the XRD analysis. Variations in the structural parameters and surface morphology were also evaluated after different soaking periods in simulated body fluid, which is associated with the formation of bone-like apatite layer and thus bioactivity. Mitochondrial activity (MTS) and lactate dehydrogenase (LDH) assays showed that the material released by the ceramics does not induce toxicity after exposure in human fetal osteoblastic (hFOB) cells. Furthermore, no statistically significant differences were found between the HAp obtained from different sources. These results show that BHAp can be used with no restrictions for the same biomedical applications as CHAp.

1 November 2020 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
JHJohn Henao
John Henao
OSOscar Sotelo-Mazon
Oscar Sotelo-Mazon
Astrid L. Giraldo-BetancurAstrid L. Giraldo-Betancur
Astrid L. Giraldo-Betancur
JBJuanita Hincapie Bedoya
Juanita Hincapie Bedoya
DEDiego G. Espinosa-Arbelaez
Diego G. Espinosa-Arbelaez
LMLorenzo Martinez-Gomez
Lorenzo Martinez-Gomez

1 January 2024 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
Carlos Poblano SalasCarlos Poblano Salas
Carlos Poblano Salas
JHJohn Henao
John Henao
Astrid L. Giraldo-BetancurAstrid L. Giraldo-Betancur
Astrid L. Giraldo-Betancur
PFPaola Forero-Sossa
Paola Forero-Sossa
Diego G Espinosa-ArbelaezDiego G Espinosa-Arbelaez
Diego G Espinosa-Arbelaez
IPIdelfonso E. Pech-Pech
Idelfonso E. Pech-Pech

3 October 2022 in Ceramics International
Verified
Journal Article
Closed access
PFP.A. Forero-Sossa
P.A. Forero-Sossa
JSJ.D. Salazar-Martinez
J.D. Salazar-Martinez
VBV.J. Barajas-Aguilar
V.J. Barajas-Aguilar
IOI.U. Olvera-Alvarez
I.U. Olvera-Alvarez
JHJ. Henao
J. Henao
Astrid L. Giraldo-BetancurAstrid L. Giraldo-Betancur
Astrid L. Giraldo-Betancur

29 November 2022 in Coatings
Verified
Journal Article
Open access
PDF file
PFPaola Andrea Forero-Sossa
Paola Andrea Forero-Sossa
Astrid L. Giraldo-BetancurAstrid L. Giraldo-Betancur
Astrid L. Giraldo-Betancur
Carlos Poblano SalasCarlos Poblano Salas
Carlos Poblano Salas
AGAixa Ibeth Gutierrez-Pérez
Aixa Ibeth Gutierrez-Pérez
EREsaú Moises Rodríguez-Vigueras
Esaú Moises Rodríguez-Vigueras
JHJohn Henao
John Henao
Low-pressure cold spray (LPCS) technology has attracted interest for the deposition of ceramic coatings due to the thermo-kinetic conditions experienced by the sprayed particles. Unlike conventional thermal spray techniques, the spraying conditions in LPCS can be controlled to avoid the formation of undesired phases. However, ceramics deposition through this process is still challenging. The present study includes a finite element analysis and simulation study of the kinetic conditions of ceramic particles in the LPCS process based on experimental data. The analysis seeks to discuss the effect of nozzle geometry on the kinetic and thermal energy of the sprayed particles at impact and elucidate how the particle travels within the high-velocity jet to be deposited onto a metallic surface. This work examines the behavior of hydroxyapatite particles as a function of particle size and nozzle geometry during LPCS deposition. Interestingly, the results from this research suggest that particle size and nozzle geometry have an influence on the deposition of hydroxyapatite particles. Inertia of large particles proved to be beneficial in keeping their trajectories, allowing them to contribute to the formation of the coatings. Nozzle geometry modifications produced changes in the jet profile and affected the homogeneity of the coatings obtained. This finding contributes to a better understanding of the deposition of hydroxyapatite particles by cold spraying.

2 September 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
HMHéctor Alexander López Muñoz
Héctor Alexander López Muñoz
JLJosé Mauricio López-Romero
José Mauricio López-Romero
MFMoises Armides Franco-Molina
Moises Armides Franco-Molina
AMAlejandro Manzano-Ramirez
Alejandro Manzano-Ramirez
MMMaría Cristina Velasquillo Martínez
María Cristina Velasquillo Martínez
GLGabriel Luna-Barcenas
Gabriel Luna-Barcenas
Herein, we report the synthesis of Au nanoparticles (AuNPs) in chitosan (CTS) solution by chemically reducing HAuCl4. CTS was further functionalized with glycidyl methacrylate (chitosan-g-glycidyl methacrylate/AuNP, CTS-g-GMA/AuNP) to improve the mechanical properties for cellular regeneration requirements of CTS-g-GMA/AuNP. Our nanocomposites promote excellent cellular viability and have a positive effect on cytokine regulation in the inflammatory and anti-inflammatory response of skin cells. After 40 days of nanocomposite exposure to a skin wound, we showed that our films have a greater skin wound healing capacity than a commercial film (TheraForm®), and the presence of the collagen allows better cosmetic ave aspects in skin regeneration in comparison with a nanocomposite with an absence of this protein. Electrical percolation phenomena in such nanocomposites were used as guiding tools for the best nanocomposite performance. Our results suggest that chitosan-based Au nanocomposites show great potential for skin wound repair.